6
4.
Technical specifications
Features
Douro
12 kW
Douro
17 kW
Douro
23 kW
Units
Weight
185
202
219
kg
Height
1110
1153
1215
mm
Width
617
595
663
mm
Depth
680
657
730
mm
Diameter of the fume discharge pipe
80
100
100
mm
Reservoir capacity
30
30
45
kg
Maximum heating capacity
295
391
502
m³
Maximum overall thermal power (water/air)
11,5 / 1,5
14,2 / 3
18,8 / 3,3
kW
Minimum thermal power (water/air)
3,8 / 1,2
4,3 / 0,8
4,3 / 0,8
kW
Minimum fuel consumption
1,1
1,1
1,1
kg/h
Maximum fuel consumption
1,5
3,9
5,1
kg/h
Rated electric power
100
134
134
W
Electric power at start-up (<10 min.)
406
434
434
W
Rated voltage
230
230
230
V
Nominal frequency
50
50
50
Hz
Thermal yield at rated thermal power
92,0
91,1
89,2
%
Thermal yield at reduced thermal power
95,0
93,8
93,8
%
Combustion gas flow (max.)
21,0
14,8
18,8
g/s
Combustion gas flow (min.)
44,0
6,9
6,9
g/s
Max. gas temperature
108
128
153
ºC
Min. gas temperature
62
66
66
ºC
CO emissions at rated thermal power
0,0136
0,02
0,02
%
CO emissions at reduced thermal power
0,0256
0,024
0,024
%
Draught in the chimney
12
12
12
Pa
Unit water volume
19
22
22
L
Draught in the chimney
49,1
49,1
49,1
dB(A)
Table 1 - Technical specifications
Tests performed using wood pellets with a heating capacity of 4,9 kWh/kg.
The above information was obtained during product homologation tests performed at independent
laboratories accredited for pellet unit tests.
Summary of Contents for Douro 12
Page 5: ......
Page 60: ...55 a b c d e f ...
Page 66: ...61 ...
Page 67: ...62 ...
Page 68: ...63 ...
Page 89: ...84 23 2 Flow chart Douro 12 kW Flow chart 1 Lighting ...
Page 90: ...85 ...
Page 91: ...86 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...
Page 92: ...87 23 3 Flow chart Douro 17 kW and Douro 23 kW Flow chart 1 Lighting ...
Page 93: ...88 ...
Page 94: ...89 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...