56 User Manual UM0016_ASW 25K-40K-LT-G3_EN_V02_0622
Standby power loss
<12 W
Overvoltage category in
accordance with
IEC60664-1
III
Type
ASW33K-
LT-G3
ASW36K-
LT-G3
ASW40K-
LT-G3
Rated output power
33000W
36000W
40000W
Max. output apparent
power
36300VA
39600VA
44000VA
Rated AC Voltage (1)
3/N/PE
,
230/400V
AC voltage range
180V-305V/312V-528V
Rated AC Frequency (2)
50Hz/60Hz
Operating range at AC
power frequency 50 Hz
45Hz to 55Hz
Operating range at AC
power frequency 60 Hz
55Hz to 65Hz
Max. continuous output
current
52.6A
57.4A
63.8A
Maximum output current
under fault conditions
135A
Maximum output
overcurrent protection
100A
Adjustable displacement
power factor
0.80 ind - 0.80 cap
Inrush current (peak and
duration)
<13A @250us
Harmonic distortion
(THD) at the rated power
< 3%
Night-time power loss
<1 W
Standby power loss
<12 W