INSTALLATION AND OPERATION MANUAL SolahartXXXBLK – AU

INSTALLATION AND OPERATION MANUAL SolahartXXXBLK – AU

13

12

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Block off the installation zone.

 

Ä

Keep children and unauthorized 
individuals away from the solar power 
system.

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Ensure that modules and tools are not 
subject to moisture or rain at any time 
during installation.

WARNING

! Risk of injury due to falling mod-

ules!  

 

Ä

Secure modules during installation. 

 

Ä

Do not install modules in windy or wet 
weather. 

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Only use dry, insulated tools. 

 

Ä

Do not carry out the installation alone.

• 

Only install undamaged modules and  
components.

 

Ä

Do not modify the module (e.g. do not 
drill any additional holes).

3.2  Preparation of installation

3 INSTALLATION

 

Ä

Maintain an interval of at least 10 mm 
between two modules along the short 
side and 5 mm along the long side.

10 mm

5 mm

EU

Option 2:

 

Ä

Install the module at the 4 mounting 
points, see Fig. 2, p. 7.

 

Ä

Tighten clamps according to  
manufacturer’s instructions.

NOTE

! Module damage may occur!

 

Ä

Do not subject modules to mechanical 
tension. Max. torsion 10 mm/m.

Option 3:

 

Ä

Install the module using mounting 

profiles, seeFig. 2, p. 7.

Option 1:

 

Ä

Fasten the module with 4 clamps  

in the specified clamping range, 

 

see Fig. 2, p. 7. 

 

Ä

Tighten clamps according to  
manufacturer’s instructions.

3.3  Module installation

3 INSTALLATION

Summary of Contents for Solahart300BLK

Page 1: ...Valid for Australia and New Zealand Solahart300BLK Solahart305BLK Solahart310BLK Solahart315BLK INSTALLATION AND OPERATION MANUAL ...

Page 2: ...y Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations In particular the installer as well as the operator of a module is responsible for compliance with all applicable statutory requirements and regulations Ä Ä Unless otherwise specified by any laws or regulations the following stipulations must be upheld at all times during the installation ope...

Page 3: ... of the system is responsible for compliance with all necessary safety regulations during set up and installation Solahart assumes no liability on the basis of these instructions Solahart is only liable in the context of contractual agreements or in the context of accepted guarantees Solahart accepts no other responsibility for the functionality and safety of the modules Ä Ä Please observe the ins...

Page 4: ...astened to the ground the roof or the façade Forces acting on the module are relayed to the mounting substructure Ensures sufficient rear ventilation of the module Guarantees long term stability Avoid the usage of different metals to prevent contact corrosion Allows for stress free expansion and contraction due to temperature fluctuations Ä Ä Ensure that no mechanical stresses e g caused by vibra ...

Page 5: ...Observe the maximum permitted number of strings as indicated in the specifications provided by the respective string fuse manufacturer and the technical guidelines NOTE When installing different product versions the lowest minimum permitted reverse current load capacity applies Inverters Inverters with or without transformers may be used 2 4 Electrical layout 2 PLANNING Specifications MODULE TYPE ...

Page 6: ...therproof DANGER Risk of fatal injury due to electric shock Ä Ä Do not install damaged modules Ä Ä Inform your distributor of any damages immediately 3 1 Safety and transport 3 INSTALLATION NOTE Module damage may occur Ä Ä Never lift or move the module with the connection cables or junction box Ä Ä Carry modules upright and horizontally as shown NOTE Module damage may occur Ä Ä Never step on modul...

Page 7: ...ry insulated tools Ä Ä Do not carry out the installation alone Only install undamaged modules and components Ä Ä Do not modify the module e g do not drill any additional holes 3 2 Preparation of installation 3 INSTALLATION Ä Ä Maintain an interval of at least 10mm between two modules along the short side and 5 mm along the long side 10 mm 5 m m EU Option 2 Ä Ä Install the module at the 4 mounting ...

Page 8: ...n Ä Ä Be sure to observe the specified time intervals after switching off the inverter High voltage components need time to discharge DANGER Risk of fatal injury due to electric shock Ä Ä Never open the junction box Ä Ä Change of bypass diodes is only allowed by qualified and trained personnel in disconnected and covered state DANGER Risk of fatal injury due to electric shock Ä Ä Never touch live ...

Page 9: ...k Ä Ä Ensure that all electrical components are in a proper dry and safe condition Ä Ä Standard wiring with a return cable Inverter EN 4 3 Connection of modules 4 ELECTRICAL CONNECTION Ä Ä Ensure that all necessary safety and functional tests have been carried out according to current industry standards NOTE Module damage may occur Ä Ä Ensure that the plug connections are secured away from any wat...

Page 10: ...snow loads etc Ä Ä During the inspections it has to be checked that the components are secure undamaged and clean Cleaning WARNING Risk of injury due to hot and live modules Ä Ä Only clean modules that have cooled down Ä Ä Do not carry or wear any electrically conductive parts WARNING Risk of falling due to unsecured access Ä Ä Never access the installation area alone or without taking adequate se...

Page 11: ...o Geumwang Eup Eumseong gun ChungCheongbuk do Korea 369 901 LICENSE HOLDER AND IMPORTER SOLAHART INDUSTRIES PTY LTD 1 Alan St Rydalmere NSW 2116 Australia Subject to change without notice Hanwha Q CELLS Installation Manual SolahartXXXBLK_2018 10_Rev01_AU ...

Reviews: