3. Introduction
10
11
Introduction
Introduction
3.1 Basic features
X1-
Series is a high-quality inverter which can store energy into battery.
Retro Fit
The inverter can be used to optimize self consumption, store in the battery for
future use or feed-in to public grid. Work mode depends on the battery and user’s
preference. It can provide power for emergency use during the grid lost by using
the energy from battery.
System Diagram
►
X1-Retro Fit Series is designed with two EPS versions for customer to choose
based on the local rules.
E Version
applies to the wiring rules
requires the Live line and Neutral line of
that
E
must
with the Live line and Neutral line of grid
PS
be disconnected
. (applies to
most countires)
SolaX meter
+
-
Battery
DPDT
E
-
BAR
Main switch
RCD
RCD
PE
EPS
Load
Inverter
I Version
applies to the wiring rules that requires Neutral line of alternative supply
must NOT be isolated or switched (applies to wiring rules AS/NZS_3000:2012 for
Australia and New Zealand).
SolaX meter
+
-
Battery
E
-
BAR
Main switch
RCD
RCD
EPS
Loads
Inverter
Loads
Note!
Please control the home loads, and make sure it’s within the “EPS
output rating” under EPS mode, otherwise the inverter will shutdown
with an “overlaod fault” warning.
Please confirm with the mains grid operator whether there is any
special regulations for grid connection.
•
•