P Position
duration
Function
Comments
Switch moved
to P for
less
than 5
seconds
, then
released.
Displays (via
LEDs) production
information for 5
seconds, or error type
indications (if exist)
for 5 seconds.
Activates the Wi-Fi
access point for
connecting to the
SetApp
While the switch is in P, all
LEDs are ON.
When the switch is released
all LEDs turn OFF for 0.5 sec
and then display the
production or error
indication.
Switch moved
to P for
more
than 5
seconds
, then
released.
Starts pairing
Pairing is indicated by all 3
LEDs blinking
simultaneously.
LEDs
LEDs
: three LEDs indicate, by color and state (on/ off/ blinking
(1)
/
flickering
(2)
/alternating
(3)
), different system information, such as errors or
performance indications.For more information, refer to
https://www.solaredge.com/leds
The main LED indications are:
Blue ON - the inverter is communicating with the
monitoring platform
Green ON - the system is producing
Green blinking - AC is connected but the system is not producing
Red ON - system error
(1)Blinking = Turns ON and OFF for the same duration
(2)Flickering = Turns ON for 100 mS and turns OFF for 5 seconds
(3)Alternating = alternate LED flashes
-
Three
Phase
System
Installation
Guide
MAN-01-00527-1.
2
30