c100 HdS SnMp t
RApS
The standard ‘trap’ objects that are available for the C100 HDS system in V1.1/5 software are shown in the following table.
object
from
description
SSLC110Restarting
System
System restarting
SSLC110MemLow
System
Blackrock DSP card memory low
SSLC110DspReboot
System
A DSP device on the Blackrock DSP card has rebooted
SSLC110DspRebootFail
System
A DSP device on the Blackrock DSP card has failed to
reboot
SSLC110Psu1Fail
Processor
Blackrock processor PSU 1 failure
SSLC110Psu2Fail
Processor
Blackrock processor PSU 2 failure
sslC110PsuFanFail
Processor
Blackrock processor fan failure
SSLC110MainGfx1Fail
Console
Primary console TFT meter driver failure
SSLC110MainGfx2Fail
Console
Secondary console TFT meter driver failure
SSLC110LostTileComms
System
Lost Ethernet communication to the control surface
SSLC110ResumedTileComms
System
Recovered Ethernet communication with the control
surface
SSLC110Synclost
System
External (Video/AES) sync lost
SSLC110SyncReturned
System
External (Video/AES) sync recovered
SSLC110NowActiveInRedundantPair
System
Blackrock processor is now the active member of a
redundant pair
SSLC110NowDormantInRedundantPair
System
Blackrock processor is now the dormant member of a
redundant pair
SSLC110DiskStatusNotify
SBC
SBC system disk SMART status trap. This will be sent upon
receiving a SMART error from the system hard disks
SSLC110RaidStatusNotify
SBC
SBC RAID disk array status trap. This will be sent upon
receiving a change in status from the system RAID disk
array manager
C100 HDS Installation Manual
Section 4 – Appendices
|
Page 4-21
SNMP