![SolarEdge RESU10H Prime Series Installation Manual Download Page 78](http://html1.mh-extra.com/html/solaredge/resu10h-prime-series/resu10h-prime-series_installation-manual_1313714078.webp)
SE3000H-US
SE3800H-US
SE6000H-US
SE7600H-US
SE10000H-US
SE11400H-US
UNITS
Supported Communication Interfaces
RS485, Ethernet, Cellular
(1)
, Wi-Fi (optional),SolarEdge Energy Net (optional)
Revenue Grade Metering, ANSI C12.20
Built - in
(4)
Integrated AC, DC and Communication
Connection Unit
Yes
Inverter Commissioning
With the SetApp mobile application using built-in Wi-Fi Access Point for local
connection
DC Voltage Rapid Shutdown (PV and
Battery)
Yes, according to NEC 2014, NEC 2017 and NEC 2020 690.12
STANDARD COMPLIANCE
Safety
UL1741, UL1741 SA, UL1741 PCS, UL1699B, UL1998, UL9540, CSA 22.2
Grid Connection Standards
IEEE1547, Rule 21, Rule 14H
Emissions
FCC part 15 class B
INSTALLATION SPECIFICATIONS
AC Output and EV AC Output Conduit
Size / AWG Range
1'' maximum / 14-4 AWG
DC Input (PV and Battery) Conduit Size /
AWG Range
1'' maximum / 14-6 AWG