Page 1: ...Installation Guide ...

Page 2: ...C200 Installation Guide ...

Page 3: ...Solid State Logic Digital Broadcast Console Installation Guide Version 2 0 0 82S6PC2010C ...

Page 4: ...ww solid state logic com Solid State Logic All Rights reserved under International and Pan American Copyright Conventions C100 C200 C300 Centuri C SB StageBox NetBridge NiTech Solid State Logic and SSL are trademarks of Solid State Logic All other product names and trademarks are the property of their respective owners No part of this publication may be reproduced in any form or by any means wheth...

Page 5: ...ridge option 23 Script Tray option 25 Loudspeaker Shelf option 25 XGA Video Switcher 25 5 Installation 27 Connections 27 Earth Connection 27 Console Control 29 PSU Status 31 Sync 31 I O MicAmp Card 33 I O Analogue Card 33 I O Digital Card 35 I O MADI Card 35 GPI O Card 37 C SB Stagebox Wiring 39 Talkback and Oscillator 43 Phasescope and Meter Wiring 45 Appendices A Equipment Specifications 47 B Co...

Page 6: ...tem options Specifications and Physical dimensions Pinouts of standard connectors The information provided by this manual is relevant to all of the versions of the C200 The aspects of the C200 which can be customised frame size channel layout meter panel as examples will be fully documented in the Custom Specification information for a specific console The Custom Specification information which de...

Page 7: ...ional practice Installation Instructions Voltage Selection and Fusing Although the majority of SSL equipment uses auto ranging power supplies some sub systems have user selectable voltage inlets Always confirm that the input mains voltage range is set correctly before applying power Always isolate the mains supply before changing the input range setting If it is ever necessary to replace a blown m...

Page 8: ...n and Over Current Protection An external disconnect device switch is required for this equipment which must be installed according to current wiring regulations A detachable power cord if fitted to this equipment is a suitable disconnect device otherwise an approved disconnect switch is required the rating of which is defined in the product specification Appendix A and on the equipment itself An ...

Page 9: ... manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Instructions for Disposal of WEEE by Users in the European Union The symbol shown here which is on the product or on its packaging indicates that this product m...

Page 10: ...l C200 systems include on site commissioning by an SSL engineer This is usually expected to take from 2 to 4 days depending on system size configuration and options Large systems or consoles split for shipment may require an additional 1 2 days of commissioning time You will be contacted by your local SSL office or agent shortly before delivery to arrange a commissioning date Training Three days o...

Page 11: ...ate machine room A 19 equipment rack will need to be provided into which the Centuri Processor can be mounted Note when positioning the rack that cards are inserted into the Centuri Processor from both the front and the rear depending on function Clearance for access to cards must therefore be provided both in front of and behind the rack see page 10 for service clearance diagram NetBridge which i...

Page 12: ...lation Guide 736 1083 45 SECTION CENTRE SECTION MONITOR 1 8 9 16 17 24 25 32 33 40 41 48 427 640 1136 334 721 55 2835 48 Channel Footprint Side Profile Showing Service Access Display cards Connector Panels Power supplies ...

Page 13: ...ear of the desk The mains input power connector will be located on a separate panel This panel is usually positioned in a bay adjacent to the Centre Section nearest to the centre of the console but may vary due to console layout Cable sets are available in 10 16 20 25 48 and 80m standard lengths Sets longer than 16m are at additional cost Service Access Access to all major electronic assemblies wi...

Page 14: ...Page 10 C200 Installation Guide Centuri Processor Crate side view Showing Card Access C SB Crate side view Showing Card Access Dimensions in mm 592 270 15U 14U 270 462 270 Front Rear Front Rear ...

Page 15: ...annels will be fitted with two input connectors for the standard mains supply so if the same console is also fitted with PSU redundancy it will have four input leads The inrush current present when powering the console can be significant typically ten times the steady current so the use of slow or motor rated fuses circuit breakers is recommended NetBridge which is a separate 2U unit see page 23 i...

Page 16: ... 30 1 1 4 1 20 1 RATIO RANGE DLY FILTER GAIN DYNAMICS GATE IN COPY HF SPLIT MIC THR 600 20 RLS LOAD 50 1 ATT 900 20 0 10 OUT 350 4K 16K 20 G A T E C O M P R E S S 0 10 5 16 13 10 7 4 1 60 0 30 1 1 4 1 20 1 RATIO RANGE DLY FILTER GAIN DYNAMICS GATE IN COPY HF SPLIT MIC THR 600 20 RLS LOAD 50 1 ATT 900 20 0 10 OUT 350 4K 16K 20 G A T E C O M P R E S S 0 1 0 5 16 13 10 7 4 1 60 0 30 1 1 4 1 20 1 RATI...

Page 17: ...tted to the processor The Centre Section may optionally be specified with a 6 or 8 channel LCD phase scope and has additional space for mechanical meters Alternatively a range of custom meter configurations is possible these should be detailed at the time of order The console frame may be specified to have 19 wide sections for script space known as Producer s tables These can be fitted with either...

Page 18: ...or Crate Front View Centuri Processor Crate Rear View Access to PSUs Removable media drive DSP cards System Disk card I O Cards Mic or Digital Access to CPU card Front panel card GPI O card Routing Link card I O Cards Mic Analogue or Digital NB Cards shown are an example Configuration will vary according to specification 3 3V 5V 5 5V 15V 15V O I 5V 1 6 7 12 SPLIT OUTPUTS MIC INPUTS A SCSI A SCSI B...

Page 19: ...s Slot 6 Reserved for future expansion Slots 7 10 Can be a combination of additional DSP cards and or I O cards micamp cards digital or MADI cards to special order only Slot 11 Always fitted with the system disc card unless the dual redundant disc option is specified There rear of the processor has space for 12 plug in cards Note that these slots are numbered from right to left Slots 1 4 Available...

Page 20: ...T Solid State O X F O R D E N G L A N D DSP CARD SCSI A SCSI B SCSI B DISK CARD MACHINE CONTROL TIME CODE CONTROL SURFACE 1 CONTROL SURFACE 2 CONTROL SURFACE 3 5V 3V3 IN 1 OUT 1 IN 2 OUT 2 W CLK IN 3 OUT 3 IN 4 OUT 4 W CLK 909XN System Disk Card CPU Card Console Interface Card Routing Link Card DSP Card ...

Page 21: ...a terminal TTY A D F H Unused on C200 1 The ethernet connection is used for SSL control information it is not TCP IP protocol Do not combine with proprietary networks Standard ethernet repeaters can be used Centuri Console Interface Card The Centuri Processor is always fitted with one Interface card It must be fitted to the rear of the card cage next to the CPU card The card provides the connectio...

Page 22: ...9 60 GPI 9 16 1 8 25 32 17 24 AES EBU IN 9 16 1 8 25 32 17 24 AES EBU OUT 5V 1 6 7 12 SPLIT OUTPUTS MIC IN 1 12 A1 A1 ANALOGUE IN 1 24 ANALOGUE OUT 1 24 IN OUT WORD SYNC IN OUT AES SYNC Tx Rx Tx Rx LOCK A LOCK B MADI Analogue I O Card Digital I O Card MADI I O Card GPI I O Card Mic Input Card ...

Page 23: ...tes from 32kHz to 96kHz The connectors are all D 25 type females and mating connectors can be supplied as a cost option A breakout panel is available as an option for the 75Ω card this converts D 25 connectors to chassis BNC plugs and comes with 1m connecting looms These panels should be mounted behind the Centuri rack they cannot be remotely located because the linking cables are unbalanced Front...

Page 24: ...T 48V SIG OVER LOAD SELECT 48V SIG OVER LOAD SELECT 48V SIG OVER LOAD SELECT PUSH PUSH PUSH PUSH PUSH PUSH PUSH PUSH 48V SIG OVER LOAD SELECT 48V SIG OVER LOAD SELECT 48V SIG OVER LOAD SELECT 48V SIG OVER LOAD SELECT 48V SIG OVER LOAD SELECT 48V SIG OVER LOAD SELECT 48V SIG OVER LOAD SELECT 48V SIG OVER LOAD SELECT PUSH PUSH PUSH PUSH PUSH PUSH PUSH PUSH 48V SIG OVER LOAD SELECT 48V SIG OVER LOAD ...

Page 25: ... as an option Note The stagebox racks are cooled by convection at the front of the rack The air flow from bottom to top of the front panel must not be obstructed in any way cable guides are provided at each side to route cables away from the air intake The air temperature at the intake and at the rear PSU heatsinks MUST NOT exceed 30 Centigrade Special considerations need to be observed when fitti...

Page 26: ...land FUSE risk of fire use same type and rating IEC 127 250V 250V Ratings AC 50 60Hz Volts Amps 626755X4 90 125 1 2 0 9 195 255 0 6 0 5 10A T 5A T DATE INITIALS TESTED NetBridge Front View NetBridge Rear View NetBridge PSU Voltage Selection Voltage select switch shown in the 230V position Voltage select switch shown in the 115V position 230 230 115 ...

Page 27: ...d a console template to a secure website edit the configuration offline and then reload their profile prior to the production saving valuable setup time Parameters available for offline configuration include fader strip allocations channel names and type bus routing assignments processing order output options and fader grouping setup NetBridge requires access to the facility s internet service To ...

Page 28: ...Page 24 C200 Installation Guide MIC GN ETHER 1 ETHER 2 ETHER 3 ETHER 4 CTRL 3 CTRL 2 CTRL 1 TAB OUT USB Location Of Bellypanel USB Connectors ...

Page 29: ...luded If this feature is required then two switches SP momentary will need to be mounted externally See page 56 for the appropriate connector pinout Script Tray option The script tray is a movable transparent panel which fits over a channel bay It has rollers fitted to allow it to move along the length of the desk The script tray does not require modifications to the console and can be added to ex...

Page 30: ...OWER INDICATORS REMOTE POWER INDICATORS PSU 1 PSU 2 SERIAL 1 8 TERMINAL SERIAL 9 230 SSL TCP IP Model Serial No Solid State Logic Oxford England FUSE risk of fire use same type and rating IEC 127 250V 250V Ratings AC 50 60Hz Volts Amps 626755X4 90 125 1 2 0 9 195 255 0 6 0 5 10A T 5A T DATE INITIALS TESTED Chassis Bolt Chassis Bolt ...

Page 31: ...S MUST NOT BE FROM DIFFERENT PHASES OF A 3 PHASE SUPPLY b Connect the Centuri s IEC lead s to appropriate mains supply outlet s If a redundant PSU module is specified refer to the notes above for suitable supply provision The Centuri crate is also fitted with auto ranging power supplies which will accept mains voltages which range from 100 to 240V without adjustment c If specified do not connect a...

Page 32: ...URFACE 3 906XA SYNC VIDEO 3 VIDEO 2 VIDEO 1 ETHERNET SERIAL MIC GN ETHER 1 ETHER 2 ETHER 3 ETHER 4 USB CTRL 3 CTRL 2 CTRL 1 TAB OUT VIDEO 2 VIDEO 1 Control Surface Wiring Block Diagram CPU Card Control Card Console Connector Panel Monitor Connector Panel Front Panel cables x 2 XGA video lead RJ45 Ethernet lead ...

Page 33: ...he Centuri processor uses an RJ45 Ethernet network to communicate with the C200 console Stageboxes and NetBridge The console has a built in 4 way Ethernet repeater Connect the Ethernet lead between the Centuri CPU card and any of the four Ether sockets beneath the console If Netbridge is specified then a second RJ45 Ethernet lead will be supplied with the system This lead is connected between the ...

Page 34: ... OUTPUT OSC OUTPUT EXT T B MIC IN PUSH X2 X1 X3 D14 D15 D16 D17 D18 D19 D20 D12 D13 METER INPUTS PHASE SCOPE COMP PWR IND IN D10 D11 D6 D7 D8 D9 PHASE SCOPE D1 D2 D3 D4 D5 I O I O CONSOLE POWER INDICATORS REMOTE POWER INDICATORS PSU 1 PSU 2 Audio Connector Panel CPU Card Sync Input connector ...

