![SOLTRON Ergoline AFFINITY 700 (AC plus) Operating Instructions Manual Download Page 44](http://html1.mh-extra.com/html/soltron/ergoline-affinity-700-ac-plus/ergoline-affinity-700-ac-plus_operating-instructions-manual_1316987044.webp)
Cleaning and maintenance
42/78
7.8
Instructions for replacing the lamps
WARNING!
Danger of burns from hot lamps and device parts!
If the tanning device was operated before being switched off
and opened, lamps and housing parts may be hot.
–
Before replacing lamps or other spare parts, wait until
lamps and metal parts of the device have cooled down
sufficiently.
UV filters are used in order to control the UV radiation, e.g. the filter panels in
the facial tanner. However, the filter effect decreases over the course of time.
You must adhere to the replacement intervals specified in the maintenance
plan.
NOTE:
Small quantities of mercury can escape if the bulb/lamp
glass breaks!
Please comply with the following instructions:
Immediately disconnect the device from the mains pow-
er.
Children must leave the room immediately.
Ventilate the room for at least 15 minutes.
Put on disposable gloves.
With the window open: Collect the glass shards and
escaped mercury in a sealable container.
Bring the container to a collection site for waste lamps.