Input

120 VAC 

50 A

PSS-G AES Cable Set case

2.  The Adapter Cables are sold 

separately* (figures 3 and 4) and can 

be stored with the AES in the Cable 

Case (figure 2). 

1.  Slide the stack of PAM Solar Array Cases on the left, to the 

left (red arrow; figure 2) to expose the 120 VAC L5-50 Port 

on the PRO-Verter 7000.

Figure 2 - PAM cases moved/50 A Port accessible

Figure 3 - 50 A to 30 A Adapter Cable

Figure 4 - 30 A to 15 A Adapter Cable

Figure 5 - Adaptor Cables attached to the  AC 

input connection on the PRO-Verter 7000

3.  Connect the 30 A and/or 15 A adaptor 

to the PRO-Verter 7000 50 A port 

(Figure 5). 

The AES components should be arranged so that the necessary ports are accessible. Two adaptor 

cables (figures 3 and 4) allow connection of a 120 VAC 15 A power cord into the 120 VAC 50 A Port 

on the left-hand side of the PRO-Verter 7000. The method described here will work no matter how 

the individual components are arranged as long as they are close enough for the cables to reach 

between the ports.

Page 3 of 8

*50A to 30A Adapter Cable Item # 07-1001182
*30A to 15A Adapter Cable Item # 07-1001181

Summary of Contents for Li Expander Pak 2400

Page 1: ...omenon common to all rechargeable batteries This Technical Bulletin provides easy instructions to ensure that the Li Expander Pak 2400s function optimally in all environments Conversely failure to fol...

Page 2: ...f steps that will allow simultaneous charging of all ten 10 batteries of a single system using shore power or generators as the charging source The basic system charging connection scheme is shown in...

Page 3: ...Port accessible Figure 3 50 A to 30 A Adapter Cable Figure 4 30 A to 15 A Adapter Cable Figure 5 Adaptor Cables attached to the AC input connection on the PRO Verter 7000 3 Connect the 30 A and or 15...

Page 4: ...ble for each as shown in the diagram above 5 Connect the two 2 Inter Connect Strips to the 24VDC IN ports on the front left side of the PRO Verter 7000 using two 2 5 Inter Connect cables as shown in t...

Page 5: ...s indicator will be GREEN NOTICE Extending the charge times beyond the minimum will not result in damage to the Li Expander Pak 2400s However they should not be left to charge indefinitely Minimum cha...

Page 6: ...charging more frequently and maintaining the Expander Paks in a fully charged state increases as the storage temperature increases The higher the storage temperature the faster the Li Expander Pak 240...

Page 7: ...from the exterior and ports 3 Close all unused port covers If the case is broken or split or if ports are damaged contact Solar Stik Technical Support for advice on how to proceed 2 Expander Pak Stat...

Page 8: ...harging Q S3 1 Charge Li Expander Paks for 24 hours at 29 0 V Follow the instructions for the lithium battery charger used 2 Charge until the Battery Status LED on all Li Expander Paks is flashing gre...