background image

 

THIS POWER VENT KIT IS ONLY FOR USE WITH THE FOLLOWING SÓLAS MODELS: 

SL-16N, SL-16P, SL-26N, SL-26P, ST-46N, ST-46P, FS-16N-RV, FS-16P-RV, FS-16N-TV, FS-16P-TV, BI-38N-C, BI-38P-C,  

BI-38N-T, BI-38P-T, BI-48-SSL, BI-48-SSR, BI-48-ST, BI-60-SSL, BI-60-SSR, BI-60-ST, BI-72-SSL, BI-72-SSR, BI-72-ST 

SELF

SELF

SELF

SELF----CALIBRATING

CALIBRATING

CALIBRATING

CALIBRATING    

POWER

POWER

POWER

POWER

    

VENT

VENT

VENT

VENT

    

CONTROL

CONTROL

CONTROL

CONTROL    

AND

AND

AND

AND

    

TERMINATION

TERMINATION

TERMINATION

TERMINATION

    

KIT

KIT

KIT

KIT    

    

Ce manual est disponsible en Francais sur demande. 

SCPV-900C SHOWN 

SÓLAS STRONGLY SUGGESTS THAT YOU READ THIS 
MANUAL THOROUGHLY BEFORE BEGINNING THE 
INSTALLATION OF THE SÓLAS POWER VENT KIT.  THIS 
SPECIFIC PRODUCT HAS ITS OWN UNIQUE SET-UP AND 
INSTALLATION REQUIREMENTS THAT MUST BE 
FOLLOWED EXACTLY.  PLAN YOUR INSTALLATION IN 
ADVANCE BY CAREFULLY RE-VIEWING ALL THE 
INFORMATION CONTAINED IN THIS MANUAL. 

 

WARNING: ALL INSTALLATION, SERVICING, AND 
TROUBLESHOOTING MUST BE PERFORMED BY A 
QUALIFIED GAS TECHNICIAN. 

Summary of Contents for SCPV-12218-100

Page 1: ...CONTROL CONTROL AND AND AND AND TERMINATION TERMINATION TERMINATION TERMINATION KIT KIT KIT KIT Ce manual est disponsible en Francais sur demande SCPV 900C SHOWN S LAS STRONGLY SUGGESTS THAT YOU READ...

Page 2: ......

Page 3: ...ibration and Operation 17 Troubleshooting 20 Replacement Parts List 22 Warranty Information 23 WARNING This installation manual covers the functional requirements for optimal performance of your firep...

Page 4: ...Powervent control kit SCPV 914GS Self Calibrating Power Vent Gas Solenoid required for all power vent installations Only gas solenoids certified for use by S LAS are to be used with the S LAS Self Ca...

Page 5: ...s termination requires the use of SCPV 946DVA Self Calibrating Power Vent Pressure Port Vent Adapter SCPV 459SM Self Calibrating Power Vent Surface Mount Termination for use with vent runs over 10 fee...

Page 6: ...0 SSL BI 60 SSR BI 60 ST BI 72 SSL BI 72 SSR BI 72 ST This kit uses either M G Duravent direct vent pipe Secure Vent direct vent pipe or Selkirk Direct temp vent pipe with a 4 inner pipe and a 6 5 8 o...

Page 7: ...6 FLUSH MOUNT TERMINATION SPECIFICATIONS SCPV 160FM Self Calibrating Flush Mount Power Vent Dimensions SCPV 160FM Self Calibrating Flush Mount Power Vent Cavity Dimensions NAILING FLANGE FLUE OUTLET...

Page 8: ...9SM Self Calibrating Surface Mount Power Vent Dimensions SCPV 459SM Self Calibrating Surface Mount Power Vent Cavity Dimensions These dimensions apply to SCPV 459SM and SCPV 459SM 10 see page 12 for S...

Page 9: ...rom the center line of the regulator I clearance to service regulator vent outlet 6 feet 1 8 m minimum J clearance to non mechanical air supply inlet to building or the combustion air inlet to any oth...

Page 10: ...minimum clearance to combustibles and electrical wiring of 1 5 38mm is required around the vent pipe at all times Failure to maintain this clearance may result in property damage injury or death NOTE...

Page 11: ...heathing is 14 50 368mm wide by 14 50 368mm tall as shown in the image right 2 The power vent termination is secured to the sidewall by the left right top and bottom nailing flanges shown on page 6 3...

Page 12: ...ening required in the framing and exterior sheathing is 14 50 368mm wide by 10 00 254mm tall as shown in the image right 2 The power vent termination is secured to the sidewall by the left and right n...

Page 13: ...nsional requirements for the site fabricated chase WARNING This installation manual covers the functional requirements for optimal performance of your fireplace with power vent installation consult wi...

Page 14: ...outlet is on the 12 9 328mm long side of the chase 2 Exterior dimensions of the site fabricated chase should be 18 9 480mm long by 455mm wide The exhaust outlet is on the 18 9 480mm long side of the c...

Page 15: ...e top edge of the Self Calibrating Power Vent Control The lower Termination Harness Plug is for the Termination Wire Harness which carries power to the power vent and restrictor position signals back...

Page 16: ...ent control SCPV 900C Only use the length of tubing that is necessary for your installation trim to length Tape all seams in the venting system using Aluminum Foil HVAC Tape For vent runs that are und...

Page 17: ...ace is enclosed within the wall WARNING All electrical shall be completed by a licensed Electrician and must conform with local building code Improper installation may result in property damage injury...

Page 18: ...N THE POWER VENT CONTROL THE CONTROL WILL BEGIN A 60 SECOND PURGE CYCLE DURING THIS PURGE CYCLE THE CALIBRATION SEQUENCE CANNOT BE INITIATED DURING THE PURGE CYCLE THE OPERATION STATUS LED WILL BE BLU...

Page 19: ...quence at any time in the product s life this is ok 3 Without any user intervention the calibration sequence is as follows The restrictor contained within the power vent termination will close Once th...

Page 20: ...PRESSED ON THE POWER VENT CONTROL THE CONTROL WILL BEGIN A 60 SECOND PURGE CYCLE DURING THIS PURGE CYCLE THE CALIBRATION SEQUENCE CANNOT BE INITIATED DURING THE PURGE CYCLE THE OPERATION STATUS LED WI...

Page 21: ...securely plugged into both the control and the termination Concern Calibration Status LED turns red when Calibration button is pressed Cause Pressure switch is closed while power vent is off Check 1...

Page 22: ...status LED turns red after the pilot lights but before the main burner ignites Cause Power vent control did not get signal pressure switch has closed Check 1 Is the pressure switch plugged in 2 Actuat...

Page 23: ...wer Vent Flush Mount Termination requires SCPV 946DVA 10 SCPV 459SM Self Calibrating Power Vent Surface Mount Termination for use with vent runs over 10 feet in length requires SCPV 946DVA 11 SCPV 459...

Page 24: ...and will nullify this warranty This warranty is void if a The unit has been operated in atmospheres contaminated by chlorine fluorine or other damaging chemicals b The unit is subject to submersion i...

Page 25: ...24 V1 5 5 20...

Reviews: