CIE-M10 User’s Manual Ver. 1.1
Sollae Systems Co., Ltd.
- 39 -
http://www. eztcp.com
8
Serial Port
8.1
Introduction
CIE-M10 provides RS232↔TCP/IP conversion function along with input/output port monitor and
control function. Using this function, existing serial devices may be easily connected to the TCP/IP
network. Also, TCP server, TCP client, AT command emulation, UDP, and many other devices are
supported to provide various applications to the users.
8.2
Serial Communication Mode
CIE-M10 has 5 serial communication modes. The following chart is a brief explanation for each
communication mode
Communication
Mode
Protocol
Connection
Topology
Etc.
TCP Server
TCP
Passive
1:1
AT Command
TCP
Active
Passive
1:1
TCP Client
TCP
Active
1:1
UDP
UDP
-
1:N
Serial
Modbus/TCP
Modbus/
TCP
-
1:1
CIE-M10‟s I/O ports are
controlled through the serial
port with Modbus/TCP
Table 8-1 Communication Mode
8.3
TCP Server
T2S is the mode that CIE-M10‟s serial port operates as a server.
When TCP connection comes through previously designated [Local Port] from remote host, CIE-
M10 will accept TCP connection. When CIE-M10 accepts the connection, TCP connection is
established. After establishing connection, data that comes through serial port will be sent to the
remote host after TCP/IP process, and TCP/IP data that comes from the remote host will be sent
to the serial port after TCP/IP process to establish data communication.