![Solar Stik Li Expander Pak 2400 Quick Start Manual Download Page 8](http://html1.mh-extra.com/html/solar-stik/li-expander-pak-2400/li-expander-pak-2400_quick-start-manual_1313497008.webp)
Solar Stik
®
Technical Bulletin 2
Effective Date 20150831
800.793.4364
www.solarstik.com
© 2019 Solar Stik Inc.
All Rights Reserved. Solar Stik is a registered trademark of Solar Stik Inc.
SS20190717
Item #
Item to be
Inspected
Interval
at
91-140
ºF
(33-60
ºC)
Storage
Temp
Interval at
77-90 ºF
(< 25-32 ºC)
Storage
Temp
Procedures
Non-mission
Capable
4
In-storage
maintenance
charging
Q
S
3
1. Charge Li Expander Paks
for 24 hours at 29.0 V.
Follow the instructions for
the lithium battery charger
used.
2. Charge until the Battery
Status LED on all Li
Expander Paks is flashing
green (if flashing red to
begin with).
3. If the Battery Status LED
flashes red on any Li
Expander Pak after 24
hours, continue charging
all Li Expander Paks for
another 24 hours.
~If any Li Expander
Pak has a red-flash
Battery Status LED
after 48 hours of
charging OR if the
LED emits no light
after charging,
contact Solar Stik
Technical Support.
Continued from previous page