SoLED W840 User Manual Version 4.1 051915

  

PRELIMILARY

 

 

13 

 

 

DC MODE Override:  

Lamp changes to 2400Hz flicker-free mode.  This mode uses the intensity 

channel of F4 mode to scale the intensity from 0 – 100%. Strobe Rate, Duration, and Effects are 

bypassed. Fixture will remain at a constant intensity unless it senses a thermal limit being hit and will 

throttle itself down in intensity back to operational specs. This mode will exhibit stepping, especially in 

the lower range of the intensity channel due to the nature of the near pure-DC operation of the leds.  

 

 

NOTE:  If fixture senses over-limit thermal operation, smart-limiting activates and throttles the fixture 

down to safe operating levels.  The fixture allows full output bursts if the temperature is within operating 

specifications. 

 

 

M

ANUAL 

M

ODE

 

 

Manual Mode allows control of SoLED without a controlling device.  In this menu, manually select strobe 

intensity, duration, and rate between strobe and other effects (see page 12).  Manual Mode is a stand-alone 

mode; values are saved if power is interrupted.  “Reset” will clear Manual Mode values. 

 

Manual function includes four settings:  

 

Int

 (intensity of strobe) 

 

Dur

 (duration of strobe) 

 

Rate

 (duration between flashes) 

 

Eff 

(special effect channel (see table on page 14) 

 

1)  Press and hold 

<MENU>

 button to open the Main Menu. 

2)  Use 

<UP>

 and 

<DOWN>

 buttons to find the Manual submenu and press the 

button. 

 

3)  Manual Mode submenu will open.  

 

Int 

(Intensity) 

 

Dur 

(Duration)

 

 

Rate 

 

Eff 

(Effects, FX) 

 

 

 

 

 

 

 

4)  Manual Mode submenu will open.  

 

Int 

(Intensity) 

 

Dur 

(Duration)

 

 

Rate 

 

Eff 

(Effects(FX) 

 

Summary of Contents for SoLED W840

Page 1: ...V4 1 SoLED W840 USER MANUAL PRELIMINARY...

Page 2: ...NG 5 DMX DATA CABLE 5 CABLE CONNECTORS 5 3 PIN TO 5 PIN CONVERSION CHART 6 SETTING UP A DMX SERIAL DATA LINK 6 FIXTURE MOUNTING RIGGING 7 3 OPERATING INSTRUCTIONS 7 CONTROL PANEL NAVIGATION 7 MENU MAP...

Page 3: ...parts are present and in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear to be damaged from shipping or if the carton itself shows signs of...

Page 4: ...onnel Contact the nearest authorized technical assistance center Only OEM spare parts should be used Do not connect the device to a dimmer pack Make sure power cord is never crimped or damaged Never d...

Page 5: ...digital DMX signal DMX DATA CABLE Use a ProPlex DMX cable or equivalent which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over lon...

Page 6: ...ignal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Do not use Do not use Do not use Do not use SETTING UP A DMX SERIAL DATA LINK 1 Connect the male 5 pin connector side of the DMX cable to the output female 5...

Page 7: ...Do not obstruct vents Adjust the fixture angle by loosening both knobs and tilting the fixture as needed After establishing the desired position retighten both knobs Always use safety cables When sele...

Page 8: ...u option To return to the top of the menu map or menu without changing the value press the X button MAIN MENU FUNCTIONS DMX Address DMX Address selection menu Control Control mode selection menu Manua...

Page 9: ...Intensity F3 DMX mode is set to 3 channels Int Dur Rate F4 DMX mode is set to 4 channels Int Dur Rate Eff Manual Manual control of fixture effects Stand alone function Int 0 255 Set strobe intensity D...

Page 10: ...ns to find the DMX Address submenu 3 Press button to access the DMX Address value change submenu 4 Use UP and DOWN buttons to set necessary DMX Address value e g DMX Address 1 5 Use button to confirm...

Page 11: ...open the Main Menu 2 Use UP and DOWN buttons to find the Control submenu and press button 3 Now the Control submenu is opened 5 Choose one of these three operating modes 6 When new mode is confirmed...

Page 12: ...6 42 16 Mar Ramp up 43 85 17 33 Ramp down 86 128 34 50 Ramp up down 129 171 51 67 Random 172 214 68 84 Lightning 215 250 85 97 Spikes 251 255 98 100 DC Mode Override v 4 0 software or higher SPECIAL E...

Page 13: ...safe operating levels The fixture allows full output bursts if the temperature is within operating specifications MANUAL MODE Manual Mode allows control of SoLED without a controlling device In this m...

Page 14: ...172 214 68 84 Lightning 215 251 252 255 85 97 98 100 Spikes DC mode Override To edit values do following Use UP and DOWN buttons to select the strobe function to be modified Press button Press UP and...

Page 15: ...u shows all possible sensor values 1 Press and hold MENU button to open the Main Menu 2 Use UP and DOWN buttons to find the Measure submenu and press button Indicated are Input voltage Uin frequency F...

Page 16: ...PRELIMILARY 16 3 To change temperature scale from Celsius to Fahrenheit press UP or DOWN buttons THERMOMETER 1 Press and hold MENU button to open the Main Menu 2 Use UP and DOWN buttons to find the Th...

Page 17: ...ts to the DMX IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a lighting console communicates to each fixture Use an order that provides...

Page 18: ...ct in the field and any associated labor charges must be authorized in advance by TMB Freight costs on warranty repairs are split 50 50 Customer pays to ship defective product to TMB TMB pays to ship...

Page 19: ...US Phone 1 818 899 8818 Fax 1 818 899 8813 UK Phone 44 0 20 8574 9700 Fax 44 0 20 8574 9701 e mail tmb info tmb com web www tmb com 24 7 TECHNICAL SUPPORT TMB US Canada 1 877 TMB DUDE 1 877 862 3833 T...

Page 20: ...840W POWER CONNECTORS IN POWERCON 20A BLUE LIGHT SOURCE LED COUNT 84 CREE XP L LED S COLORS WHITE COLOR TEMPERATURE 5700K BEAM SPREAD 100 THERMAL MAX AMBIENT TEMPERATURE 40 C MIN AMBIENT TEMPERATURE...

Reviews: