Trouble Shooting
Temperature Set Point
Temperature set point allows user to control the
MINIMUM TEMPERATURE for heaters to come
on. If the ambient temperature is above the
pre-set level, the heater control will show "t" and
WIL NOT TURN ON. You can reduce the minimum
temperature to 5⁰C
Temperature Sensor Input
For local temperature sensor input and optional remote
temperature sensor input. The local temperature sensor
is included with all SMaRT 34-DV controllers. If the user
wishes NOT to use the temperature monitoring feature,
simply disconnect the temperature sensor.
FLASHING DOT ON CONTROL PANEL DISPLAY
If the controller is used WITHOUT OPTIONAL OCCUPANCY SENSOR (PIR, Passive Infrared Sensor) or
Pushbutton timer, then "wire jumper" must be installed in pins SIG and COM as shown. If the jumper is
not installed, the controller senses an open circuit and will switch OFF. Your controller comes with the
jumper installed and it should only be removed when a sensor or pushbutton timer is installed.
Wire jumper installed for use
WITHOUT optional Occupancy
Sensor (PIR)