TIME LIMITS/MAINTENANCE CHECKS
05-20-00
SCHEDULED MAINTENANCE CHECK
October,
2011
Page 3
TABLE 1
CAMERA INSTALLED DAILY INSPECTION
NO. INSPECTION
ITEM
SIGN-
OFF
1
Camera Connections
– Verify that the camera cables are securely
connected to the camera.
2
Camera Security –
Verify that the dovetail locking blocks are
tightened in place and that the lock pin is installed.
Verify that the upper dovetail bolts are tight and safety wired.
Check the overall security of the installed camera pod.
3
Aileron Trim Tabs
– Verify that the left aileron trim tab is set from
0° to 9° up and the right aileron trim tab is set from 0° to 9° down.
Adjust trim tabs as required to correct for wing mount camera on
left wing. Trim tabs must be at equal but opposite angles. Also
verify both trim tabs are secured.
TABLE 2
CAMERA REMOVED DAILY INSPECTION
NO. INSPECTION
ITEM
SIGN-
OFF
1
Aileron Trim Tabs
– Verify both aileron trim tabs are set to 0° and
that the trim tabs are secured.
2
Wing Access Panel
– Verify that wing access cover installed at
wing access panel 510 YBS does not have a cable pass through
hole. Exchange panel for correct panel if the incorrect panel was
installed. Refer to Soloy document S2061A Cessna 206 with Wing
Mount Camera Illustrated Parts Catalog.