(red circles below grounding points).
is placed under the module frame.
www.solarackusa.com
Step 6
Fasten and install at locations where two solar
modules meet. Location of mid clamps from rail
end should comply with module manufacture
guidelines. Torque to 6 ft lb.
Once Mid Clamps are fasten the Stainless Steel
Flung bolt will remove the anodization coating from
the module frame for bonding while the grounding
nut penetrates the bottom portion of the module frame.
Page 20
Step 7
Insert SolaRack Integrated Grounding & Bonding
UMG End Clamp by sliding it into the rail
upper opening. Make sure the lip at the front
of the End Clamp is placed below the Module
frame. Make sure the grounding nut sharp end
Top Grounding
Bottom Grounding
Top Grounding
Bottom Grounding
© 2018 SOLARACK INC. VR2.1