June 2020
|
Solar Stik
®
, Inc.
44
|
24VDC PRO-Verter 5000-120 AGS Operator Manual
04K Gen 100% SOC
Start Days = Off
Set
Gen 100% SOC
Start Days = Off
Set 100% SOC Run
Hour = 1:00P
Set 100% SOC Run
Minute = 0:45P
Set 100% SOC Run
AM-PM = 0:00P
Set
Gen 100% SOC
Days = 1-255 Days
Set 100% SOC Run
Hour = 12:00P
Set 100% SOC Run
Minute = 0:00
Set 100% SOC Run
AM-PM = 0:00A
Default Off
Range: Off, 1-255
continued
SETUP
05 BMK Setup
05A Charge Eff
Auto
05B AmpHour Size
360 AH
05A Charge Eff
Range: Auto, 50-99%
05B AmpHour Size
Range: 200-2500
Default=Auto
BMK Setup Notes
The AmpHour Size value should be
set according to the total capacity
of the battery bank minus 10%. For
example, one 24VDC Li Expander
Pak 2400 is 100 Ah. The minimum
setting allowed on the PRO-Verter
is 200 Ah.
The state of charge reported by
the 24VDC PRO-Verter 5000 will
be accurate only if the total battery
bank size is at least 200 Ah.
SETUP Button Menus continued
Setup: 04 AGS Setup, 05 BMK Setup