3.2
Basic Features
3.2.1
Features
The T-BAT SYS-HV is one of the advanced energy storage systems on the market
today, incorporating state-of-the-art technology, high reliability, and convenient
control features shown as below:
Ÿ
90% DOD
Ÿ
99% Faradic charge efficiency
Ÿ
95% Battery roundtrip efficiency
Ÿ
Cycle life > 6000 times
Ÿ
Secondary Protection by hardware
Ÿ
IP55 protection level
Ÿ
Safety & Reliability
Ÿ
Small occupied area
Ÿ
Floor or wall mounting
3.2.2
Certifications
3. Product Introduction
3. Product Introduction
10
11
T-BAT system safety
Battery cell safety
UN number
Hazardous materials classi cation
UN transportation testing requirements
International protection marking
CE, FCC, RCM, TUV (IEC 62619), UL 1973
UL 1642
UN 3480
Class 9
UN 38.3
IP 55
3.3
Specifications
3.3.1
T-BAT SYS-HV Configuration List
3.3.2
Performance
Model
BMS
Battery Module Energy(kWh) Voltage (V)
No.
1
2
3
4
5
6
7
8
T-BAT H4.5
T-BAT H9.0
T-BAT H13.5
T-BAT H18.0
T-BAT H6.3
T-BAT H12.6
T-BAT H18.9
T-BAT H25.2
MC0500x1
MC0500x1
MC0500x1
MC0500x1
MC0500x1
MC0500x1
MC0500x1
MC0500x1
HV10045X1
HV10045X2
HV10045X3
HV10045X4
HV10063X1
HV10063X2
HV10063X3
HV10063X4
4.5
9
13.5
18
6.3
12.6
18.9
25.2
85-118
170-236
255-354
340-472
85-118
170-236
255-354
340-472
MC0500
HV10045
HV10063
Nominal Voltage(Vdc)
Operating Voltage(Vdc):
Nominal Capacity(Ah):
Max. charge/discharge Current(A) :
Recommend Charge/Discharge Current (A):
Standard Power(kW)
Maximum Power(kW)
/
70-500
/
30
25
/
/
100.8
85-118
45
30
25
2.5
3
100.8
85-118
63
30
25
2.5
3
Faradic Charge Efficiency
(25℃/77℉)
Battery Roundtrip Efficiency
(C/3,25℃/77℉)
Expected Lifetime
(25℃/77℉)
Cycle life
(
100% DOD
,25℃/77℉)
Available Operating Temperature
Optimal Operating Temperature
Storage Temperature
Ingress Protection
99%
95%
5 years
6000 cycles
0--40
℃
15
℃
--30
℃
-20
℃
--60
℃
IP55