background image

7

Solar module mounting instructions

Mono S3 

 Mono S2 

 M series 

 P series

Correct handling of AR glass modules

The nano-porous coating on the glass surfaces of 

the solar module reduces reflection losses. Compa

-

red to uncoated glass, a deviation of the irradiation 

angle  from  the  vertical  can  result  in  an  angle-de

-

pendent transmission of up to 2 % more power. To 

maintain this effect and to avoid visual impairments, 

we urgently recommend observing the following in

-

structions:

 

Handle the modules with care due to the coa

-

ted glass.

 

Handle the modules with care when unpacking 

and mounting. We recommend only touching 

the  surfaces  with  clean  gloves  because  the 

special reflective properties make light soiling 

easier to detect. Especially grease and oil are 

visible even in small quantities and can influ

-

ence the transmission.

 

 We advise against attaching stickers or labels 

to the coated surface. Depending on the ma

-

terial used, this can result in very fine residues 

that are difficult to remove.

 

 In rare cases, there may be visible white resi

-

dues of the coating fluid and colour variations 

in the edge area (≤ 5 mm). These are fully fun

-

ctional  modules  and  there  is  no  reduction  in 

quality.

 

 If it is necessary to clean the modules due to 

heavy  soiling,  we  recommend  the  following 

procedure:

+ Clean the modules when they have cooled down 

(e.g. during the morning hours)

+ For moderate to strong residues, we recommend 

cleaning with lukewarm, de-mineralised water and 

clean, lint-free cotton cloths, microfibre cloths or pa

-

per towels

+  For  particularly  heavy  and  stubborn  soiling,  we 

recommend detergents containing surfactants

 

+ Avoid  cleaning  with  strong  acids,  alkaline  solu

-

tions,  petrol-based  cleaners,  steam  and  hot  clea

-

ners, cleaners with silicone oils, fluorides or waxes, 

polishes, alkaline cleaners and cleaners with scou

-

ring agents and high-pressure cleaners

Ensuring comprehensive fire protection

Under  certain  circumstances,  the  installation  of 

roof-mounted systems can have an impact on the 

fire  safety  of  a  building.  Improperly  executed  ins

-

tallations in particular can lead to a fire hazard. Th

-

erefore always install the modules of a roof-moun

-

ted system above a fire-resistant substrate. As the 

modules are not explosion-proof equipment, do not 

install  the  modules  near  highly  flammable  gases 

and vapours, e.g. in the vicinity of gas containers, 

paint spraying systems or filling stations. Also, do 

not install the modules next to naked flames and 

flammable materials.

Ensuring a suitable environment

The modules are primarily intended for use in mo

-

derate climatic conditions. Make sure they are not 

exposed  to  artificially  concentrated  sunlight,  sub

-

merged or continuously exposed to splashing water 

at their destination. There is a risk of corrosion if the 

modules are subject to exceptional loads of salts or 

sulphur.

Suitable installation situation

It is of utmost importance that the module meets the 

technical requirements of the overall system. The

-

refore, make sure that no damaging mechanical or 

electrical effects (e.g. overvoltage) are exerted on 

the  module  by  other  system  components.  When 

connected in series, only modules of the same am

-

perage may be used; when connected in parallel, 

only modules with the same voltage may be used. 

The modules may only be operated with the permis

-

sible system voltage; operation with a higher volta

-

ge is not intended.

Summary of Contents for M Series

Page 1: ...Solar modules Solar module mounting instructions Mono S3 Mono S2 M series P series ...

Page 2: ...ules are properly earthed 6 Special instructions for handling AR glass modules 7 Ensuring comprehensive fire protection 7 Ensuring a suitable environment 7 Suitable installation situation 7 Correct mounting location 8 Assuring yield through optimum alignment and inclination 8 Installing the module free from shade 8 Ensuring sufficient rear ventilation 8 Secure mounting 8 Instructions for installat...

