background image

Copyright Declaration

X1-Retro Fit

User Manual

3.7kw - 5.0kw

614.00204.04

Solax Power Network Technology(Zhe jiang) Co,. Ltd.

The copyright of this manual belongs to Solax Power Network Technology(Zhe jiang) Co,. 
Ltd.. Any corporation or individual should not plagiarize, partitially or fully copy (including 
software,etc.), and no reproduction or distribution of it in any form or by any means. All rights 
reserved. SolaX Power Network Technology (Zhe jiang) Co.,Ltd. (SolaX Power Co.,Ltd.). reserves 

Summary of Contents for X1-Retro Fit

Page 1: ...this manual belongs to Solax Power Network Technology Zhe jiang Co Ltd Any corporation or individual should not plagiarize partitially or fully copy including software etc and no reproduction or distr...

Page 2: ...apply to version E I C 4 4 EPS output apply to version E I 4 3 Efficiency Safety and Protection apply to version E I C 4 2 Internal Charger apply to version E I C 4 1 AC output input apply to version...

Page 3: ...s Danger Danger indicates a hazardous situation which if not avoided will result in death or serious injury Warning Warning indicates a hazardous situation which if not avoided could result in death o...

Page 4: ...installing or working with this equipment The unit contains capacitors that remain charged to a potentially lethal voltage after the MAINS battery has been disconnected and Hazardous voltage will pre...

Page 5: ...ould be observed during battery replacement 1 Do not wear watches rings or similar metallic items 2 Use insulated tools 3 Put on rubber shoes and gloves 4 Do not place metallic tools and similar metal...

Page 6: ...n installing operating and servicing the unit If ignored physical injury or death may follow or damage may occur to the unit Read this instructions before you work on the unit If you are unable to und...

Page 7: ...rules requires the Live line and Neutral line of that E must with the Live line and Neutral line of grid PS be disconnected applies to most countires SolaX meter Battery DPDT E BAR Main switch RCD RC...

Page 8: ...d battery grid when discharg ing This mode applies the area that has electricity price between peak and valley User can use off peak electricity to charge the battery In the case of the external gener...

Page 9: ...installation WARNING 3680 4000 bypass 4600 5000 bypass 4999 5000 bypass X1 Fit 3 7I X1 Fit 3 7C X1 Fit 4 6E X1 Fit 4 6I X1 Fit 4 6C X1 Fit 5 0E X1 Fit 5 0I X1 Fit 5 0C 4 1 AC output input apply to ve...

Page 10: ...e Storage Operation relative humidity Altitude m Ingress Protection Protective Class Over Voltage Category Cooling Noise emission typical Inverter Topology Communication interface LCD display Installa...

Page 11: ...t higher than altitude of about 2000m above sea level Not in environment of precipitation or humidity 95 Under good ventilation condition The ambient temperature in the range of 20 to 60 The slope of...

Page 12: ...enough at least 60mm to support the inverter 1 3 Install the expansion tubes in the holes and tighten them Then install the wall bracket with the expansion screws Installation tools crimping pliers fo...

Page 13: ...nd insure all conductor strands are captured in the AC terminal 3 5 Compress the AC terminal head by using a crimping pliers and screw down screw cap tightly Step4 Insert AC cable into Grid port throu...

Page 14: ...ggered either automatically or manually according to user s preference If user wants to use this function manually it will need to be installed an external switch Please refer to specific wiring diagr...

Page 15: ...range then turn the inverter back on For the nonlinear load please make sure the inrush power should be within the EPS output power range Configuration current less than the maximum dc input current g...

Page 16: ...munication connection Communication interface bewteen inverter and battery is RS485 or CAN with a RJ45 connector BMS PIN Definition DC plug housing DC socket housing screw connection screw connection...

Page 17: ...nnector into BMS port inside of inverter and screw it tightly Then insert other side of communication cable into RS485 or Can port on the battery Battery BMS module Pylontech RS485 port Triple Power C...

Page 18: ...h a Meter fault alert unless the meter function is shut down though CD operation L The smart meter must be authorized by Solax any third party or non authorized meter may not match with the inverter S...

