tB out
Location:
Console Connector Panel
Connector Type:
XLR 3-pin male
Pin
Description
Notes:
1
Chassis (screen)
2
+ signal
3
– signal
c
onnectoR
p
inoUtS
c100 HdS c
onSoLe
C100 HDS Installation Manual
Section 4 – Appendices
|
Page 4-7
Connector Pinouts
Meter inputs – Analogue
Location:
Console Connector Panel
Connector Type:
25-way D-type male
Pin
Description
VU Meters Only
With RTW TM7
1
Circuit 1 input
+
Left VU meter
Input 1
14
Circuit 1 input
-
And Left VU meter
2
-
15
Circuit 2 input
+
-
Input 2
3
Circuit 2 input
-
16
-
4
Circuit 3 input
+
Right VU meter
Input 3
17
Circuit 3 input
-
And Right VU meter
5
-
18
Circuit 4 input
+
-
Input 4
6
Circuit 4 input
-
19
-
7
Circuit 5 input
+
-
Input 5
20
Circuit 5 input
-
8
-
21
Circuit 6 input
+
-
Input 6
9
Circuit 6 input
-
22
-
10
Circuit 7 input
+
-
Input 7
23
Circuit 7 input
-
11
-
24
Circuit 8 input
+
-
Input 8
12
Circuit 8 input
-
25
-