31
E
Never try to repair or dismantle the unit yourself. Before calling for assistance, please check
the points below.
Problem
Possible cause
Solution
The unit does not
Has the power cord been disconnected?
Plug the power cord in a working
operate.
outlet.
Is the water tank full indicator flashing?
Empty the water tank and
The tank is full and/or in a wrong position. position correctly.
Is the room temperature above 35 °C or
The protective device is activated,
below 5 °C?
the unit can not be started.
The dehumidifying
Is the air filter clogged?
Clean the filter as instructed
function does not work.
under «Cleaning».
Is the air inlet or air outlet obstructed?
Remove any obstacle.
No air is discharged.
Is the air filter clogged?
Clean the filter as instructed
under «Cleaning».
Operation is noisy.
Is the unit tilted or unsteady?
Move the unit to a stable, sturdy
location.
Is the air filter clogged?
Clean the filter as instructed
under «Cleaning».
The display shows
L0
.
The humidity of the air is lower than 35%.
TROUBLE SHOOTING
This product contains fluorinated gases covered by the Kyoto Protocol
Chemical Name of the Gas
R134A
Global Warning Potential (GWP) of the Gas
1300
Please note that the dehumidification performance of your SOLIS EASY DRY COMPACT strongly depends
on room temperature and relative air humidity. The colder the air, the less moisture it is able to absorb.
Accordingly, the appliance will also be able to extract less moisture. To increase the dehumidification capacity,
it is recommended that the room be heated. Approximate figures are set out in the following table.
DEHUMIDIFICATION CAPACITY
APPROXIMATE DEHUMIDIFICATION CAPACITIES IN LITRES PER 24 HOURS
Room temperature
Relative air humidity
50% 60% 70% 80% 90%
5°C
0,5
0,8
1
1,2
1,5
10°C
0,5
1
1,5
3
4
15°C
1
1,5
3
5
8
20°C
2
4
8
10
12
25°C
4,5
8
11
13,5
15,5
30°C
8,5
11
14
17
19
35°C
10,5 14 17,5 20 22,5
Solis_EasyDryCompact-Betriebsanleitung.indd 31