Page 19: ...nto COM port at the bottom of inverter and screw it tightly Then insert other side of the network cable into PC or other device Step1 Prepare a standard network cable without sheath and find the cable...

Page 20: ...ection Steps Step3 for the external network cable operation please refer to 485 connection steps Step1 Open the lid cover then it can be seen that a network cable has been inserted in the 485 RJ45 por...

Page 21: ...Increase power generation subject to constraints from other active DRMs Do not consume power Do not consume at more than 50 of rated power DRM1 DRM2 DRM3 DRM4 Note Only PIN6 DRM0 and PIN1 DRM1 5 are a...

Page 22: ...lier if needed Pocket Wifi Connection Diagram WiFi Connection Steps Step3 Create a user account online Please check the Pocket WiFi user manual for more details Step1 Plug Pocket Wifi into WiFi port a...

Page 23: ...test function in accordance with CEI 0 21 During the self test the inverter will consecutively check the protection reaction times and values for overvoltage undervoltage overfrequency and underfrequ...

Page 24: ...ot modify the program file name or it may cause the inverter not work anymore Update ARM DSP Update DSP Updating 25 Step2 U disk Step3 Warning If the upgrading is broken off during operation please en...

Page 25: ...em Switch About Date Time Advanced Language Ethernet need password On grid New password Battery Reset Charger EPS system Reset Inv Energy Reset Meter Energy Reset Load Reset Mgr EE Config Guide Reset...

Page 26: ...main interface User can select interface by moving the cursor with function button and press OK to confirm Menu Status History Setting System Switch About Status U 000 0V I 00 0A P 00 0W Grid 48 49 S...

Page 27: ...2 EPS Yeild The EPS Yield function contains EPS yield for today and total Today 0 0KWH EPS Yield OutputGridToday 0 8KWH Inverter Yield History Inverter Yield Error Logs Meter Yield EPS Yield Inv Warni...

Page 28: ...te time English Deutsch Language 3 3 Ethernet There are two modes to obtain IP address static and DHCP User can set the information about ethernet such as IP address subnet mask number and default gat...

Page 29: ...at needs to be set Charger start time1 Charger end time1 Charger start time2 Charger end time2 Parameter 3 6 Advanced All the advance setting can be set here such as battery grid EPS and so on Advance...

Page 30: ...50438_NL only Reactive power control Reactive standard curve cos f P For VDE ARN 4105 curve cos f P should refer to curve A default value of setting is as shown in curve A For E 8001 curve cos f P sho...

Page 31: ...output power allowed If the user do not want feed any power into grid please set it to 0 User value Export Control 4000W Func Select Enable Remote Control connecting 3 6 1 5 Remote Control Remote cont...

Page 32: ...Click test report to obtian all items test result ALL Test Test report Uvp 27 S1 test Ft 51 50Hz Tt 1000ms Fs 0 00Hz To 998ms F0 0 00Hz pass Ofp2 81 S2 result Vt 264 5V Tt 300ms Vs 0 0V To 200ms V0 0...

Page 33: ...is sufficient start the Battery Awaken function the inverter will exit the Battery Awaken automatically Battery Awaken Charger NO 3 6 2 2 EPS system For I E Version only X1 Retro fit inverter with I E...

Page 34: ...er need to work with Energy meter to achieve hybrid functions In hybrid system if there is other power device in the system which is also wanted to be monitored It can install two meters to monitor bo...

Page 35: ...nd provides you with troubleshooting tips to identify and solve most problems that could occur with the X1 Retro Fit inverters This section will help you narrow down the source of any problems you may...

Page 36: ...bnormal Check if two MPPTs connect in a parallel mode Please connect the two MPPTs indepedently Or seek help from us if can not go back to normal state Inter Com Fault Internal Communication Fault Or...

Page 37: ...e check time to time 2 Check that if the indicators of the inverter are in normal state check if the keys of the inverter are in normal state check if the display of the inverter is normal This check...

Page 38: ...rements Suitable for loads more than 30 kg With handle Can be fully closed Store the inverter in a dry environment where ambient temperature keep always between 20 C 60 C Take care of the inverter dur...

Reviews: