Delay
Adjusts the speed at which the welding filter returns to clear state once the welding process is over.
OPTIMATIC 50 models, the position SLOW the DELAY is 0,1s, and the position FAST the DELAY is
0,8s. For the OPTIMATIC 100 / 55 models the DELAY you can regulate from 0,1s to 1,0s.
Filter functions
For some filters ,two modes of operation can be selected : welding or grinding.
Grinding mode: Used for metal grinding applications. In this mode the shade function is turned off.
The shade is fixed in the light state that all owing a clear view to grind a weld with the helmet providing
face protection.
Welding mode: Used for most welding applications. In this mode the shade function is turned on.
When it optically senses a welding arc, please select a suitable shade level, delay time and sensitivity
as required.
PROTECTION LEVEL ADJUSTMENT
In case of having a filter with adjustable DIN to fit the degree according to the application of which we
are wanted to protect. To see the following table.
Grind mode is intended for Grinding not for welding.
Before restarting welding, the knob should be set back to the“ Weld ”position.
FILTERS SELECTION TABLE ACCORDING TO APPLICATION
CURRENT
IN AMPS
PLASMA
CUT
COATED
ELECTRO-
DES
MIG
HEAVY
IRONS
MIG
LIGHT
ALLOYS
TIG
MAG
ARC / AIR
PLASMA
WELD
0,25
TONE 8
TONE 8
TONE 2,5
0,5
TONE 3
0,75
TONE 4
1
TONE 5
2,5
TONE 6
5
TONE 7
10
TONE 8
15
TONE 8
TONE 9
TONE 9
20
TONE 10
30
TONE 9
TONE 10
40
TONE 11
60
TONE 11
TONE 10
TONE 11 TONE 9
80
TONE 12
100
TONE 11
TONE 10
TONE 12 TONE 10
125
TONE 11
150
TONE 11
TONE 13
TONE 11 TONE 10
TONE 13
175
TONE 12
200
TONE 12
TONE 12
TONE 12
TONE 12 TONE 11
225
250
TONE 13
TONE 14
TONE 13
TONE 12
TONE 14
275
TONE 13
300
TONE 13
350
TONE 13
TONE 13
TONE 14
400
TONE 14
TONE 14
450
500
TONE 15 TONE 15
TONE 15
TONE 14
TONE 14
TONE 15
SOLTER SOLDADURA S.L.