SolarPower Pipe Layout Drawing 

 

 

1.

 

The  warranty  only  applies  where  the  SYSTEM  has  been  installed  and  commissioned  according  to 

SOLARPOWER installation instructions and by an authorised SOLAPOWER installer or licensed plumber.          

 

2.

 

Free  repair  or  replacement  is  provided  within  the  metropolitan  area  of  Australian  capital  cities  as  defined  by 

SOLARPOWER within 30km of the city centre or a branch, office or accredited service agent. In other areas 
defective parts or SYSTEMS must be returned to the point of sale before replacement can be considered under 
the  terms  of  the  warranty.    Freight  and  insurance  charges  for  the  transport  of  a  defective  and  replacement 
SYSTEM or parts are payable by the owner.   

 

3.

 

Where a failed component or SYSTEM is replaced under warranty, the balance of the original warranty period 

shall remain effective.  The replaced part or SYSTEM does not carry a new warranty. 

 
4.

 

The warranty only applies to the SYSTEM and does not cover any plumbing or electrical parts.  The electrical 

element, the circulator pump and pump controller have a 12-month replacement warranty. 

   

5.

 

Warranty  claims  must  include  all  details  listed  overleaf  and  should  be  made  to  the  point  of  sale  or  to  the 

company address listed below within one (1) month of the appearance of the defect.  

 

6.

 

This warranty does not cover the SYSTEM where it is found that the SYSTEM does not suffer a defect; where 

the  complaint  is  related  to  solid  matter  lodging  under  valve  seats;  where  there  is  a  failure  of  water  supplies, 
electrical supplies or the result of extreme water pressure or thermal input. 

 

7.

 

This warranty does not cover the SYSTEM where the SYSTEM is located in a position that does not comply 
with either the SolarPower installation instructions or the relevant statutory requirements and as a consequence 
there is a need for major dismantling or removal of doors, walls etc, or the use of special equipment to bring the 
SYSTEM to ground level. 

 

8.

 

This  Warranty  excludes  the  removal  of  scale  formation  in  the  waterways  where  the  SYSTEM  has  been 

connected to a harsh water supply. 

 

9.

 

Subject  to  any  statutory  provisions  to  the  contrary,  this  warranty  excludes  claims  for  damage  to  furniture, 

carpets, walls, foundations, or any other consequential loss either directly or indirectly due to leakage from the 
SYSTEM. 

 

10.

 

The  collector  glass  cover-plate  is  not  covered  by  this  Warranty.    Your  household  insurance  policy  should  be 

extended to include breakage of the collector cover-plate glass. 

 

11.

 

This warranty excludes damage resulting from acts of God, fire, lightning, flood, earthquake, landslide, storm, 

hail, frost, wind or other adverse weather conditions 

 

12.

 

The warranty excludes damage resulting from misuse, faulty installation or repairs carried out by persons other 

than a SOLARPOWER accredited service agent or technician. 

 

13.

 

Water  Quality,  must  meet  the  detailed  description  of  the  requirements  for  water  quality  as  listed  in  the 

installation manual. 

Summary of Contents for SP4002

Page 1: ... SP4002 Split System This manual uses the following conventions and symbols to highlight points of note throughout the manual Read this manual before you start to use this equipment SAFETY WARNING The manual contains important safety instructions WARNING Failure to follow the instructions in this manual can cause serious injury and or equipment failure GENERAL NOTICE ...

Page 2: ...List Item No Qty Description 1 1 SP4002 400L storage tank with pump attached 2 2 SP225 solar collector 3 2 2610mm L x 38mm W x 25mm H x 1 6mm T Upper mounting rail 3 units required for Cyclone areas 4 1 Accessory bag contains brackets screws and assorted plumbing fittings for full panel fit off 5 1 Installation Owner s Manual Please check to make sure all these components are included with the kit...

Page 3: ...rail as a guide mark and drill the roof material with a 5mm pilot hole This may not be needed for tin roofs as the screws supplied are self tapping 5 For tile roofs drill the tiles using a 12 14mm concrete drill bit paying careful attention for any cracking in the tiles Replace any cracked tiles with a new tile before continuing 6 Once the holes have been drilled place a fill the hole with silicon...

Page 4: ...alve needs to be commissioned and checked to ensure the valve top is opened and that when the pump operates the valve seals properly This can be done by listening to the valve to ensure air is not entering the pipe work Let the pump run for 3 5 minutes if air is still bubbling into the tank at this stage the valve is not sealing Place the Flow Control Disc into the return line tank connection to p...

Page 5: ...ion check the panels and associated plumbing for leaks while the pump is operating Leaks above the water line of the tank will suck air in rather than leak water out When checking for leaks if you can hear air bubbling in the tank after the pump has been running for a while more than 5mins it is likely that air is leaking in somewhere in the piping COLLECTOR INSTALLATION IN CYCLONE AREAS The Solar...

Page 6: ... and service in mind The panels should be located as close as possible to the storage tank CLEARANCES Allow adequate room to work with tools A minimum of 25mm clearance around the water heater is required An additional 30mm is required for relief valve removal 80mm for access cover removal and 400mm for element removal You should be able to read the information on the rating plate and all informat...

Page 7: ...ing valves are not supplied with Water Heaters PUMP LIMITS The SP 4002 system has a head limit of 6 meters A different model pump available from SOLARPOWER will be required to maintain water flow through the solar collectors for heads greater than 6 meters TANK WATER SUPPLY SolarPower water heaters are not recommended for use with a tank water supply unless a pressure pump has been fitted Minimum ...

Page 8: ... 2 Storey Homes in some installations may require the fitting of a non return valve in the solar line after the pump SolarPower recommends the installation of a inch swing check valve in the solar pump line to prevent the backflow of air from the panels into the pump which can cause cavitation of the pump the next time it starts Dual spring check valves are not to be installed as the pump does not...

Page 9: ...r heater a barrel union must always be provided at the cold water inlet solar hot water inlet and hot water outlet on the water heater to allow for disconnection of the water heater The pipe work must be cleared of foreign matter before connection All pipe fittings must be assembled using two spanners do not exert excessive amounts of torque on the pipes or water heater fittings ...

Page 10: ...ed the pipe work downstream of the relief valve be capable of carrying water exceeding 95ºC Failure to observe this precaution may result in damage to pipe work and property Should this pipe become obstructed eg squashed kinked or blocked then the water heater may be damaged due to internal pressure 4 CONNECTIONS ELECTRICAL NOTE Power must not be turned on until the solar storage tank is filled wi...

Page 11: ...running 2 short flashes Sensor fault pump off As this LED output is shared with the communications output when the LED is on continuously there will be a short blink every 2 seconds This small perturbation lasts for approximately 31ms Temperature Deg C 5 0 5 25 40 60 80 100 110 Resistance K Ohms 42 49 32 75 25 45 10 5 32 2 49 1 26 0 682 0 513 This chart outlines the resistance of temperature probe...

Page 12: ... has had time to warm up as the air bubbles can cause spurting from the taps Also check the Solar piping for leaks leaks will significantly decrease the performance of the heater Check pump speed is set to HIGH for a two story house and MEDIUM for a single story house Complete SolarPower Installation Report Sheet and return to SolarPower for the REC s Claim to be approved Switch on the electrical ...

Page 13: ...00kPa a pressure limiting valve must be fitted before the inlet of the heater rated at 600kPa HOW HOT SHOULD THE WATER BE When operated in a domestic situation the system s outlet temperature should be between 50o C and 80o C During periods of low solar energy gain the water temperature can be boosted by the thermostatically controlled electric booster heating unit The water heater features a trad...

Page 14: ...g unit not operating Inspect the isolating switch marked HOT WATER in the meter box and ensure it is turned ON Check the electrical tariff to which the unit is connected If the unit is connected to an Off Peak tariff remember heating hours are restricted Collectors shaded If trees or other objects shade the solar collectors or if the glass is dirty the effectiveness of the solar collectors will be...

Page 15: ...owing points Is the relief valve running excessively Are you using more hot water than you think Is there a leaking hot water pipe dripping hot water tap etc Even a small leak will waste a surprising quantity of hot water and energy Replace faulty tap washers and have your plumber rectify any leaking pipe work Are you using the booster heating unit properly Consider recent changes to your hot wate...

Page 16: ...ese devices are fitted and are in working order The WARRANTY can become void if relief valve or thermostat is tampered with or if the installation is not in accordance with these instructions SOLAR COLLECTOR GLASS Ensure the glass on your solar collectors is free of dust salt spray or any other matter which may reduce the effectiveness of the solar collectors Hose or wash the collector glass with ...

Page 17: ...eveland Redland Bay Point Lookout Ormiston Mount Cotton Alexandra Hills Victoria Point Birkdale Capalaba And Morton Bay islands and Bundaberg Moore Park Bargara and Yeppoon Notwithstanding the foregoing comment this does not imply or infer in any way that the water mentioned in the above locations does not meet drinking water requirements and is safe to drink NOTE WATER HEATERS NOT INSTALLED IN AC...

Page 18: ...y be implied or imposed on the Company by virtue of the Trade Practices Act 1974 or any other statute rule or regulation except for the extent to which the Company is lawfully entitled SolarPower warrants the SP4002 SOLAR HOT WATER SYSTEM hereinafter called the SYSTEM against manufacturing defects faulty materials and or workmanship upon the following terms A Twelve 12 Month Comprehensive Warranty...

Page 19: ...here it is found that the SYSTEM does not suffer a defect where the complaint is related to solid matter lodging under valve seats where there is a failure of water supplies electrical supplies or the result of extreme water pressure or thermal input 7 This warranty does not cover the SYSTEM where the SYSTEM is located in a position that does not comply with either the SolarPower installation inst...

Page 20: ...h Issued 01 August 2008 NOTE 2 Storey homes may require a single check valve fitted after the pump on the solar cold line to prevent cavitation in the pump DO NOT use dual check valves for this purpose as the pump will not have enough pressure to open the valve ...