background image

 

 

 

SoLED W840 User Manual Version 4.1 051915

  

PRELIMILARY

 

 

 

F

IXTURE 

M

OUNTING 

/

 

R

IGGING

 

 

Orientation 

 

Solaris LED fixtures may be mounted in any position.  Always make sure there is adequate room for ventilation.  

Do not obstruct the unit’s vents. 

 

Support Stand 

 

Always use a professional stand rated to support weight greater than the SoLED weight (4.77 lb. / 2.15 

kg).  Attach a TVMP spigot to the yoke of the SoLED and mount on the stand.

 

 

Rigging – 

Always consult a qualified rigging specialist before suspending any fixture 

overhead. 

 

Use ProBurger

®

 couplers or equivalent C- or O-type clamps for attaching to truss.  Do not 

obstruct vents.  Adjust the fixture angle by loosening both knobs and tilting the fixture as 

needed.  After establishing the desired position, retighten both knobs.  

 

 

Always use safety cables! 

  When selecting installation location, consider routine maintenance. 

  Never mount fixture where it will be exposed to moisture, high humidity, extreme 

temperatures, or restricted ventilation. 

 

 

 

3.

 

O

PERATING 

I

NSTRUCTIONS

 

 

C

ONTROL 

P

ANEL 

N

AVIGATION

 

 

Access control panel functions via four control panel buttons surrounding the LCD display.  Buttons are indicated 

by a concentric circle. 

 

The control panel LCD display shows the menu items selected from the menu map (page 8).  When a menu 

function is selected, the display will show the first available option for the selected menu function.  To select a 

menu item, press 

<MENU>

 

 

 

 

 

Summary of Contents for SoLED W840

Page 1: ...V4 1 SoLED W840 USER MANUAL PRELIMINARY...

Page 2: ...NG 5 DMX DATA CABLE 5 CABLE CONNECTORS 5 3 PIN TO 5 PIN CONVERSION CHART 6 SETTING UP A DMX SERIAL DATA LINK 6 FIXTURE MOUNTING RIGGING 7 3 OPERATING INSTRUCTIONS 7 CONTROL PANEL NAVIGATION 7 MENU MAP...

Page 3: ...parts are present and in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear to be damaged from shipping or if the carton itself shows signs of...

Page 4: ...onnel Contact the nearest authorized technical assistance center Only OEM spare parts should be used Do not connect the device to a dimmer pack Make sure power cord is never crimped or damaged Never d...

Page 5: ...digital DMX signal DMX DATA CABLE Use a ProPlex DMX cable or equivalent which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over lon...

Page 6: ...ignal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Do not use Do not use Do not use Do not use SETTING UP A DMX SERIAL DATA LINK 1 Connect the male 5 pin connector side of the DMX cable to the output female 5...

Page 7: ...Do not obstruct vents Adjust the fixture angle by loosening both knobs and tilting the fixture as needed After establishing the desired position retighten both knobs Always use safety cables When sele...

Page 8: ...u option To return to the top of the menu map or menu without changing the value press the X button MAIN MENU FUNCTIONS DMX Address DMX Address selection menu Control Control mode selection menu Manua...

Page 9: ...Intensity F3 DMX mode is set to 3 channels Int Dur Rate F4 DMX mode is set to 4 channels Int Dur Rate Eff Manual Manual control of fixture effects Stand alone function Int 0 255 Set strobe intensity D...

Page 10: ...ns to find the DMX Address submenu 3 Press button to access the DMX Address value change submenu 4 Use UP and DOWN buttons to set necessary DMX Address value e g DMX Address 1 5 Use button to confirm...

Page 11: ...open the Main Menu 2 Use UP and DOWN buttons to find the Control submenu and press button 3 Now the Control submenu is opened 5 Choose one of these three operating modes 6 When new mode is confirmed...

Page 12: ...6 42 16 Mar Ramp up 43 85 17 33 Ramp down 86 128 34 50 Ramp up down 129 171 51 67 Random 172 214 68 84 Lightning 215 250 85 97 Spikes 251 255 98 100 DC Mode Override v 4 0 software or higher SPECIAL E...

Page 13: ...safe operating levels The fixture allows full output bursts if the temperature is within operating specifications MANUAL MODE Manual Mode allows control of SoLED without a controlling device In this m...

Page 14: ...172 214 68 84 Lightning 215 251 252 255 85 97 98 100 Spikes DC mode Override To edit values do following Use UP and DOWN buttons to select the strobe function to be modified Press button Press UP and...

Page 15: ...u shows all possible sensor values 1 Press and hold MENU button to open the Main Menu 2 Use UP and DOWN buttons to find the Measure submenu and press button Indicated are Input voltage Uin frequency F...

Page 16: ...PRELIMILARY 16 3 To change temperature scale from Celsius to Fahrenheit press UP or DOWN buttons THERMOMETER 1 Press and hold MENU button to open the Main Menu 2 Use UP and DOWN buttons to find the Th...

Page 17: ...ts to the DMX IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a lighting console communicates to each fixture Use an order that provides...

Page 18: ...ct in the field and any associated labor charges must be authorized in advance by TMB Freight costs on warranty repairs are split 50 50 Customer pays to ship defective product to TMB TMB pays to ship...

Page 19: ...US Phone 1 818 899 8818 Fax 1 818 899 8813 UK Phone 44 0 20 8574 9700 Fax 44 0 20 8574 9701 e mail tmb info tmb com web www tmb com 24 7 TECHNICAL SUPPORT TMB US Canada 1 877 TMB DUDE 1 877 862 3833 T...

Page 20: ...840W POWER CONNECTORS IN POWERCON 20A BLUE LIGHT SOURCE LED COUNT 84 CREE XP L LED S COLORS WHITE COLOR TEMPERATURE 5700K BEAM SPREAD 100 THERMAL MAX AMBIENT TEMPERATURE 40 C MIN AMBIENT TEMPERATURE...

Reviews: