Solas-Nua FS-16N RV Installation & Operation Manual Download Page 30

30 

 

2.8. Configuration Menu  

 
To acess the configuration menu, 

press the OFF            button on the remote control for 40 seconds. During 

this time the screen may go blank, this is normal. After 40 seconds, the Configuration menu appears. This is a 
list of the settings that can be changed in the configuration menu: 
 

Pairing:  

This feature establishes communication between the remote and the fire-

place. Pairing will not be required unless communication is lost or, you have a new 
remote control. If pairing is required it must be done on channel A (go to the last 
option in the configuration menu by pressing     and select channel A).  
 
After that, go to pairing option again and press the select button (middle button) 
and when off is highlighted, press the change button (left button) off becomes on.  
 
Once the pairing is on, you have 20 seconds to push (press and release) the button 
S1 (yellow) in the control unit.  
 
Once this operation is done, you hear a beep in the control unit and on the control 
unit will appear:  
 
 
To return to the home screen press the back button until you get to main screen.  
 

PS: If pairing has been attempted previously and has not been achieved, try the follow-
ing:  
- Press and hold the OFF           button  for 40 seconds.  
- Set the channel on channel A.  
- Select On in the pairing setting.  
- Unplug the batteries from the control unit (wait 10 seconds) and plug the  
batteries back in.  
- Once the valve has finished moving, repeatedly push (press and release) the S1 but-
ton (yellow button on the control unit), until you hear the beep that confirms that pair-
ing has taken place

.  

 
 

Thermostat: 

This option enables or disables the auto thermostat mode. To enable it, select Yes. To disable it 

select No. 

 

 

Gap Temp: 

this option refers to the tolerance between the desired temperature and the current one. If the dif-

ference is greater than this gap temperature setting, the flame level increases. For example: the desired tem-
perature is set at 20°C and the current temperature is 18°C:

 

• If the Gap Temp is 0.5°C: Flame level will go to maximum level because the difference is 2°C.  
• If the Gap Temp is 1°C: Flame level will go to medium level as difference of 2°C is two times the gap set-
ting.  

If the Gap Temp is 2°C: Flame level will go to minimum level as the difference of 2°C is equal to the gap 

setting.  

 

COPRECI   R-emotion  CONTROL SYSTEM 

Summary of Contents for FS-16N RV

Page 1: ...lowed exactly a fire or explosion may result causing property dam age personal injury or loss of life WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch d...

Page 2: ...NSTALLATION RECORD FORM 38 WARRANTY INFORMATION 39 TABLE OF CONTENTS WE STRONGLY SUGGEST THAT YOU READ THIS MANUAL THOROUGHLY BEFORE BE GININNG THE INSTALLATION OF THE SOLAS NUA FREESTANDING DIRECT VE...

Page 3: ...of the appliance A commercially available hearth pad meets this requirement The appliance area must be kept clear and free from combustible materials gasoline and other flammable vapors and liquids Th...

Page 4: ...r use with the fuel type indicated on the rating plate This appliance has been certified by OMNI Test Laboratories Inc to ANSI Z21 88a 2007 CSA 2 33a 2007 Vented Gas Fireplace Heaters and CAN CGA 2 17...

Page 5: ...ruction are listed below In addition access to the gas supply must be considered The location of the stove will also affect the venting requirements and you must be certain the location will allow com...

Page 6: ...d on each additional level of the dwelling building or structure served by the appliance It shall be the responsibility of the property owner to secure the services of qualified licensed professionals...

Page 7: ...installation will include at least one 90 elbow Up to three additional 90 elbows or equivalent 45 elbows may also be used The total venting may not exceed 20 feet of vertical rise and or 10 feet hori...

Page 8: ...r stove will not be venting directly though an outside wall to a horizontal termination or if more than 30 of horizontal vent run is required some vertical vent rise will be required for the fireplace...

Page 9: ...B NU B NU B NU 11 10 B NU B NU B NU B NU B NU B NU B NU B NU B NU B NU B NU B NU 10 9 B NU B NU B NU B NU B NU B NU B NU B NU B NU B NU B NU 9 8 B NU B NU B NU B NU B NU B NU B NU B NU B NU B NU B NU...

Page 10: ...B 3 B 3 B 3 B 3 B 3 B 3 B 3 B 3 B 3 B 3 B 3 10 9 B 3 B 3 B 3 B 3 B 3 B 3 B 3 B 3 B 3 B 3 B 3 9 8 B 4 B 4 B 4 B 4 B 4 B 4 B 4 B 4 B 4 B 4 B 4 8 7 B 4 B 4 B 4 B 4 B 4 B 4 B 4 B 4 B 4 B 4 B 4 7 6 B 4 B 4...

Page 11: ...A VERTI CAL RISE AND HORIZONTAL RUN SNORKEL CAPS HAVE BUILT IN VERTICAL RISE THAT MUST BE COUNTED D TOTAL NUMBER OF 90 ELBOWS _______ NOTE SNORKELS COUNT AS 2 90 ELBOWS E TOTAL NUMBER OF 45 ELBOWS __...

Page 12: ...zontal Run Exhaust Restrictor Required B Air Restrictor Tabs Open 3 A Fuel LP Gas B Total Vertical Vent Rise 2 feet C Total Horizontal Vent Run Actual 10 feet D 90 Elbows Needed 2 E 45 Elbows Needed 0...

Page 13: ...13 VENT TERMINAL CLEARANCES Venting terminals shall not be recessed into a wall or siding...

Page 14: ...items 1 Installation and operation Manual 2 A C Adapter 3 Vent Restrictor Kit 4 Glass Media burner 5 Remote Control 6 Battery Pack 7 Levelling bolts 4 8 Blow Off Relief Door The stove has been bolted...

Page 15: ...page 7 to make that determination If your installation does require an air restrictor or exhaust restrictor or both these must be installed be fore you connect your vent system to the stove Again refe...

Page 16: ...ove body 6 Place the vent starter pipe gasket on the back of the stove aligning the holes in the gasket with the pilot holes on the rear of the fireplace 7 Align the inner pipe of the vent starter pip...

Page 17: ...lly clip one corner of the poly bag to form a pouring spout The opening should be large enough to allow the glass media to flow but not so large that you can t control the flow 3 You will notice that...

Page 18: ...f door enough to allow the rear line up tab to engage the rear retainer slot Refer to the sec ond illustration below 5 Rotate the front edge of each relief door so they line up over front retainers 6...

Page 19: ...Replace the battery pack on the bracket and secure with the hook and eye strap 6 Reconnect the battery connector to the Electronic Module Note An optional A C adapter is also supplied with the unit a...

Page 20: ...tom front of the fire box Take care to center the frame from left to right 3 Once the bottom edge is in place move your fingers out of the way and press the top of the frame against the firebox while...

Page 21: ...system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5kPa 6 The fireplace must be isolated from the gas supply piping system by closing the gas shut off valve dur...

Page 22: ...the pilot Do not try to light the pilot by hand 3 If using the Remote Handset push the button until you hear an audible signal to insure the appliance is off 4 Wait five 5 minutes to clear out any ga...

Page 23: ...burner has been in operation for a few minutes the flames should look like those in the illustration below Note The flame height will vary depending on the firing rate setting but flames should be eve...

Page 24: ...te that the system has accepted the order and the flame will light on the High setting To decrease the flame level press the DOWN button A beep and a flash of the LED indicate that the sys tem has acc...

Page 25: ...me C Signal strength D Selected working mode E Selected setting F Current flame status G Current fan status Not Applicable on this appliance H Current room temperature I Child lock status J Button lab...

Page 26: ...ible that the remote is locked in the OFF screen to unlock it just press the button below Unlock and then OK 2 3 Switching on Once the remote is unlocked press ON left button and OK middle button A be...

Page 27: ...27 COPRECI R emotion CONTROL SYSTEM...

Page 28: ...et in the configuration menu This specified the maximum permitted room temperature This temperature can never be set higher than 104 F 40 C It is recommended you set to 95 F 35 C Auto Thermostatic Mod...

Page 29: ...ppliance will heat until this temperature is reached Comfort Temp The comfort temperature is set as the desired temperature and the appliance will heat until this temperature is reached Finally to lau...

Page 30: ...ou get to main screen PS If pairing has been attempted previously and has not been achieved try the follow ing Press and hold the OFF button for 40 seconds Set the channel on channel A Select On in th...

Page 31: ...possible range of values is 77 104 F 25 40 C Suggested setting is 95 F 35 C Channel There are three different channels available A Band C These different channels make it possible to have more than o...

Page 32: ...32 TROUBLESHOOTING...

Page 33: ...e in the frame so it is very important to support both the glass and the frame when handling Place your thumbs on the outside of the glass frame and wrap your fingers around the frame and onto the gla...

Page 34: ...Burner and Firebox During the annual inspection and maintenance appointment the service person should clean the burner and firebox To gain access to the firebox and burner follow the instructions begi...

Page 35: ...Gas Connections Other __________________________ MAINTENANCE LOG Date of Service ____________________ Serviced By ______________________ Service Performed Inspect Venting Clean Burner Firebox Clean C...

Page 36: ...36...

Page 37: ...ls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing A B C D E F G H Caution Label all wires prior to disconnection when servicing the controls Wiring er...

Page 38: ...ow that describes the details of the installation Having this writ ten record of installation information available will greatly expedite trouble shooting should any problem arise with your stove The...

Page 39: ...39 4 Technology Drive Suite 5 West Lebanon NH 03784 Telephone 603 298 5169 Fax 603 298 9246 Sales hearthinnovations com...

Page 40: ...40 V1 01 2013 Manufactured by Progressive Manufacturing Inc 4 Technology Drive Suite 5 West Lebanon NH 03784 USA www hearthinnovations com...

Reviews: