SAFETY, INSTALLATION, AND OPERATIONS MANUAL 

© The Solaria Corporation 

Contents subject to change without notice.

U.S. and International patents issued and pending  

Document PSC-0004 Rev 02, November 2010

4 of 12

 

3.

  ELECTRICAL INSTALLATION

 CAUTION: AVOID ALL ELECTRICAL HAZARDS WHEN INSTALLING, WIRING, 

OPERATING, AND MAINTAINING A MODULE OR MODULE ARRAY.  

Refer to Section 2 for more information.

  The electrical installation must be in accordance with CSA C22.1, Safety Standard for Electrical 

Installations, Canadian Electrical Code, Part 1.

  

Recommended Wire:

 Single conductor cable, type USE-2 (non-conduit) 10-12AWG (4-6mm

2

) with 

minimum 90

º

C rating and sunlight UV protected.

  

Series Connection:

 Modules may be wired in series to produce the desired voltage output. DO NOT 

exceed the maximum system voltage indicated on the module label.

  

Parallel Connection:

 Modules may be combined in parallel to produce the desired current output. 

It may be necessary to fuse each series string or module prior to combining with other strings. DO 
NOT exceed the maximum system voltage indicated on the module label.

  Connection cables and wiring must be supported with cable ties and clips to the module support 

structures. DO NOT use module junction boxes to support cables and wiring.

  Under normal conditions, a photovoltaic module is likely to experience conditions that produce more 

current and/or voltage than reported at Standard Test Conditions. Accordingly, the values of Isc and 
Voc marked on the module should be multiplied by a factor of 1.25 when determining component 
voltage ratings, conductor capacities, fuse sizes, and sizes of controls connected to the PV output.

  An additional multiplying factor of 125% (80% de-rating) may be applicable. Refer to section 690-8 

of the National Electric Code (NEC) for more information.

  All Solaria modules are equipped with factory locking connecting cables. Modules have been 

designed to be easily connected. DO NOT disconnect the locking connectors  
under load. 

The proper procedure to disconnect the module locking connectors is as follows: 

1.  Turn off of the inverter(s).
2.  Shut off the module DC disconnect(s). 
3.   Disconnect the locking connectors using the Multi-Contact tool set, Part Number PV-MS. 

To re-install:

1.  Connect the module locking connectors.
2.  Turn on the module DC disconnect(s).
3.  Turn on the inverter(s). 

 

 

4-color

2-color

1-color

4-color

1-color

Summary of Contents for 210W

Page 1: ...color color color color color Solaria Frameless 230W 220W 210W Module Series Mono crystalline Solar Panels 156x156mm Cells SAFETY INSTALLATION AND OPERATIONS MANUAL North America and Europe...

Page 2: ...igher than 240W where general contact access is anticipated modules qualified for safety through EN IEC 61730 1 and 2 within this application class are considered to meet the requirements for Safety C...

Page 3: ...HE FOLLOWING PRECAUTIONS TO AVOID FIRE HAZARDS Refer to your local authority for guidelines and requirements for building and structural fire safety The roof construction and installation may affect t...

Page 4: ...the module label Connection cables and wiring must be supported with cable ties and clips to the module support structures DO NOT use module junction boxes to support cables and wiring Under normal c...

Page 5: ...module in a string of modules causes reverse voltage across the shaded cells This results in current being forced through the shaded cells causing module heating and severe power loss The bypass diode...

Page 6: ...he application z z Clearance of 7mm or more between frameless modules is required to allow for thermal expansion of the tracker rack mounting hardware z z The back surface of the module must always be...

Page 7: ...mm from the edge See following figure for allowed clip locations Note the following z z For each module use four sets of stainless steel hardware each set 5 16 18 hex head bolt at 8mm diameter hex nut...

Page 8: ...nses are in the North South direction This orientation is called Landscape Mount It positions the cell lenses parallel to the axis of rotation z z Dual Axis Tracker Modules should be tracker open rack...

Page 9: ...or expense arising out of or in any connection with such installation operation use or maintenance of the modules z z The Solaria Corporation assumes no responsibility for any infringement of patents...

Page 10: ...3 81 Current at Pmax A 6 71 6 46 6 21 Cells Monocrystalline Bypass Diodes 5 1 per String 5 Strings Ratings 15 Amps each Max Vrrm 45 Volts Type ZJRH PVS105 Isc 3 10 mA C Imp 4 10 mA C Voc 166 5 mV C Vm...

Page 11: ...Solaria Corporation Contents subject to change without notice U S and International patents issued and pending Document PSC 0004 Rev 02 November 2010 11 of 12 8 FRAMELESS MECHANICAL SPECIFICATIONS z z...

Page 12: ...t CA 94555 United States of America T 1 510 270 2500 F 1 510 793 8388 Solaria Germany Oranienburger Strasse 23 D 10178 Berlin Germany T 40 30 233 297 97 F 49 30 275 748 56 Solaria India 202 SSH Pride...

Reviews: