background image

3

SOLARIS® HITMAN230™

 

WARNING!

Read the safety precautions in this manual before installing 

operating or servicing this product.

SAFETY NOTES

Read all the following Safety Notes before working with this product. 

These notes include important information about the installation, us

-

age, and maintenance of this product.

This product contains no user-serviceable parts. Any reference to ser

-

vicing in this User Manual will only apply to properly trained GLOW® 

Professional certified technicians. Do not open the housing or attempt 

any repairs.

All applicable local codes and regulations apply to proper installation of 

this product.

PERSONAL SAFETY

· Avoid direct eye exposure to the light source while the product is on.

· Always disconnect this product from its power source before servicing.

· Always connect this product to a grounded circuit to avoid the risk of 

electrocution.

· Do not touch this product’s housing during operation because it may 

be very hot.

MOUNTING & RIG-

GING

· This product is for indoor use only! To prevent risk of fire or shock, do 

not expose this product to rain or moisture. (IP20)

· Mount this product in a location with adequate ventilation, at least 20 

in (50 cm) from adjacent surfaces.

· Make sure there are no flammable materials close to this product while 

it is operating.

· Always carry this product by the handles. Do not carry from the head.

· When hanging this product, always secure to a fastening device using 

a safety cable.

SAFETY INFORMATION

 

Summary of Contents for HITMAN 230

Page 1: ...USER MANUAL...

Page 2: ...MP LIFE SPAN 5 INSTALLATION 6 7 AC POWER 7 FIXTURE OVERVIEW 8 DMX DATA LINK 9 CONNECTING AND USING DMX DATA LINK 9 FIXTURE OPERATION 10 11 TOKENS 12 FIXTURE MENU STRUCTURE CHART 13 DMX MODES CHARTS 14...

Page 3: ...ERSONAL SAFETY Avoid direct eye exposure to the light source while the product is on Always disconnect this product from its power source before servicing Always connect this product to a grounded cir...

Page 4: ...enses LED lights or cables Have the damaged parts replaced by an authorized technician at once Do not cover the ventilation slots when operating to avoid internal overheating Do not aim this product t...

Page 5: ...he fixture 2 Unpack and ensure that there is no transportation damage before using the fixture Never attempt to operate a damaged fixture 3 If the fixture is not going to be hard wired to a mains supp...

Page 6: ...mage if it falls secure it as directed below with a securely anchored safety cable that will hold the fixture if the pri mary fastening method fails MOUNTING THE FIXTURE ON A TRUSS The fixture can be...

Page 7: ...on the power cable If you replace power plug on the power cable install a grounding type earthed plug with integral cable grip that is rated minimum 250 V 5 A The fixture has an auto ranging power sup...

Page 8: ...g the fixture DMX personality Beam Angle Weight and Power Supply 2 Jog Scrolling Wheel and button 3 Digital Screen for viewing the menu 1 2 3 FIXTURE OVERVIEW 4 DMX IN DMX OUT 5 PowerCon Power In Conn...

Page 9: ...rol of a fixture is required it must have its own DMX channels Fixtures that are required to behave identically can share the same DMX address and channels To add more fixtures or groups of fixtures w...

Page 10: ...un mode and return to DMX control mode Select Exit and press once on the jog wheel to return to main menu SOUND TO LIGHT MODE by selecting Run Test Interface option in the menu you can turn on Sound R...

Page 11: ...ameter of the fixture can be manually adjusted using the adjust interface Gobo Color Focus Prism Pan Tilt can be manually adjusted by changing the value 000 default to a value between 1 255 Select Exi...

Page 12: ...ing Solaris fixtures The TOKENS are located above the digital screen on the back panel of the fixture This token indicates the maximum amount of power consumption Displays in Watts This token indicate...

Page 13: ...000 512 Adjust Focus Default value 001 000 512 Adjust Prism Default value 000 000 512 Adjust X Default value 000 000 512 Adjust Y Default value 000 000 512 Adjust Exit Run Test Auto Run OFF ON Auto r...

Page 14: ...T GREEN LAVENDER LAVENDER LAVENDER PINK PINK PINK YELLOW YELLOW YELLOW MAGENTA MAGENTA MAGENTA CYAN CYAN CYAN CTO 260 CTO 260 CTO260 CTO 190 CTO 190 CTO 190 CTB 8000 CTB8000 CTB8000 BLUE BLUE BLUE WHI...

Page 15: ...2 shake fast speed Gobo3 shake slow speed Gobo3 shake fast speed Gobo4 shake slow speed Gobo4 shake fast speed Gobo5 shake slow speed Gobo5 shake fast speed Gobo6 shake slow speed Gobo6 shake fast spe...

Page 16: ...10 PAN 0 255 Pan movement range 540 Degrees 11 PAN FINE 0 255 12 TILT 0 255 Tilt movement range 270 Degrees 13 TILT FINE 0 255 14 FUNCTION 0 11 12 24 25 37 38 50 51 62 63 255 Unused range Fast defaul...

Page 17: ...outdoor events for example If one or more of these factors is present inspect fixtures within their first 100 hours of oper ation to see whether cleaning is necessary Check again at frequent intervals...

Page 18: ...fects instant open and black out Dimmer 0 100 Linear Dimmer Dynamic Effect Color Wheel 14 colors plus open rotation with variable direction and speed Static Gobo Wheel 17 gobos plus open wheel rotatio...

Page 19: ...Power Supply Auto Ranging Electronic Switch Mode INCLUDED ITEMS 3 ft Power Con Power Cable User Manual Specifications are subject to change without notice For latest product specifications see www Glo...

Page 20: ...LOSS OCCASIONED BY THE USE OF INABILITY TO USE OR RELIANCE ON THE INFORMATION CONTAINED IN THIS MANUAL THE GLOW LOGO THE SOLARIS LOGO THE GLOW PROFESSIONAL NAME THE SOLARIS PROFESSIONAL NAME AND ALL O...

Reviews: