Reset EE Normal
>No<
Factory Reset
d-3-4) Reset Load
User can reset the specific load’s energy if the inverter is installed with a
smart plug.
d-3-5) Factory Reset
User can reset the inverter manager parameter records here.
d-3-6) Config guide
This interface will trigger the initial setting guide re-play again.
>Start
Config guide
User-define
Work Mode
Relay Control
New Password
(d-4)
(d-4-1)
(d-4-2)
(d-4-3)
d-4-1) Work mode
There are 4 work modes for choice.
Setting
Setting
58
59
The Battery will charging forcibly in the setting time, and it can
choose whether charge from the grid or not. The battery stop
discharging to keep higher capacity when the grid is on. Only
when the gird is off and the power generated is not enough,
battery will start to discharge to keep the emergency load
working normally.
This work mode applies to the area where suffering from
blackout regularly.
The priority of inverter output power is:
supplying the load feeding to the grid charging the
battery.
This work mode applies to the area with high feed-in tariff.
Self Use
(default)
Force Time Use
Back Up Mode
Feed in Priority
The
external generator
generated power will be used to supply
the local loads firstly, then to charge the battery. The redundant
power will export to the public grid.
When there is no
external generator
supplied, battery will
discharge for local loads firstly, and grid will supply power when
the battery capacity is not enough.
In this work mode the charging and discharging time can be set
flexibly, and it also allows to select whether charge from the grid
or not.
Parameter
Comment
>Mode Select
Force time use
Work Mode
> Charge
Start time 1
08:00
Work Mode
>Charger period 1
From Grid
Enable
Work Mode
For “Force Time Use” mode, there are 2 parameters that needs to be set.
Reset Load1
>No<
Reset Load Consume
d-3-3) Reset Meter Energy
User can reset the meter energy record here.
Reset
>No<
Reset Met Energy