TROUBLE SHOOTING  

 

 

Heater does not come on, t in display

….The heater pre-set trip temperature IS ABOVE THE AMBIENT 

 

TEMPERATURE. This can be adjusted using the temperature set point potentiometer.

 

 

 

Heater does not come on, flashing DOT

…The controller is waiting for input from optional occupancy sensor 

or pushbutton. If your system does not utilize the occupancy sensor or a pushbutton, then wire jumper (factory 
installed) must be in place in PIR SENSOR INPUT on pins SIG IN and COM. If the jumper is not in place, 
controller will not operate. 

 

 

 

SPECIFICATIONS 

 

 

 

 

 

 

 

Max load at 20°C ambient   

 

 

 
Voltage  
Power Consumption    

  

Occupancy Sensor (option) 
Pushbutton Timer (option)  
Set Time Period   

  

 

 

Temperature Set point    

 

 

Factory Set Temperature trip point  

 

2 heater Installation      

 

 

Ambient Operating Temperature   

 

IP Rating   

  

  

 

 

Max Unit Operating Temperature  

 

 

 

Occupancy Sensor 

(optional) 

 

Operating Voltage   

  

 

 

Direction   

  

  

 

 

Detection   

  

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.0kW @ 208-240VAC or 
4.0kW @ 120VAC

 

120Vac or 208-/- 10%50/60Hz  
50mA 

 

See below

 

 

Momentary or Toggle 

 

1-60 minutes 
5°C to 25°C  
25°C 

 

Must be fitted in Parallel 

 

-20°C to 30°C 

 

IP65 

 

65°C 

 

12V dc 

 

90° Adjustable 

 

45’ (18 Meters) 

 

 

 

 

 

 

 

 

 

 

WARNING:  Solaira  SMaRT  34-DV  Variable  control  is  a  high  power 
electrical device and MUST ONLY BE INSTALLED BY A CERTIFIED 
ELECTRICIAN TO LOCAL AND NATIONAL ELECTRICAL CODE

 

 

 