background image

MODEL

Plug   type

Capacity   (VA/W)

Input   Voltage

Voltage   range

Input   Frequency

Output   Voltage

Voltage   regulation

Output   Frequency

Frequency   regulation

Output   waveform

Battery   type

Recharge   time

Backup   time   @   120W

Transfer   Time

Audible   Alarm

Low   battery

Overload

Battery   replacement

Fault

Full   protection

Dimension   DxWxH   (mm)

Weight   (Kg)

Operating   environment

Noise   level

Fuse   type

Fuse   rating

Interfaces

UK

EU

UK

EU

UK

Built in power cord

Breaker

Built in power cord

Breaker

Built in power cord/Breaker

13A

7A

13A

7A

13A/10A

USB Type B x1 output

USB Type B x1 output

USB Type B x1 output

USB Type B x1 output

USB Type B x1 output

RJ11 x1 input, x1 Output

RJ11 x1 input, x1 Output

RJ11 x1 input, x1 Output

RJ11 x1 input, x1 Output

RJ45 x1 input, x1 Output

UK socket x 2 Output

EU socket x 2 Output

UK socket x 2 Output

EU socket x 2 Output

UK socket x 4 Output

UK plug x1 AC input

EU plug x1 AC input

UK plug x1 AC input

EU plug x1 AC input

UK plug x1 AC input

IEC socket x 1

IEC socket x 1

sounds every 2 seconds

4-6 hours recovery to 90% capacity

Typical 2-6 ms, 10 ms max.

650VA/360W

850VA/480W

220/230/240VAC

170-280Vac

51 or 60 Hz

  

 sounds every 10 seconds

 

Sounds every second

 

sounds every 0.5 second

220/230/240VAC

+/-10%

  

 +/-1 Hz

  

 50Hz or 60Hz

Modified Sine Wave

12V/9Ahx1

Ultima   LCD   650

Ultima   LCD   850

Ultima   LCD   1000

 

sounds every 0.5 second
sounds every 2 seconds

  

 continuously sounds

Overload, discharge, and overcharge protection

287 x 100 x 142

4-6 hours recovery to 90% capacity

Typical 2-6 ms, 10 ms max.

  

 sounds every 10 seconds

 

Sounds every second

  

 sounds every 10 seconds

 

Sounds every second

 

sounds every 0.5 second

Modified Sine Wave

12V/7Ahx2

4-6 hours recovery to 90% capacity

Typical 2-6 ms, 10 ms max.

1000VA/600W

220/230/240VAC

170-280Vac

52 or 60 Hz Auto sensing

220/230/240VAC

+/-10%

  

 50Hz or 60Hz

  

 +/-1 Hz

350 x 146 x 160

0-90% RH @ 0-40° C (non-condensing)

sounds every 2 seconds

  

 continuously sounds

Overload, discharge, and overcharge protection

10min

15min

30min

Less than 40 dB

220/230/240VAC

170-280Vac

50 or 60 Hz

220/230/240VAC

+/-10%

  

 50Hz or 60Hz

  

 +/-1 Hz

Modified Sine Wave

12 V/7 AH x 1

4.9

8

  

 continuously sounds

Overload, discharge, and overcharge protection

287 x 100 x 142

0-90% RH @ 0-40° C (non-condensing)

Less than 40 dB

4.25

0-90% RH @ 0-40° C (non-condensing)

Less than 40 dB

MODEL

Plug   type

Capacity   (VA/W)

Input   Voltage

Voltage   range

Input   Frequency

Output   Voltage

Voltage   regulation

Output   Frequency

Frequency   regulation

Output   waveform

Battery   type

Recharge   time

Backup   time   @   120W

Transfer   Time

Audible   Alarm

Low   battery

Overload

Battery   replacement

Fault

Full   protection

Dimension   DxWxH   (mm)

Weight   (Kg)

