GAS CONVERSION
GAS FLOW ADJUSTMENT
It is required you adjust the gas valve when converting
the fireplace.
1. Locate and remove the pressure conversion brass plug
and set it for NG or LP accordingly. Reinstall and tighten.
2. Locate and loosen the two 1/4" - 20 nuts under gas
valve assembly in the front of the fireplace, using a
7/16" socket with 6" exension. To locate the second
one it is necessary to to swing the receiver module
up to the left.
3. The entire gas valve assembly is on flexible connectors
which allows you to lift it out of the fireplace as shown.
Be sure all wires and gas lines are free when pulling
gas valve assembly out of fireplace.
4. Confirm inlet pressure of gas (top pressure tap on
valve) is between 5.5" w.c. to 10.0" w.c. for natural
gas and 11" w.c. to 13" w.c. for propane. If pressure is
not within these parameters, correct any gas supply
pressure issue before continuing with conversion.
Close the pressure tap.
5. Install a pressure gauge on the outlet pressure tap
on the valve.
6. Light the fireplace using the remote control.
7. With the fireplace set on the highest flame level, set the
high manifold pressure by adjusting the small flat screw
set within the brass pressure conversion plug. Refer to
the chart below for high pressure settings which vary
per model fireplace.
8. With the fireplace set on the lowest flame level, set
the low manifold pressure by adjusting the 4mm allen
screw on the bottom side of the valve. Refer to the
chart below for low manifold pressure settings which
vary per model fireplace.
9. Ensure all pressure taps are closed and check all
connections/pressure taps for leaks.
(continued on next page)
MANIFOLD PRESSURE SPECIFICATIONS
MODEL
HIGH PRESSURE
LOW PRESSURE
ONE6 - LP
10.0” w.c. / 2.5kPa
3.1” w.c. / 0.77kPa