Page 35: ... female to the console Note that the 9 way connector Remote Power Indicators is not used This connector was allocated for power indication from remote I O units which are no longer available Sync Source This section refers to the following supplied items Description SSL Part No qty Note Terminator plug 75Ω 32TKB7TC 1 BNC 75Ω TEE Adaptor 32TKU7CC 1 a Connect the source of black and burst or composi...

Page 36: ... MIC IN 1 12 A1 A1 ANALOGUE IN 1 24 ANALOGUE OUT 1 24 Micamp Input Card Analogue I O Card Split Output Connectors 25 pin D type female Microphone input Connector Varicon 56 way female Analogue Input Connector DL96 female Analogue Output Connector DL96 female ...

Page 37: ...f 904 The Analogue Card provides 24 circuits of electronically balanced input and output These circuits are accessed via Canon DL 96 way female connectors mating connectors are available to order Refer to Appendix C for the connector pinouts As is the case for the MicAmp cards added subsequently should be placed to the left of existing cards The default line up level for analogue I O is 0dBFS 18dB...

Page 38: ...EBU OUT IN OUT WORD SYNC IN OUT AES SYNC Tx Rx Tx Rx LOCK A LOCK B MADI Digital I O Card MADI I O Card Copper version AES EBU Output Connectors 25 pin D type female AES EBU Input Connectors 25 pin D type female MADI Link A BNC 75Ω MADI Link B BNC 75Ω MADI Word Sync BNC 75Ω AES Sync BNC 75Ω ...

Page 39: ...1metre D25 D25 interconnecting looms are provided This loom should not be extended beyond 1m as the signals are unbalanced pairs As in the case of the Analogue I O cards added subsequently should be placed to the left of existing cards Note When assigning digital card output channels as insert sends the routing system will automatically assign the same input channel number as the corresponding ret...

Page 40: ...Page 36 C200 Installation Guide GPI I O Card IN OUT 1 12 13 24 25 36 37 48 49 60 1 12 13 24 25 36 37 48 49 60 GPI GPI input Connectors 25 way D type Male GPI output Connectors 25 way D type Female ...

Page 41: ...ignals can be either latching or momentary this is individually assigned in software using the touch screen When set to momentary the input signal duration needs to be greater than 50mS Note When used for track arming and tally the tally must return to the same number input as the output signal ie the tally for GPI Out 1 will be on GPI In 1 The switch closure is by DIL relay Contact rating is 100V...

Page 42: ...io link LC Fibre i f 1a Network RJ45 Network RJ45 LC Fibre i f 1a control link Page 38 C200 Installation Guide IN 1 OUT 1 IN 2 OUT 2 W CLK IN 3 OUT 3 IN 4 OUT 4 W CLK 909XN Centuri Link Card Fitted with two links Fibre Link with UTP control link 100m max Redundant Fibre Link with fibre control link 100m C SB CPU Card With redundant Fibre Link TERMINAL NETWORK CH1 CH2 CH3 CH4 IN 3 OUT 3 IN 4 OUT 4 ...

Page 43: ...ounting 16 port switch is available as a cost option Longer fibre cables and or ruggedised OB cable using adaptor panels patch panels are options SSL is able to provide a range of fibre solutions although the facility may prefer to provide its own fibre installation Details of fibre installation options should be discussed with SSL s Project Engineering Department prior to the time of order For lo...

Page 44: ...A AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA E T H E R N E T V ID E O 3 V ID E O 2 S Y N C V ID E O 1 9 6 0 X A S E R IA L RS232 Diagnostics Cable RS232 Terminal Cable SSL Network TCP IP Network Internal Network External Network Maintenance Access NetBridge Installation Operational Access TCP IP ne...

Page 45: ...l which must be passed through any firewall and redirected as required although this is unlikely to cause any security concerns as it has 128bit Secure Socket Layer encryption For file transfer between the console and the CFS the user must be logged in at the console itself For file transfer between the CFS and another computer eg authorised freelance engineer or SSL support staff the user may log...

Page 46: ...GAIN EXT GAIN LEVEL LEVEL TRIM FREQUENCY TRIM Internal Mic External Mic in Analogue I O card C200 Console Talkback and Oscillator Block Diagram Oscillator Output External Mic Input and Talkback Mix Output connectors Connector Panels Talkback Output Osc Output Centuri Chassis External mic gain trim Internal mic gain trim ...

Page 47: ...g The gain of each mic signal can be independently adjusted Access to the trim controls is from beneath the console on the console interface panel The external mic input is via a 3 pin XLR female labelled Ext T B Mic In The mixed T B output is via a 3 pin XLR Male labelled Talkback Output Oscillator Connections The C200 console includes an inbuilt analogue oscillator The output is available on a m...

Page 48: ...CENTER L R RS LS 12 9 6 TEST 6 12 18 24 30 36 42 LEFT RIGHT Ø 50 30 20 10 0 5 5 30 20 10 0 10 15 L R C LF SL SR L R M MONO OSC T B O P OSC STATUS LOCK METER INPUTS PHASE SCOPE COMP PWR IND IN D6 D7 D8 D9 PHASE SCOPE Connector Panel Connector Panel Centuri Crate Centuri Crate Analogue I O card Analogue I O card Digital I O card Digital I O card 3 off AES EBU ccts 2 off analogue ccts 4 off AES EBU c...

Page 49: ...utions may be possible Cable connections to the meters and phasescope will need to be run between the Centuri and the Console Both balanced analogue and 110Ω digital cables may be necessary depending on configuration These cables are not supplied by SSL The MSD600C 5 1 phasescope has inputs for 6 digital signals 3 AES EBU pairs plus a serial diagnostic port The RTW 10830 has eight digital input si...

Page 50: ...Page 46 C200 Installation Guide Gold is 1 9 times heavier than Lead ...

Page 51: ...approximately Voltage Range 100 240 V AC only Current 48ch Maximum over voltage range 10 3 4 3 A Power Factor 0 95 approximately Fusing No user accessible fuses Noise Fanless Connectors Power in main backup Harting Modular 3 pin Network RJ45 100 baseT Control Surface 3M MDR high density 50 way female Video in 1 and 2 HD15 female Trackball out USB B female External USB in USB A female Phasescope si...

Page 52: ...Power Factor 0 95 approximately Fusing Thermal current trip No fuses 16 A each input Noise 75 dB A approximately Connectors Power in 1 and 2 IEC male Network RJ45 100 baseT Sync in BNC 75Ω analogue video Video out 1 2 and 3 HD15 female Serial 62 way HD D type female 9 way breakout lead supplied Control Surface 3M MDR high density 50 way female Machine Control 25 way D type male Timecode 25 way D t...

Page 53: ...tion 32 DSP no I O 45 W maximum Voltage Switch selectable 115 or 230 V AC only Current At 115V input 0 5 A At 230V input 0 2 A Fusing No external fuses Noise 50 dB A approximately Connectors Power in IEC male Network TCP IP RJ45 Network SSL RJ45 Terminal 9 way D type male Serial 62 way HD D type female 9 way breakout lead supplied Netbridge must be supported on rack shelves Do not rely on the rack...

Page 54: ...bles Weight Rack with single PSU unit 19 kg Each Mic input or Line output card 1 7 kg Additional PSU module 5 8 kg Heat Dissipation 380 W maximum with 48ch fitted Voltage Range 100 240 V AC only Current At voltage range 10 0 3 9 A maximum with 48ch fitted Fusing 6 3 T A 1 25 time delay Noise Fanless Connectors Mains supply in IEC male Mains supply output x2 IEC female 6A max total Network SSL RJ45...

Page 55: ... 8 1 2 3 4 5 6 7 8 Socket DL 96 Pin Varicon 56 pin Dimensions 29mm x 69mm Dimensions 22mm x 67mm A E R a k u DD L W e h p z KK B F S b l v EE M X r AA LL C H T w FF N Y s BB MM D J U c m x HH P Z f j t CC NN K V d n y JJ A E R a k u DD L W e h p z KK B F S b l v EE M X r AA LL C H T w FF N Y s BB MM D J U c m x HH P Z f j t CC NN K V d n y JJ 70 68 79 69 1 2 3 4 5 6 7 8 A B C D E F G H J K L M N P...

Page 56: ...ctor Plug Socket Plug Socket Plug Socket 1 5 15 6 10 11 Socket Viewed from wiring side Pin 1 LIVE Pin 2 n c Pin 3 NEUTRAL Earth contact is via Earth pin in the housing frame Note The inserts utilise crimped pins which are not removable Part SSL Part Number 3 way socket housing 32VAK3DC 40A Contact 32VAQXEX Connectors Viewed From Wiring Side Plug Socket 1 2 3 1 2 3 XLR 3 Pin Dimensions 19 x 60mm ap...

Page 57: ... only Notes RTW10830 1 Meter 1 input Left meter Input 1 14 Meter 1 input and Left meter 2 n c 15 Meter 2 input unused Input 2 3 Meter 2 input and Right meter 16 n c 4 Meter 3 input Right meter Input 3 17 Meter 3 input 5 n c 18 Meter 4 input unused Input 4 6 Meter 4 input 19 n c 7 Meter 5 input unused Input 5 20 Meter 5 input 8 n c 21 Meter 6 input unused Input 6 9 Meter 6 input 22 n c 10 Meter 7 i...

Page 58: ... n c 18 Meter 4 input unused AES EBU out 1 2 6 Meter 4 input 19 n c 7 Meter 5 input unused AES EBU in 7 8 20 Meter 5 input 8 n c 21 Meter 6 input unused AES EBU in 5 6 9 Meter 6 input 22 n c 10 Meter 7 input unused AES EBU in 3 4 23 Meter 7 input 11 n c 24 Meter 8 input unused AES EBU in 1 2 12 Meter 8 input 25 n c 13 n c Phase Scope Diagnostics and Control Location Audio belly panel Connector Typ...

Page 59: ...reen 4 n c 17 n c 5 n c 18 n c 6 n c 19 n c 7 n c 20 n c 8 n c 21 n c 9 n c 22 n c 10 n c 23 n c 11 n c 24 n c 12 n c 25 n c 13 n c OSC STATUS LOCK Location Audio belly panel Connector Type 25 way D type male pin Description Notes 1 Oscillator Lock A Link to pin 2 to mute oscillator 14 n c 2 Oscillator Lock B 15 n c 3 n c 16 n c 4 n c 17 n c 5 n c 18 n c 6 n c 19 n c 7 n c 20 n c 8 n c 21 n c 9 n ...

Page 60: ...5 way D type female pin Description Notes 1 0V 14 0V 2 n c 15 Video enable switch Pull low to activate 3 Video Tally LED 16 Keyboard Tally LED 4 LINK LED 17 Keyboard enable switch Pull low to activate 5 n c 18 n c 6 n c 19 n c 7 n c 20 n c 8 n c 21 0V 9 n c 22 5V 10 n c 23 n c 11 15V 24 Video 2 input enable Pull low to activate 12 0V 25 0V 13 n c ...

Page 61: ...nd switch 16 Rewind tally 4 Forward switch 17 Forward tally 5 Stop switch 18 Stop tally 6 Play switch 19 Play tally 7 Skip back switch 20 Skip back tally 8 Record switch 21 Record tally 9 Tach 1 22 Tach 2 10 Dir 1 23 Dir 2 11 n c 24 n c 12 n c 25 n c 13 n c Video Location Centuri CPU Card Connector Type HD15 female pin Description Notes 1 Red 2 Green 3 Blue 4 ID bit 5 n c 6 Red screen 7 Green scre...

Page 62: ...tor Type 25 way D type female pin Description Notes 1 in 1 14 in 1 2 in 1 gnd 15 in 2 3 in 2 16 in 2 gnd 4 in 3 17 in 3 5 in 3 gnd 18 in 4 6 in 4 19 in 4 gnd 7 unused 20 out 1 8 out 1 21 out 1 gnd 9 out 2 22 out 2 10 out 2 gnd 23 out 3 11 out 3 24 out 3 gnd 12 out 4 25 out 4 13 out 4 gnd ...

Page 63: ... 30 54 7 Rx Data H 3 24 10 48 17 38 31 55 3 Tx Data H 2 22 8 46 15 36 29 53 8 Tx Data L 4 25 11 49 18 39 32 56 4 0V 6 27 13 51 20 41 34 58 9 n c 5 0V 43 45 44 44 62 61 60 61 TTY A B C D F G H RS422 Location Audio belly panel Connector Type 9 way D type male pin Description Notes 1 0V 6 0V 2 Rx Data L 7 Rx Data H 3 Tx Data H 8 Tx Data L 4 0V 9 n c 5 0V TTY E RS232 Location Audio belly panel Connect...

Page 64: ...pe male pin Description Notes VU or PPM only Notes RTW10830 1 Meter 1 input Left meter Input 1 14 Meter 1 input and Left meter 2 n c 15 Meter 2 input unused Input 2 3 Meter 2 input and Right meter 16 n c 4 Meter 3 input Right meter Input 3 17 Meter 3 input 5 n c 18 Meter 4 input unused Input 4 6 Meter 4 input 19 n c 7 Meter 5 input unused Input 5 20 Meter 5 input 8 n c 21 Meter 6 input unused Inpu...

Page 65: ...3 21 9 22 4 7 20 8 5 18 6 19 6 4 17 5 Split Outputs 7 12 Location 908 Micamp Connector Type 25 way D type female Cct Hot Cold Screen Notes 7 24 12 25 Pin 13 unused 8 10 23 11 9 21 9 22 10 7 20 8 11 18 6 19 12 4 17 5 MIC In 1 12 Location 908 Micamp Connector Type Varicon 56 way female Cct Hot Cold Screen Notes 1 D K P All other pins unused 2 C J N 3 A E L 4 B F M 5 V Z d 6 U Y c 7 R W a 8 S X b 9 n...

Page 66: ...B3 C3 4 A4 B4 C4 5 A5 B5 C5 6 A6 B6 C6 7 A7 B7 C7 8 A8 B8 C8 9 D1 E1 F1 10 D2 E2 F2 11 D3 E3 G1 12 D4 E4 G2 13 D5 E5 G3 14 D6 E6 G4 15 D7 E7 F7 16 D8 E8 F8 17 L1 K1 J1 18 L2 K2 J2 19 L3 K3 H1 20 L4 K4 H2 21 L5 K5 H3 22 L6 K6 H4 23 L7 K7 J7 24 L8 K8 J8 C200 Installation Guide Page 62 Analogue I O Card 904 A1 A1 ANALOGUE IN 1 24 ANALOGUE OUT 1 24 ...

Page 67: ...2 1 9 2 0 2 7 2 8 5 6 13 1 4 2 1 2 2 2 9 3 0 7 8 1 5 1 6 2 3 2 4 3 1 3 2 IN OUT AES EBU In 1 8 9 16 17 24 25 32 Location 902 DIO Connector Type 25 way D type female Cct Hot Cold Screen Notes 1 24 12 25 Pin 13 unused 2 10 23 11 3 21 9 22 4 7 20 8 5 18 6 19 6 4 17 5 7 15 3 16 8 1 14 2 AES EBU Out 1 8 9 16 17 24 25 32 Location 902 DIO Connector Type 25 way D type female Cct Hot Cold Screen Notes 1 24...

Page 68: ...ut 11B 12 Output 12A 25 Output 12B 13 15V 450mA across all connectors C200 Installation Guide Page 64 GPI I O Card 907 IN OUT 1 12 13 24 25 36 37 48 49 60 1 12 13 24 25 36 37 48 49 60 GPI GPI Inputs 1 12 13 24 25 36 37 48 49 60 Location Centuri Relay card Connector Type 25 way D type male pin Description Notes 1 Input 1A 14 Input 1B 2 Input 2A 15 Input 2B 3 Input 3A 16 Input 3B 4 Input 4A 17 Input...

Page 69: ...1 7 CPU Card Console 1 5 6 9 5 1 9 6 NetBridge Diagnostic Cable Serial 1 8 RS232 Location Netbridge Rear panel Connector Type 9 way D type male pin Description Notes 1 Chassis 6 n c 2 Rx Data 7 n c 3 Tx Data 8 n c 4 n c 9 n c 5 0V Terminal RS232 Location Netbridge Rear panel Connector Type 9 way D type male pin Description Notes 1 DCD Data Carrier Detect 6 DSR Data Set Ready 2 Rx Data 7 RTS Reques...

Page 70: ...C200 Installation Guide Page 66 Resistor Colour Code Black 0 Brown 1 Red 2 Orange 3 Yellow 4 Green 5 Blue 6 Violet 7 Grey 8 White 9 ...

Page 71: ...the circuit 0V rather than the chassis In these cases it may be advantageous to disconnect the screen at this connection Note however that this practice will degrade the EMC performance Connecting to Unbalanced Equipment Connecting to unbalanced equipment can be much more problematic It is much more likely that earth and induced RF currents will become referenced to the audio 0V which will give ri...

Page 72: ...C200 Installation Guide Page 68 1 inch 25 4mm exactly 1m 3 3 roughly 1 mile 1 600m roughly 1Kg 2 2 Pounds roughly ...

Page 73: ...Relative Humidity Operating 20 to 80 Non operating 5 to 90 Max wet bulb 29 Deg C non condensing Vibration Operating 0 2 G 3 100Hz Non operating power off 0 4 G 3 100Hz Shock Operating 2 G 10mSec Max Non operating 10 G 10mSec Max Altitude Operating 0 to 3000 m above sea level Non operating 0 to 12000 m Appendix E Environmental Specification ...

Page 74: ...C200 Installation Guide Page 70 4dBu 1 229V rms 0dBu 0 775V rms 6dBu 0 388V rms ...

Page 75: ...r just below the rear heatsink Microphone cables must not obstruct the air intake To help ensure this a cable guide is provided down the sides of the rack Design Requirements for a Flightcase If a Stagebox is to be installed into a flight case the following requirements in addition to those above must be met to ensure adequate passive cooling otherwise user must install a forced ventilation kit Bo...

Page 76: ...C200 Installation Guide Page 72 This page is blank intentionally ...

Page 77: ...ead DL DL 24cct 25m 92DL2524 Lead DL DL 32cct 10m 92DL1032 Lead DL DL 32cct 15m 92DL1532 Lead DL DL 32cct 20m 92DL2032 Lead DL DL 32cct 25m 92DL2532 Processor Machine cables 25 way D type to 9 way D type RS232 10m 66C60002 RJ45 to 25 way D type RS232 10m 66C67206 9 way D type to 9 way D type RS422 10m 66C60007 Network Cables Ethernet RJ45 to RJ45 10baseT 0 5m pin pin 66C67207 Ethernet RJ45 to RJ45...

Page 78: ...D15 XGA 16m 66DN16V1 Lead Video HD15 XGA 20m 66DN20V1 Lead Video HD15 XGA 25m 66DN25V1 Lead Video HD15 XGA 48m 66DN48V1 BNC 75 Y piece 32TKU7CC BNC 75 Terminator 32TKB7TC Miscellaneous Hardware 39U Equipment Rack 57GQ4QA8 25 way D type Male to Female Cable 15m 66C90014 IEC Mains Lead 32VGL372 IEC Mains Lead US 32VGL3BN ...

Page 79: ...Appendix G Part Numbers Page 75 Notes ...

Page 80: ...C200 Installation Guide Page 76 More Notes ...

Reviews: