background image

7

 

Unattended:

 Do not leave the appliance unattended 

when in use.

 

Attachments:

 The use of attachments not 

recommended or sold by the manufacturer may cause 
fire, electric shock or injury.

 

Moving the appliance:

 When moving the 

Dehumidifier, always turn off and disconnect the 
power supply, and move it slowly.

 

Never place any objects containing liquid, such as 
flower vases or drinks, on top of the product.

 

Never handle the product with wet hands or  
while barefoot.

 

Switch off and unplug the product when it is not in use.

 

WARNING!

 If the product should tip over, immediately 

turn it off and unplug it.

 

Always maintain a 1m clearance around the 
Dehumidifier for any combustible materials or 
flammable gases. Do not place the appliance near  
a heat source.

 

WARNING!

 Never remove the water storage tank 

during operation.

 

Never drink the water captured within the 
Dehumidifier, it contains contaminants and may make 
you sick.

CLEANING AND MAINTENANCE

 

Disconnect: 

Make sure the appliance is disconnected 

from the power supply when it will not be used for a 
long time and before carrying out any cleaning  
or maintenance.

 

Air filter:

 Keep the air filter clean. Do not use the unit 

without the air filters fitted. Using it without air filters 
could cause an excessive accumulation of dust or 
waste on the inner parts of the device with possible 
subsequent failures.

 

Service and repair:

 The Dehumidifier has no  

user-serviceable parts contained inside. Do not 
attempt to disassemble, modify or conduct repairs on 
this unit. It has been built in accordance with relevant 
safety and performance standards. An electrical 
specialist must carry out all repairs. Contact our after 
sales support line for advice on service.

INSTALLATION

 

Proper installation:

 Install the appliance according 

to the instructions in this manual and national wiring 
regulations. Improper installation may result in the 
risk of fire, electric shock and/or injury. We assume no 
responsibility for any eventual damages caused by 
improper installation or faulty use.

 

Upright position:

 Place the unit on a flat surface to 

reduce the risk of it tipping over. Do not tilt the unit, 
always keep it upright. If the unit has not been kept 
upright (such as during storage), wait for at least  
24 hours before operation.

 

Obstructions:

 Do not locate the Dehumidifier where 

furniture or other objects can obstruct the airflow.

 

Do not cover:

 Do not cover the Dehumidifier or 

obstruct any air inlet or outlet grilles. Obstructing 
these openings causes a fire hazard, reduces the 
operating efficiency and may lead to malfunction or 
damage.

 

Chemicals:

 Do not install the Dehumidifier in 

environments where the air could contain gas, oil 
or sulphur. Do not let chemical substances come 
into contact with the unit. Do not use the unit in the 
presence of flammable substances or vapour such as 
alcohol, insecticides, petrol etc.

 

Heat: 

Do not install the Dehumidifier near sources  

of heat, or exposed to direct sunlight.

 

Room size:

 The unit is designed for use in a room  

of 29–44m² size.

 

Clearances:

 Always keep a clearance of at least 

100cm furniture and curtains and 20cm from walls. 
 

This symbol shows that this appliance uses a flammable refrigerant 
(R290). If the refrigerant is leaked and exposed to an external ignition 
source, there is a risk of fire.

Summary of Contents for GGSAD16W

Page 1: ...E S S E N T I A L S F O R L I F E User Manual MODEL GGSAD16W Dehumidifier...

Page 2: ...he following information which can be found on the rating plate and the date of purchase which can be found on your sales invoice STORE DETAILS STORE NAME ADDRESS TELEPHONE PURCHASE DATE PRODUCT DETAI...

Page 3: ...es and importantly taking care of your appliance when cleaning our Support Team are here to help You can use our online Support Centre at anytime by visiting http support residentiagroup com au or you...

Page 4: ...4 This page is intentionally left blank...

Page 5: ...ide 19 Other Useful Information 20 Technical Specifications 22 Warranty Information S lt recommends the use of original spare parts When contacting our customer service team please ensure that you hav...

Page 6: ...unplugging it from the wall socket Disconnect Turn off the unit first and then unplug it when it is not in use and before maintenance or cleaning but do not unplug it when it is in operation as this c...

Page 7: ...with relevant safety and performance standards An electrical specialist must carry out all repairs Contact our after sales support line for advice on service INSTALLATION Proper installation Install...

Page 8: ...he equipment manuf and repair requiring the assistance of other skilled personnel shall be carried of the person competent in the use of flammable refrigerants The appliance shall be stored in a room...

Page 9: ...inguisher adjacent to the charging area 6 No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained fla...

Page 10: ...d by the manufacturer Other parts may result in the ignition of refrigerant in the atmosphere from a leak 12 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibrati...

Page 11: ...volume liquid charge i Do not exceed the maximum working pressure of the cylinder even temporarily j When the cylinders have been filled correctly and the process completed make sure that the cylinder...

Page 12: ...er level indicator window 6 Drain hose outlet 7 Caster wheels 8 Power cord plug 9 Air intake grill 10 Air filter located behind the grill 11 Power cord storage Note The above diagrams are for explanat...

Page 13: ...after sales support line for advice Read the manual to familiarise yourself with all parts and operating principles Pay particular attention to the safety instructions on the previous pages WARNING EL...

Page 14: ...rcentage and conversely for damper air set a higher relative humidity level 5 Turbo button Fan Speed Use this button to select the fan speed Press to select either High or Normal fan speed setting Not...

Page 15: ...FEATURES Water tank full FULL This indicator light will illuminate when the water tank is full and ready to be emptied This light will also illuminate when the water tank has not been fitted correctl...

Page 16: ...ng the Timer setting to 0 0 will cancel the Auto Start or Auto Stop functions If the LED display window is showing the error code P2 the Auto Start or Stop function will also be cancelled Dryer Mode Y...

Page 17: ...he FULL indicator light will also flash and the digital display will show P2 Slowly and carefully remove the water tank Grip the left and right handles securely and carefully pull the tank straight ou...

Page 18: ...ing warm air in Close all windows and doors Have you allowed enough time for the appliance to work Is the room you are using the appliance in too large Room temperature is too low below 5 C The air fi...

Page 19: ...low the filter to completely dry before refitting it WARNING Never put the filter in a dishwasher or washing machine This will cause damage IMPORTANT Never operate the appliance without the air filter...

Page 20: ...20 RATING LABEL Technical Specifications...

Page 21: ...to the relevant label on the unit itself 2 Installation service maintenance and repair of this unit must be performed by a certified technician 3 Product uninstallation and recycling must be performe...

Page 22: ...epair an Appliance during the Warranty Period g Warranty Period means i where the Appliance is used for personal domestic or household use i e normal single family use as set out in the instruction ma...

Page 23: ...nce was serviced or repaired by anyone other than Residentia Group an authorised repairer or ASR 8 This warranty the contract to which it relates and the relationship between you and Residentia Group...

Page 24: ...C COM This a 6033 RESP At th prod of ina of it a facili T 1300 11 4357 E support residentiagroup com au E S S E N T I A L S F O R L I F E An initiative by Residentia Group www solt house...

Reviews: