CSE-M53N User Manual Ver. 2.5
Sollae Systems Co., Ltd.
- 42 -
http://www.ezTCP.com
5.4
UDP
UDP has no connection processes. In this mode, data is sent in block units. Therefore,
data that comes through CSE-M53N’s serial port is collected in block units to send it
elsewhere.
5.4.1 Key parameters
Block Size(Byte)
[Block Size(Byte)] is to set the time to gather data in one block. Its unit is byte. If the
data in configured size of the [Block Size(Byte)] comes into the serial port, CSE-M53N
will send them as one block to the network. The maximum value could be 1460 bytes.
Dynamic update of Peer host
If you set the value of [Peer Address] and [Peer Port] to 0, [dynamic update of peer
host] function is activated. By using this function, CSE-M53N can communicate to
multiple hosts without additional setting.