background image

INS-TSSHC-3DNPSB-16.7A-1209

6

Ambient temperature

The figures displayed above the word “AMBI-

ENT”  indicate  the  ambient  temperature,  ±  0.5 

degree.  Temperature  can  be  displayed  in  de-

grees Fahrenheit or Celsius (see “Display in de-

grees Fahrenheit/Celsius”).

Temperature set point

The figures displayed above the word “SET” in-

dicate the temperature set point. It can be dis-

played  in  degrees  Fahrenheit  or  Celsius  (see 

“Display in degrees Fahrenheit/Celsius”).
To adjust the set point, just 

press  down  the  right  but-

ton  to  increase  the  value, 

or  the  left  button  to  de-

crease  it.  Set  points  can 

be adjusted by increments 

of 1°F or 0.5°C. To quick-

ly  scroll  through  the  set 

point  values,  press  and 

hold down the button. The minimum set point is 

37°F (3°C), and the maxi mum set point is 86°F 

(30°C).
In Day mode, you can turn off the thermostat by 

lowering the set point below 37°F. The set point 

value displayed will be OFF, and heating system 

start up will be impossible.

Day mode and Night mode

The  thermostat  includes  a  Day  mode  and  a 

Night mode, both of them having their own in-

dependently adjustable and recorded set point. 

When switching from one mode to the other, the 

system  will  automatically  use  the  tempera ture 

set point corresponding to the Day/Night mode 

selected. The standard factory set point adjust-

ment is 68°F (20°C) for the Day mode, and 60°F 

(16°C) for the Night mode.
The  current  Day/Night 

mode  selection  is  indi-

cated  on  the  display  by 

the  Sun  or  Moon  icon.  In 

order  to  manually  switch 

from one mode to the oth-

er,  simulta neously  press 

down the two buttons and 

release them immediately.

Night mode timer

The Night mode features a timer that automati-

cally returns to the Day mode after a selectable 

time period. This timer allows the temporary use 

of a temperature set point. The standard factory 

adjustment of the timer is 8 hours. With this ad-

justment,  the  thermostat  automati cally  returns 

to  Day  mode  8  hours  after  being  switched  to 

the Night mode.
For  example,  if  you  want  a  night  temperature 

lower  than  the  day  temperature,  both  Day/ 

Night modes set points will first have to be set 

at  the  desired  temperatures.  Before  bedtime, 

the  Night  mode  temperature  set  point  will  be 

activated  by  switching  manually  to  the  Night 

mode. The timer is set for the duration of the 

night.  The  thermostat  will  automatically  return 

to the Day mode at the end of the night, and the 

Day mode temperature set point, which is high-

er, will become effective at this time.

+

-

+

-

+

-

+

-

Summary of Contents for TSSHC-3DNPSB-16.7A

Page 1: ...INS TSSHC 3DNPSB 16 7A 1209 User s guide For further information or to consult this guide on line please visit our Web site TSSHC 3DNPSB 16 7A Electronic thermostat www sshcinc com ...

Page 2: ...2 mounting screws and two 2 solderless connectors suitable for copper wires Before installing and operating this product the owner and or installer must read under stand and follow these instructions and keep them handy for future reference If these in structions are not followed the warranty will be considered null and void and the manu facturer deems no further responsibility for this product Mo...

Page 3: ...tat in a location where temperature measurements could be altered For example close to a window on an external wall or close to a door leading outside exposed directly to the light or heat of the Sun a lamp a fireplace or any other heat source close or in front of an air outlet close to concealed ducts or a chimney and in a location with poor air flow e g behind a door or with frequent air draft con...

Page 4: ...of the thermostat fron the mounting base by tilting it upward 5 Align and secure the mounting base to the connection box using the two screws sup plied 6 Reinstall the front part of the thermostat on the mounting base and tighten the screw at the bottom of the unit 7 Turn on the power 8 Set the thermostat to the desired setting see the following section Important you must activate the Fan mode whe...

Page 5: ...A 1209 5 3 Operation Ambient temperature Timer Modes Frost free Day Night Fan Automatic Heating power used indicator Temperature set point Button to decrease set point timer Button to increase set point timer Set point lock ...

Page 6: ...rom one mode to the other the system will automatically use the tempera ture set point corresponding to the Day Night mode selected The standard factory set point adjust ment is 68 F 20 C for the Day mode and 60 F 16 C for the Night mode The current Day Night mode selection is indi cated on the display by the Sun or Moon icon In order to manually switch from one mode to the oth er simulta neously ...

Page 7: ... and when the thermostat is in the Day mode you must manually return to the Night mode If you want to automatically return to the Night mode the Automatic mode must be selected Automatic mode The Automatic mode which is associated to the Night mode timer allows alternating be tween the Day Night modes and the two cor responding set points over a 24 hour period Once activated this mode allows an au...

Page 8: ...s and hold down the button NOTE If you set the timer to any value exceeding 23 hours it will be impossible to activate the Automatic mode and if it was activated the Automatic mode will be deactivated 3 Activate the Automatic mode by simultane ously pressing down the two buttons for at least 3 seconds The Automatic mode icon will appear If the Automatic mode was al ready activated the same procedu...

Page 9: ...heit or Celsius symbol will be displayed 3 When the adjustment is completed release the buttons and wait for 5 seconds to exit the adjustment function Fan mode When the thermostat is used to control a heat ing system equipped with a fan the Fan mode MUST be activated This mode prevents the system from continuously starting and stoping which could cause fan failure The Fan mode is by default deacti...

Page 10: ... ously press down the and buttons for more than 10 seconds until the Lock icon disap pears 6 Release the buttons The thermostat is now unlocked NOTE If the thermostat isn t unlocked within 5 minutes after the restoration of the power sup ply the Lock icon will stop to blink and it will be impossible to unlock the thermostat unless cut ting off the power supply again Heating power indicator The lev...

Page 11: ...ircuit breaker and intervening switches performance 5 The display turns off a few minutes and then turns on again The thermal protection of the heating unit has deactivated the unit due to overheating Check if the heating unit is in good condition of operation and that clearance around the appliance is according to the manufacturer s specifications 6 The display has low contrast when heating is on...

Page 12: ...C Certification Limited Warranty This unit has a 3 years warranty If at any time during this period the unit be comes defective it must be returned to its place of purchase with the invoice copy or simply contact our customer service department with a copy of the invoice in hand In order for the warran ty to be valid the unit must have been installed and used according to instruc tions If the inst...