X3-Retro Fit 

User Manual

8.0kW - 10.0kW

Copyright Declaration

The copyright of this manual belongs to Solax Power Network Technology(Zhe jiang) Co,. Ltd. 
(SolaX Power Co.,Ltd.). Any corporation or individual should not plagiarize, partitially or fully 
copy (including software,etc.), and no reproduction or distribution of it in any form or by any 
means. All rights reserved. SolaX Power Network Technology (Zhe jiang) Co.,Ltd. (SolaX Power 
Co.,Ltd.). reserves the right of final interpretation.

614.00259.00

Solax Power Network Technology(Zhe jiang) Co,. Ltd.
(Solax Power Co,. Ltd)

Summary of Contents for X3-Retro Fit

Page 1: ...poration or individual should not plagiarize partitially or fully copy including software etc and no reproduction or distribution of it in any form or by any means All rights reserved SolaX Power Netw...

Page 2: ...of Inverter 4 Technical Data 4 5 General Data 4 4 EPS output apply to version E only 4 3 Efficiency Safety and Protection 4 2 Internal Charger 4 1 AC output input 5 3 Mounting 5 1 Check for Physical D...

Page 3: ...ntents Note Note provides tips that are valuable for the optimal operation of our product Warning Warning indicates a hazardous situation which if not avoided could result in death or serious injury 0...

Page 4: ...ay from humid or corrosive substance Authorized service personnel must use insulated tools when installing or working with this equipment The unit contains capacitors that remain charged to a potentia...

Page 5: ...side of this product For United Kingdom The installation that connects the equipment to the supply terminals shall comply with the requirements of BS 7671 Electrical installation of PV system shall co...

Page 6: ...stalling operating and servicing the unit If ignored physical injury or death may follow or damage may occur to the unit Read this instructions before you work on the unit If you are unable to underst...

Page 7: ...rter will shutdown with an overload fault warning Please confirm with the mains grid operator whether there is any special regulations for grid connection Digram A applies to the wiring rules that req...

Page 8: ...The redundant power will export to the public grid The charging and discharging time can be set flexibly In the case of the external generator the power generated will be used to supply the local loa...

Page 9: ...8000 8000 11 6 12 8 X3 Fit 8 0E X3 Fit 8 0C X3 Fit 10 0E X3 Fit 10 0C 8000 8000 11 6 12 8 10000 10000 14 5 16 0 10000 10000 14 5 16 0 400V 230VAC 380V 220VAC 50 60 7000 10 1 11 2 7000 10 1 11 2 7000 1...

Page 10: ...777 567 423 47 47 47 47 0 95 non condensing III Electric supply side II Battery side Nautral Transformerless Ethernet Meter WiFi optional RF optional DRM USB ISO alarm Backlight 20 4 character Standa...

Page 11: ...Not near the television antenna or antenna cable Not higher than altitude of about 2000m above sea level Not in environment of precipitation or humidity 95 Under good ventilation condition The ambien...

Page 12: ...sion tubes in the holes and tighten them Then install the wall bracket with the expansion screws Installation tools crimping pliers for binding post and RJ 45 screwdriver manual wrench and Step 1 Step...

Page 13: ...about 60mm of conductor material sectional area 3 3 Remove 12mm of insulation from the end of wire 3 4 Insert stripped wires into AC terminal and insure all conductor strands are captured in the AC t...

Page 14: ...d the operation guide above espescially for the wiring of neutral line grounding and RCD please contact us before any operation Electrical Connection Electrical Connection 24 25 EPS wiring diagram The...

Page 15: ...ppeared adjust the load power to make sure it is within the EPS output power range then turn the inverter back on For the nonlinear load please make sure the inrush power should be within the EPS outp...

Page 16: ...to see the fine wire strands in the chamber Step1 Choose the 9 AWG wire and strip the cable to 15mm Communication interface bewteen inverter and battery is CAN with a RJ45 connector BMS PIN Definition...

Page 17: ...n addtionally earth the inverter to the enclosure of a second earthing or equipotential bonding if it is required by local safety This prevents electric shock if the original protective conductor fail...

Page 18: ...ill shutdown with a Meter fault alert The meter communication only works when meter is compatible with the inverter Meter connection diagram Communication interface bewteen inverter and meter is RS485...

Page 19: ...le can still be connected when using LAN connection Could Router data cable 6 7 DRM Connection DRM is provided to support several demand response modes by emitting control signals as below DRM Connect...

Page 20: ...of the inverter Step2 Build the connection between the inverter and router 6 9 RF Connection optional X3 Retro fit inverter provides a RF radio frequency interface which control the switch time of a...

Page 21: ...s connected well Make sure all the AC wirings are completed Ensure the inverter fixed well on the wall Electrical Connection Electrical Connection 38 39 SolaX meter Battery DPDT E BAR Main switch RCD...

Page 22: ...tory is in accordance with above form strictly Do not modify the program file name or it may cause the inverter not work anymore Step2 Step3 Warning If the upgrading is broken off during operation ple...

Page 23: ...ownside or decrease value ESC button Return from current interface or function OK button Confirm the selection Up button Move cursor to upside or increase value LCD Screen Display the information of t...

Page 24: ...the instant output power Today means the power generated within the day Battery means the left capacity of battery energy Power 0W Today 0 0KWh Battery Normal Status History Settings Menu Menu interf...

Page 25: ...d Consume History The history function contains six items of the information inverter yield EPS yield load consume meter yield system run time and error logs Press up and down to select and press OK t...

Page 26: ...ory Reset Config Guide Work Mode Relay Control New Password Reset Errorlog Setting This function is used for setting of the inverter time connection battery grid and so on Enduser can set Date Time La...

Page 27: ...tries and grid tied stanndards There are 8 standards to select May change without notice Item 7 1 2 3 4 5 6 8 Country VDE 0126 ARN 4105 German AS 4777 Australia G83 2 UK EN 50438_NL Netherland CEI 0 2...

Page 28: ...Grid The enduser do not need to set the grid parameters All default value has set on factory according to safety rules If need to reset any changes should according to the requirement of local grid Pa...

Page 29: ...rid is balanced Select Disable means the three phase output power from inverter is balanced and it is the default value Function Control Disable Phase Power Balance d 1 7 Grid Service Grid Service can...

Page 30: ...it means EPS output is over loads Frequency here can be set 50Hz or 60Hz please based on correlative loads Mute No Frequency 50Hz EPS system Reset Reset Inv Energy Reset Meter Energy Reset Load Facto...

Page 31: ...from blackout regularly The priority of inverter output power is supplying the load feeding to the grid charging the battery This work mode applies to the area with high feed in tariff Self Use defau...

Page 32: ...new password here System Switch System Switch can be selected from ON or OFF ON means the inverter is on working condition and it is inverter default status OFF means the inverter stop delivering all...

Page 33: ...ange for the last 10 Minutes The system will back to normal if the grid is back Or seek for help from us DCV OCP Fault DCV EPS over voltage protection Fault Or seek for help from us Wait for a while t...

Page 34: ...ect grid and battery reconnect them Or seek help from us if can not go back to normal state BMS_External_Err Battery Fault extarnal fault Please contact battery suppiler BMS_Internal_Err Battery Fault...

Page 35: ...ed at least every 12 mouths please contact manufacturer to arrange qualified person who has adequate training kownledge and practical experience to perform these tests Please kindly noted this action...