8.3 LCD Operation
●
Status
The status function contains five items of the inverter(grid, charger, eps and
Load).
Press up and down to select and press “OK” to confirm the selection, press “ESC”
to return to Menu.
a) Grid
This status shows the current grid condition such as voltage, current, output
power, the local consumed power and frequency.
Pout measures the output of inverter;
Pgrid measures power export to or import from grid.
Positive value means the energy feeds into grid, negative value means the
energy used from the grid.
LCD Digital Display
The main interface is the default interface, the inverter will automatically jump to
this interface when the system started up successfully or not operated for a
period of time.
The information of the interface is as below. “Power” means the instant output
power; “Today” means the power generated within the day. “Battery” means the
left capacity of battery energy.
Power
0W
Today 0.0KWh
Battery %
Normal
Status
History
Settings
Menu
Menu interface
The menu interface is a transfer interface for user to get into another interface
to change the setting or getting the information.
-User can get into this interface by pressing “OK” button when LCD displays the
main interface.
-User can select interface by moving the cursor with function button
,
and press
“OK” to confirm.
Menu
Status
History
Setting
System Switch
About
S
ta
tu
s
Grid
Load
EPS
Charger
Ø
Status
Grid
Charge
EPS
Status
Ua
0.0V
Ia
0.0A
PaOut
0W
Grid
44
45
Setting
Setting
b) Charger
This status shows the charger situation of the system. Include the battery
voltage, charge or discharge current. Charge or discharge power, battery
capacity, battery temperature, BMS status, charge and discharge limit. “+”
means in charging; “-” means in discharging.
U
400.0V
I
-1.0A
P
-400W
Charger