Operating   environment

Noise   level

Fuse   type

Fuse   rating

Interfaces

EU

UK

EU

UK

EU

Breaker

Built in power cord/Breaker

Built in IEC inlet 

Built in power cord/Breaker

Built in IEC inlet 

10A

13A/10A

10A

13A/15A

15A

USB Type B x1 output

USB Type B x1 output

USB Type B x1 output

USB Type B x1 output

USB Type B x1 output

RJ11 x1 input, x1 Output

RJ45 x1 input, x1 Output

RJ45 x1 input, x1 Output

RJ45 x1 input, x1 Output

RJ45 x1 input, x1 Output

EU socket x 4 Output

UK socket x 4 Output

EU socket x 4 Output

UK socket x 4 Output

EU socket x 4 Output

EU plug x1 AC input

UK plug x1 AC input

EU plug x1 AC input

UK plug x1 AC input

EU plug x1 AC input

Ultima   LCD   1500

Ultima   LCD   1000

1500VA/900W

220/230/240VAC

170-280Vac

53 or 60 Hz Auto sensing

220/230/240VAC

+/-10%

  

 sounds every 10 seconds

 

Sounds every second

 

sounds every 0.5 second

Modified Sine Wave

12V/7Ahx2

4-6 hours recovery to 90% capacity

Typical 2-6 ms, 10 ms max.

1000VA/600W

220/230/240VAC

170-280Vac

52 or 60 Hz Auto sensing

220/230/240VAC

+/-10%

  

 50Hz or 60Hz

  

 +/-1 Hz

4-6 hours recovery to 90% capacity

Typical 2-6 ms, 10 ms max.

  

 sounds every 10 seconds

350 x 146 x 160

397 x 146 x 205

0-90% RH @ 0-40° C (non-condensing)

0-90% RH @ 0-40° C (non-condensing)

sounds every 2 seconds

  

 continuously sounds

Overload, discharge, and overcharge protection

  

 50Hz or 60Hz

  

 +/-1 Hz

Modified Sine Wave

30min

40min

Less than 40 dB

 

Sounds every second

 

sounds every 0.5 second
sounds every 2 seconds

  

 continuously sounds

Overload, discharge, and overcharge protection

Less than 40 dB

12V/9Ahx2

8

11.1

Ultima   LCD   2000

2000VA/1200W

220/230/240VAC

170-280Vac

54 or 60 Hz Auto sensing

220/230/240VAC

+/-10%

  

 50Hz or 60Hz

  

 +/-1 Hz

 

sounds every 0.5 second
sounds every 2 seconds

  

 continuously sounds

Overload, discharge, and overcharge protection

397 x 146 x 205

11.5

0-90% RH @ 0-40° C (non-condensing)

Less than 40 dB

Modified Sine Wave

12V/9Ahx2

4-6 hours recovery to 90% capacity

42min

Typical 2-6 ms, 10 ms max.

  

 sounds every 10 seconds

 

Sounds every second

5. SPECIFICATION PANEL

162-290VAC

4

162-290VAC

Summary of Contents for Voltsure Ultima LCD 650

Page 1: ...tant This manual contains important safety instructions Keep this manual handy for reference Before using this product please read all instructions carefully Keep these instructions for future referen...

Page 2: ...rough supply from battery The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is neces...

Page 3: ...e UPS unit Connect from OUT outlet to the computer with phone line cable Connect Communication Cable Only for the model with USB port To allow for unattended UPS shutdown start up and status monitorin...

Page 4: ...Backup time 120W Transfer Time Audible Alarm Low battery Overload Battery replacement Fault Full protection Dimension DxWxH mm Weight Kg Operating environment Noise level Fuse type Fuse rating Interfa...

Page 5: ...wer cord Breake 10A 13A 10A USB Type B x1 output USB Type B x1 output RJ11 x1 input x1 Output RJ45 x1 input x1 Output EU socket x 4 Output UK socket x 4 Output EU plug x1 AC input UK plug x1 AC input...

Page 6: ...REAR PANEL 1000UK REAR PANEL 650 UK REAR PANEL 650 EU REAR PANEL 850 UK REAR PANEL 850 EU REAR PANEL 1000EU 6 REAR PANELS 6...

Page 7: ...KEY 1 Output receptacles 2 AC input 3 USB port 4 Modem Phone Network surge protection 5 Circuit breaker 6 IEC socket REAR PANEL 1500UK REAR PANEL 1500EU REAR PANEL 2000UK REAR PANEL 2000EU 7...

Page 8: ...charged state When storing batteries re charge every 6 months to prevent damage through self discharge This should be done more often if storage temperature exceeds 25 C Try to store use in a cool dr...

Reviews: