C-SB Stagebox (option)
The C-SB is a Mic/Line input/output stagebox which can be located remotely from the Centuri chassis. It operates at
48KHz sample frequency and is a 14U high, 462mm deep, rack-mounted unit.
At the front of the rack are nine slots for plug-in cards: six slots for mic/line input cards; two slots for line output cards
and one for the CPU card.At the rear is an auto-ranging switch-mode power supply.This will accept input voltages from
100–240v without adjustment.The PSU units provide two un-switched mains outlets via IEC 6A shuttered sockets.A 2nd
power supply unit may be fitted to provide redundancy.
Each micamp input card provides 8 channels, therefore a C-SB rack may be fitted with from 8 to 48 mic inputs.The line
output card also provides 8 channels but also features 4 channels of GPI relay closure. The CPU card is fitted with a
headphone socket to allow local monitoring of sources and also provides four analogue outputs via a 25-way D-type
connector.These outputs are assigned from the console and may be used for additional analogue feeds such as talkback or
SLS.
Each mic input is provided with a split output.This output functions in the same way as the BMA circuit. (ie. post pad, limiter
and 26dB buffer but pre the variable gain stage).The split outputs are available on 25-way D-type male connectors.
Remote stageboxes are linked to the Centuri core using duplex SC fibre-optic cable
(1)
for the audio data and a separate
ethernet cable
(2)
for the control functions (gain, pad, filter etc.).The audio fibre links to a stagebox can be duplicated thus
creating audio redundancy for critical or on-air reliability. (Fibre Links for the Centuri rack should be specified at the time
of order).
The standard unit is fanless and so can be located within the live production area – subject to the following note.A low-
noise fan ventilation kit is available as an option.
Note:The stagebox racks are cooled by convection at the front of the rack.The air flow from bottom to top of the front panel
must not be obstructed in any way (cable guides are provided at each side to route cables away from the air intake).The air
temperature at the intake and at the rear PSU heatsinks MUST NOT exceed 30° Centigrade.
Special considerations need to be observed when fitting stageboxes into flight cases – refer to Appendix F.
(1)
The fibre optic cable is available in two types: for distances of up to 550m (multimode fibre) and distances of up to 2Km
(singlemode fibre).
(2)
The standard maximum limit for ethernet cable is 100m. For distances of over 100m ethernet repeaters may be needed.
Alternatively, the ethernet cable can be converted to fibre.This can then run the same distances as the audio fibre. Please
discuss specific requirements with SSL’s Project Engineering Department.
MORSE System (option)
The MORSE (MOdular Resource Sharing Engine) system provides a cost-effective, scalable solution for the sharing of local
or remote audio I/O and managing control data. The system is designed for on-air reliability and features optional
redundancy on all data links and fault tolerant proprietary software.
The system comprises a central router to which remote stageboxes and consoles may be connected via optical MADI links
to provide a resource sharing solution.Up to 24 individual links are available in the 3U version or 48 links in the 6U version.
The router is a 3U 19” rack unit. Stageboxes may be connected to the router and I/O can then be allocated to any C200
processor connected to the router. If resource sharing is not required, Stageboxes can be connected directly to the
processor.
Stageboxes can be 3U or 6U 19” rack units and each can be fitted with up to 56 channels of I/O. Plug-in modules are
available for mic, line,AES, MADI and SDI.A 2nd redundant power supply can be fitted to both the 3U and 6U versions.
Stageboxes are connected to the router or console using one or two duplex optical MADI links.
System Components
Section 4
Page 21
Summary of Contents for C200 routing guide
Page 1: ...Installation Guide ...
Page 2: ...C200 Installation Guide ...
Page 3: ...Solid State Logic Digital Broadcast Console Installation Guide Version 2 0 0 82S6PC2010C ...
Page 50: ...Page 46 C200 Installation Guide Gold is 1 9 times heavier than Lead ...
Page 74: ...C200 Installation Guide Page 70 4dBu 1 229V rms 0dBu 0 775V rms 6dBu 0 388V rms ...
Page 76: ...C200 Installation Guide Page 72 This page is blank intentionally ...