background image

SCG-5608 User Manual Ver. 1.0 

 

 

- 14 - 

https://www.eztcp.com

 

 

 

 

Peer Port 

This item is to set the destination port number of the device for TCP connection 

and UDP data transmission. It can be set from 0 to 65535, and the default values 

are 14700 to 14707. 

3.2.3

 

Advanced 

 

Connection Timeout (Unit: sec) 

This item is to set a timeout for terminating a TCP connection. If there is no 

received data during the time set in this item, the TCP connection is terminated. 

The unit is seconds and can be set between 0 and 3600. Default value is 0 which 

means no termination on the TCP connection. 

 

Event Count[Byte] 

This item is to set the number of bytes for specific event operation for each 

connection mode. Default value is 0. 

Connection mode 

Value 

Operation 

TCP Server

 

Empty the serial receive buffer 

when a new TCP connection is made. 

otherwise 

(less than 1,024 is 

highly recommended) 

Send the data in serial receive 

buffer to TCP when a new TCP 

connection is  made. 

TCP Client 

Immediately and repeatedly try to 

connect to TCP. 

Otherwise 

(less than 1,024 is 

highly recommended) 

Try to connect to TCP when 

received byte count is equal or 

greater than this value. 

Send the data in serial receive 

buffer to TCP when a new TCP 

connection is  made. 

Connectionless 

(UDP) 

Does not specify the UDP outgoing 

packet size. 

Otherwise 

(less than 1,024 is 

highly recommended) 

Specify the UDP outgoing packet 

size to this value. 

Table 3-2 Event Count 

 

Option 

Item 

Description 

Default Value 

Secure(TLS) 

Enable/disable TLS function 

Disable 

TCP No Delay 

Enable/disable TCP No Delay function 

Disable 

RFC2217 

Enable/disable RFC2217 function 

Disable 

Send MAC ID 

Enable/disable sending MAC ID function 

Disable 

Table 3-3 Option 

 

Summary of Contents for SCG-5608

Page 1: ...Sollae Systems https www eztcp com 8 Port Console Server SCG 5608 User Manual Version 1 0...

Page 2: ...0 2 2 Connecting a Product 10 2 3 Searching Devices 10 2 4 Logging in 10 3 Settings 11 3 1 Network 11 3 1 1 Obtain an IP address automatically 11 3 1 2 Use a Static IP address 12 3 2 General 13 3 2 1...

Page 3: ...3 Timeout 25 4 4 Export Import Setting Values 26 4 5 Factory Reset 27 5 Technical Support and Warranty 28 5 1 Technical Support 28 5 2 Warranty 28 5 2 1 Free Repair Services 28 5 2 2 Charged Repair Se...

Page 4: ...server with 8 RS232 ports Users can remotely access 8 serial devices via this product 1 2 Features 8 RS232 ports Support TLS v1 2 Support frame delimiter function Support IPv6 Self developed O S Indus...

Page 5: ...ttps www eztcp com 8 8 on a local area network Figure 1 2 8 8 on a local area network Serial tunnelling on a local area network Figure 1 3 Serial tunnelling on a local area network 1 8 on the Internet...

Page 6: ...CP UDP IP ICMP ARP TELNET DHCP DNS mDNS TELNET COM Port Control Option RFC2217 TLS Security Password for Configuration Communication TCP Server TCP Client or UDP Additional Separator setting for packe...

Page 7: ...power is supplied through the PWR1 port or PWR2 port and it is not a problem to connect both ports at the same time PWR1 port The input voltage is DC 8 5V to 38V This port is interfaced with a 2 pole...

Page 8: ...s port is for administrative use only 1 5 4 Ethernet SIG 5608 provides 10 100Mbps Ethernet The pin assignment is as follows Figure 1 7 Ethernet LED of the Ethernet When a network is NOT connected Gree...

Page 9: ...GND Ground Required 6 RXD Receive Data IN Required 7 DSR Data Set Ready IN Optional 8 CTS Clear To Send IN Optional Table 1 2 RS232 pin assignment The DTR 2 pin is activated when this device is connec...

Page 10: ...s When the supplied power is stable PWR When the supplied power is NOT stable PWR When an IP address is NOT assigned LINK ACT When a network is connected with and IP address assignment LINK ACT When a...

Page 11: ...LAN cable or a USB cable In the case of using a LAN cable note that your PC and the product should be on the same local area network 2 3 Searching Devices Run spFinder on your PC and press the search...