Page 3: ...ull cells P series 72 full cells 60 full cells 120 half cells 72 full cells 120 half cells 120 half cells 60 full cells 60 full cells M series 72 full cells 144 half cells 60 full cells 120 half cells 72 full cells 120 half cells 120 half cells 60 full cells Mono S2 144 half cells 120 half cells 120 half cells Mono S3 ...

Page 4: ...modules is tested at an am bient temperature of 40 to 85 C This range should be observed The modules must not be exposed to excepti onal chemical loads e g emissions from ma nufacturing companies When connecting solar modules to power sto rage units the respective safety instructions of the manufacturer must be observed Attention Danger to life Danger to life from electric shock Solar modules gene...

Page 5: ...ass may be used in systems with unlimited accessibility SF Solar Factory GmbH Co KG modules of the Mono S2 M and P series which are qualified wi thin this application class according to EN 61730 meet the requirements of protection class II when installed in accordance with regulations Transport intermediate storage and safe unpacking The modules are sensitive technical components that require grea...

Page 6: ...rly earthed In accordance with the provisions of SF Solar Fa brik GmbH Co KG it is not necessary to earth the module frames and rack for trouble free operation To avoid the risk of electric shock e g from static charges as far as possible SF Solar Fabrik GmbH Co KG recommends having the installer carry out professional earthing If an external lightning protection device is availab le a technical s...

Page 7: ... detergents containing surfactants Avoid cleaning with strong acids alkaline solu tions petrol based cleaners steam and hot clea ners cleaners with silicone oils fluorides or waxes polishes alkaline cleaners and cleaners with scou ring agents and high pressure cleaners Ensuring comprehensive fire protection Under certain circumstances the installation of roof mounted systems can have an impact on ...

Page 8: ...e year and unhin dered exposure to sunlight should be ensured for several hours even on days when the calendar is unfavourable Ensuring sufficient rear ventilation Sufficient rear ventilation ensures that performan ce reducing heat accumulation can be avoided Secure mounting In order to mount the modules as intended they must each be securely fastened by at least four points Framed PV modules may ...

Page 9: ... guidelines of the inverter manufacturers Using suitable materials only The system may only be wired with special solar cables in accordance with DIN EN 50618 class 5 and suitable plugs It is of utmost importance that all materials used are in perfect electrical and mechanical condition Only use single core cables and select the appro priate conductor cross section to minimise the vol tage drop On...

Page 10: ...72 cells Mono S2 HC 144 cells Mono S3 HC 144 cells Z B B Solar module Mounting clamped 6x P series B 150 350mm Z vert zentriert M series Mono S2 M series HC B 150 350mm Z vert zentriert Mono S2 HC Mono S3 HC P series 72 cells B 200 240mm or B 320 360mm Z vert zentriert M series 72 cells Mono S2 72 cells Mono S2 HC 144 cells Mono S3 HC 144 cells B B B B Solar module Mounting clamped 4x P series B 0...

Page 11: ... is also important to ensure that the module is not connected to the generator field during operation The photoactive front side of the module should be covered as far as possible or face the ground during all work steps to keep the voltage low If all installation instructions are observed and the installation is carried out by a technical specialist the product guarantee of the modules remains in...

Page 12: ...lated by the Electrical and Electronic Equipment Act ElektroG which transposes the WEEE Direc tive into German law Please also observe country specific regulations It is possible that notification is required in the res pective country Note on liability and status of the instructions If there are deviations from the instructions con tained in this user information SF Solar Fabrik GmbH Co KG does n...

Page 13: ...13 Solar module mounting instructions Mono S3 Mono S2 M series P series 3 Notes ...

Page 14: ...ment Nr 2004M01 E Solar modules SF Solar Fabrik GmbH Co KG Im Gewerbegebiet 12 63831 Wiesen Germany Phone 49 0 6096 97007 90 Fax 49 0 6096 97007 28 E Mail info solar fabrik de Internet www solar fabrik de REFERENCE PROJECT ...