background image

INS-TSSHC-3DNPSB-16.7A-1209

7

Night mode timer adjustment procedure

1. If necessary, adjust the Day/Night mode set 

points at the desired temperatures. If need­
ed, switch from one mode to the other by si­
multaneously pressing down the two buttons 
and releasing them immediately.

2. From the Night mode, simultaneously press 

down the two buttons for more than 3 sec­
onds  until  the  icon  SET  starts  to  blink,  in­
dicating  that  the  adjustment  of  the  Night 
mode timer is effective. The figures displayed 
above the word “AMBIENT” indicate the cur­
rent adjustment of the timer.

3. If needed, adjust the timer by pressing down 

the right button to increase the value, or the 
left  button  to  decrease  it.  The  adjustment 
range is from 1 hour to 999 hours. To quickly 
scroll  through  timer  values,  press  and  hold 
down the button.

4. When  the  adjustment  is  completed,  release 

the buttons and wait for 5 seconds to exit the 
adjustment function.

NB :

 The Night mode timer will be auto matically 

reinitialized to the latest re corded value when 
switching  from  the  Day  mode  to  the  Night 
mode. It is not necessary to readjust the timer 
every time you switch to the Night mode. The 
timer  is  also  reinitialized  when  this  value  is 
adjusted.

Once  the  timer  has  completed  its  cycle  and 

when the thermostat is in the Day mode, you 

must manually return to the Night mode. If you 

want to automatically return to the Night mode, 

the Automatic mode must be selected

Automatic mode

The  Automatic  mode,  which  is  associated  to 

the  Night  mode  timer,  allows  alternating  be-

tween  the  Day/Night  modes  and  the  two  cor-

responding  set  points  over  a  24-hour  period. 

Once activated, this mode allows an automat-

ic return to the Night mode after 24 hours. The 

Automatic mode allows you to define two peri-

ods in a single day with different set points.
For example, if the Automatic mode is activated 

and the Night mode timer is set at 8 hours, the 

thermostat will be operating in the Night mode 

for 8 hours at the night temperature set point. 

Then, it will return to the Day mode for 16 hours 

operating at the day temperature set point. At 

the end of the 24-hour cycle, the thermostat will 

return to the Night mode, and the cycle will start 

again.
The 24-hour cycle starts with the Night mode as 

soon as the Automatic mode is activated. The 

Automatic  mode  activation  should  be  made 

when you want to return to the Night mode. The 

normal course of a cycle in the Au tomatic mode 

is as follows :

1­ Night mode : activated for the duration of the 

Night mode timer cycle. It returns to the Day 
mode when the timer cycle is completed.

2­ Day mode : activated for the remaining time 

of the 24­hour cycle. It returns to the Night 
mode at the end of the 24­hour cycle.

Summary of Contents for TSSHC-3DNPSB-16.7A

Page 1: ...INS TSSHC 3DNPSB 16 7A 1209 User s guide For further information or to consult this guide on line please visit our Web site TSSHC 3DNPSB 16 7A Electronic thermostat www sshcinc com ...

Page 2: ...2 mounting screws and two 2 solderless connectors suitable for copper wires Before installing and operating this product the owner and or installer must read under stand and follow these instructions and keep them handy for future reference If these in structions are not followed the warranty will be considered null and void and the manu facturer deems no further responsibility for this product Mo...

Page 3: ...tat in a location where temperature measurements could be altered For example close to a window on an external wall or close to a door leading outside exposed directly to the light or heat of the Sun a lamp a fireplace or any other heat source close or in front of an air outlet close to concealed ducts or a chimney and in a location with poor air flow e g behind a door or with frequent air draft con...

Page 4: ...of the thermostat fron the mounting base by tilting it upward 5 Align and secure the mounting base to the connection box using the two screws sup plied 6 Reinstall the front part of the thermostat on the mounting base and tighten the screw at the bottom of the unit 7 Turn on the power 8 Set the thermostat to the desired setting see the following section Important you must activate the Fan mode whe...

Page 5: ...A 1209 5 3 Operation Ambient temperature Timer Modes Frost free Day Night Fan Automatic Heating power used indicator Temperature set point Button to decrease set point timer Button to increase set point timer Set point lock ...

Page 6: ...rom one mode to the other the system will automatically use the tempera ture set point corresponding to the Day Night mode selected The standard factory set point adjust ment is 68 F 20 C for the Day mode and 60 F 16 C for the Night mode The current Day Night mode selection is indi cated on the display by the Sun or Moon icon In order to manually switch from one mode to the oth er simulta neously ...

Page 7: ... and when the thermostat is in the Day mode you must manually return to the Night mode If you want to automatically return to the Night mode the Automatic mode must be selected Automatic mode The Automatic mode which is associated to the Night mode timer allows alternating be tween the Day Night modes and the two cor responding set points over a 24 hour period Once activated this mode allows an au...

Page 8: ...s and hold down the button NOTE If you set the timer to any value exceeding 23 hours it will be impossible to activate the Automatic mode and if it was activated the Automatic mode will be deactivated 3 Activate the Automatic mode by simultane ously pressing down the two buttons for at least 3 seconds The Automatic mode icon will appear If the Automatic mode was al ready activated the same procedu...

Page 9: ...heit or Celsius symbol will be displayed 3 When the adjustment is completed release the buttons and wait for 5 seconds to exit the adjustment function Fan mode When the thermostat is used to control a heat ing system equipped with a fan the Fan mode MUST be activated This mode prevents the system from continuously starting and stoping which could cause fan failure The Fan mode is by default deacti...

Page 10: ... ously press down the and buttons for more than 10 seconds until the Lock icon disap pears 6 Release the buttons The thermostat is now unlocked NOTE If the thermostat isn t unlocked within 5 minutes after the restoration of the power sup ply the Lock icon will stop to blink and it will be impossible to unlock the thermostat unless cut ting off the power supply again Heating power indicator The lev...

Page 11: ...ircuit breaker and intervening switches performance 5 The display turns off a few minutes and then turns on again The thermal protection of the heating unit has deactivated the unit due to overheating Check if the heating unit is in good condition of operation and that clearance around the appliance is according to the manufacturer s specifications 6 The display has low contrast when heating is on...

Page 12: ...C Certification Limited Warranty This unit has a 3 years warranty If at any time during this period the unit be comes defective it must be returned to its place of purchase with the invoice copy or simply contact our customer service department with a copy of the invoice in hand In order for the warran ty to be valid the unit must have been installed and used according to instruc tions If the inst...