Page 12: ...IP address automatically This product can automatically obtain an IP address by DHCP A DHCP server is required to use this Figure 3 1 Obtain an IP address automatically Select the Obtain an IP address...

Page 13: ...com 3 1 2 Use a Static IP address You can set a static IP address to this product Figure 3 2 Use a static IP address Select the Use static IP address Set the Local IP address Subnet mask Gateway IP a...

Page 14: ...ations Required Values TCP Server Passive Connection Local Port TCP Client Active Connection Peer Address Peer Port Connectionless UDP No connection Local Port Peer Address Peer Port Table 3 1 Connect...

Page 15: ...Server 0 Empty the serial receive buffer when a new TCP connection is made otherwise less than 1 024 is highly recommended Send the data in serial receive buffer to TCP when a new TCP connection is ma...

Page 16: ...s serial port settings and status information through TCP This feature allows remote communication of the status of RS232 control pins RTS CTS DTR DSR The counterpart should also support the RFC2217 t...

Page 17: ...4 Serial Port Parameter Option Default Value Serial Type RS232 RS232 Baudrate 1200 230400 19200 Parity NONE EVEN ODD MARK SPACE NONE Data Bits 8 7 required to use a parity bit 8 Stop Bits 1 2 1 Flow C...

Page 18: ...ave button 3 3 2 Certificate This is for reading a certificate stored in your product 3 3 3 spFinder These items are related to spFinder use Local search If this item is not checked you will not be ab...

Page 19: ...com Remote access If this item is checked the product can be connected from the remote network The port number for this connection is TCP 57457 For security this item is unchecked by default 3 3 4 Cl...

Page 20: ...ting the product with spFinder press the Status button to display this window When you open this window the spFinder connects to the product and keeps the connection until you close the window or time...

Page 21: ...Elapsed time since it boots up day hour min sec IPv4 Assigned IPv4 address Subnet Assigned subnet mask Gateway Assigned gateway IP address DNS Assigned DNS server IP address Table 4 1 Product Informa...

Page 22: ...ecting a TLS session UDP UDP mode Table 4 2 TCP IP STATE STATISTICS Item Description sio_rx Statistics of incoming data from the serial port net_tx Statistics of outgoing data to the TCP session net_r...

Page 23: ...you can upgrade it to the latest version Firmware can be upgraded online or manually via spFinder 4 2 1 Online Upgrade If you can access to the Internet by your PC the Firmware can be upgraded online...

Page 24: ...Manual Upgrade Download a Firmware file to your PC Search and connect to your product by spFinder Click Advanced Firmware Change menu Select to Manual upgrade on the Firmware Upgrade window Click Sel...

Page 25: ...until you close the window or time out While the connection is maintained other hosts cannot access the product using the spFinder Figure 4 4 Console 4 3 1 Output Tab This tab displays console messag...

Page 26: ...status information statistics of the product 4 3 2 FW Log Tab This tab displays the log message from Firmware 4 3 3 Timeout This is the timeout display function that appears in the upper right of the...

Page 27: ...values of the product as a file except for the password The Import setting values menu loads setting values from a file which is saved by the Export setting values menu Note that you need to click th...

Page 28: ...he password Follow the procedure below by checking the status of RUN LED 1 Press and immediately release the function button 2 Press the function button and keep the state more than 5 seconds 3 Once t...

Page 29: ...com en support qna php 5 2 Warranty 5 2 1 Free Repair Services For product failures occurring within 2 years after purchase Sollae Systems provides free repair services or exchange the product However...

Page 30: ...but not limited to cars planes trucks boats aircraft helicopters etc In the same way the SIG 5608 is not designed or intended or authorized to test develop or be built into applications where failure...

Page 31: ...ci re provenant de l utilisation ou de l incapacit pouvoir utiliser le bo tier SIG 5608 m me si Sollae Systems Co Ltd ou un de ses distributeurs a t inform de la possibilit de tels dommages Le bo tier...

Page 32: ...ction du bo tier SIG 5608 sans que la responsabilit de Sollae Systems Co Ltd et de ses distributeurs ne puissent tre mise en cause ni que le bo tier SIG 5608 puisse tre chang au titre de la garantie R...

Page 33: ...SCG 5608 User Manual Ver 1 0 32 https www eztcp com 7 Revision History Date Version Description Author 2022 08 26 1 0 1 Created Roy LEE...

Reviews: