INSTALLATION AND OPERATION MANUAL SolahartXXXBLK – AU

INSTALLATION AND OPERATION MANUAL SolahartXXXBLK – AU

For additional information see the relevant datasheet of the module provided at www.solahart.com.au.

PRODUCT LINE

Solahart300BLK

Solahart305BLK

Solahart310BLK

Solahart315BLK

Type

Q.ANTUM

Q.ANTUM

Q.ANTUM

Q.ANTUM

Area [m²]

1.67

1.67

1.67

1.67

Frame height [mm]

32

32

32

32

Weight [kg]

18.5

18.5

18.5

18.5

Max. system voltage V

SYS

 [V]

1000

1000

1000

1000

Max. reverse current [A]

20

20

20

20

Permissible temperature range

–40 °C to +85 °C (–40 °F to +185 °F)

Junction box protection class

IP67 with bypass diode

Connector protection class

IP68

IP68

IP68

IP68

Fire protection class

C

C

C

C

Max. test load push/pull

 

[Pa]

1

5,400 / 4,000

5,400 / 4,000

5,400 / 4,000

5,400 / 4,000

Max. design load push/pull [Pa]

1

3,600 / 2,667

3,600 / 2,667

3,600 / 2,667

3,600 / 2,667

Certificates

VDE Quality Tested; CE-compliant; IEC 61215:2016; IEC 61730:2016;  
Application Class II

1

   Test and design load in accordance with IEC 61215:2016, depending on mounting options (see section „2.3  Mounting options“)

Validity

These instructions are only valid for crystalline solar 
modules from the company Solahart. Solahart assumes 
no liability for damage resulting from failure to observe 
these instructions. 

 

Ä

Please observe the wiring and dimensioning of the 
system.

 

Ä

The installer of the system is responsible for compliance 
with all necessary safety regulations during set-up and 
installation.

Solahart assumes no liability on the basis of these 
instructions. Solahart is only liable in the context of 
contractual agreements or in the context of accepted 
guarantees. Solahart accepts no other responsibility for 
the functionality and safety of the modules. 

 

Ä

Please observe the instructions for any other sys-
tem components that may be part of the complete  
solar power system. It may be necessary to carry out a 
structural analysis for the entire project. 

Additional information for the Operator

 

Ä

Please keep this manual for the entire life of the solar 
power system.

 

Ä

Please contact your system supplier for information 
concerning the formal requirements for solar power 
systems.

 

Ä

Please be sure to contact the relevant local authorities 
and energy providers regarding regulations and permit 
requirements prior to installation of the solar power 
system.

Other applicable documents

In addition to this Manual following technical information 
are relevant:

DOCUMENT TYPE

Product data sheet

Packaging and transport information

1 INTRODUCTION

2.1  Technical specifications

2 PLANNING

Fig. 1: 

External dimensions (in mm) and components for Solahart300BLK,  

 Solahart305BLK, Solahart310BLK, Solahart315BLK

EN

DETAIL A

16 mm

Junction box

1670 mm

4 × 

Mounting slots

 (DETAIL A)

Cable with
connectors

Frame

1000 mm

32 mm

8 × Drainage holes

4 × Grounding points ø 4.5 mm

≥1000 mm

150 mm

8.5 mm

24.5 mm

951 mm

345 mm

980 mm

Summary of Contents for Solahart300BLK

Page 1: ...Valid for Australia and New Zealand Solahart300BLK Solahart305BLK Solahart310BLK Solahart315BLK INSTALLATION AND OPERATION MANUAL ...

Page 2: ...y Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations In particular the installer as well as the operator of a module is responsible for compliance with all applicable statutory requirements and regulations Ä Ä Unless otherwise specified by any laws or regulations the following stipulations must be upheld at all times during the installation ope...

Page 3: ... of the system is responsible for compliance with all necessary safety regulations during set up and installation Solahart assumes no liability on the basis of these instructions Solahart is only liable in the context of contractual agreements or in the context of accepted guarantees Solahart accepts no other responsibility for the functionality and safety of the modules Ä Ä Please observe the ins...

Page 4: ...astened to the ground the roof or the façade Forces acting on the module are relayed to the mounting substructure Ensures sufficient rear ventilation of the module Guarantees long term stability Avoid the usage of different metals to prevent contact corrosion Allows for stress free expansion and contraction due to temperature fluctuations Ä Ä Ensure that no mechanical stresses e g caused by vibra ...

Page 5: ...Observe the maximum permitted number of strings as indicated in the specifications provided by the respective string fuse manufacturer and the technical guidelines NOTE When installing different product versions the lowest minimum permitted reverse current load capacity applies Inverters Inverters with or without transformers may be used 2 4 Electrical layout 2 PLANNING Specifications MODULE TYPE ...

Page 6: ...therproof DANGER Risk of fatal injury due to electric shock Ä Ä Do not install damaged modules Ä Ä Inform your distributor of any damages immediately 3 1 Safety and transport 3 INSTALLATION NOTE Module damage may occur Ä Ä Never lift or move the module with the connection cables or junction box Ä Ä Carry modules upright and horizontally as shown NOTE Module damage may occur Ä Ä Never step on modul...

Page 7: ...ry insulated tools Ä Ä Do not carry out the installation alone Only install undamaged modules and components Ä Ä Do not modify the module e g do not drill any additional holes 3 2 Preparation of installation 3 INSTALLATION Ä Ä Maintain an interval of at least 10mm between two modules along the short side and 5 mm along the long side 10 mm 5 m m EU Option 2 Ä Ä Install the module at the 4 mounting ...

Page 8: ...n Ä Ä Be sure to observe the specified time intervals after switching off the inverter High voltage components need time to discharge DANGER Risk of fatal injury due to electric shock Ä Ä Never open the junction box Ä Ä Change of bypass diodes is only allowed by qualified and trained personnel in disconnected and covered state DANGER Risk of fatal injury due to electric shock Ä Ä Never touch live ...

Page 9: ...k Ä Ä Ensure that all electrical components are in a proper dry and safe condition Ä Ä Standard wiring with a return cable Inverter EN 4 3 Connection of modules 4 ELECTRICAL CONNECTION Ä Ä Ensure that all necessary safety and functional tests have been carried out according to current industry standards NOTE Module damage may occur Ä Ä Ensure that the plug connections are secured away from any wat...

Page 10: ...snow loads etc Ä Ä During the inspections it has to be checked that the components are secure undamaged and clean Cleaning WARNING Risk of injury due to hot and live modules Ä Ä Only clean modules that have cooled down Ä Ä Do not carry or wear any electrically conductive parts WARNING Risk of falling due to unsecured access Ä Ä Never access the installation area alone or without taking adequate se...

Page 11: ...o Geumwang Eup Eumseong gun ChungCheongbuk do Korea 369 901 LICENSE HOLDER AND IMPORTER SOLAHART INDUSTRIES PTY LTD 1 Alan St Rydalmere NSW 2116 Australia Subject to change without notice Hanwha Q CELLS Installation Manual SolahartXXXBLK_2018 10_Rev01_AU ...

Reviews: