8. Checking the accuracy
Check accuracy of the SOLA iOX5 before each
measurement.
> Before starting the check let the device acclimate to
the environmental conditions.
8.1 Checking the accuracy of the vertical plumbing
Mount the laser onto a tripod in a 5-10 m high room
(e.g. staircase).
> Switch-on the iOX5.
> Mark the vanishing point 1 on the ceiling and the
plumbing point L on the floor (with a target).
> Rotate the IOX5 by 180° and align it directly to the
marking L on the ground using the plumbing point.
> Mark the vanishing point 2 on the ceiling.
> Measure the difference d between 1 and 2 .
The accuracy of the plumbing can be calculated as
follows:
G = 10 x d
H
G ... the plumbing accuracy (mm)
d ... difference between the ceiling vanishing points (mm)
H ... room height in (m)
If G is greater than 6 mm, the device must be readjusted.
In this case, consult your dealer.
8.2 Checking the accuracy of the vertical line
> Attach a plumb line as close as possible possible to a
3m high wall.
> Mount the iOX5 onto a tripod at a height of approx. 1.2 m.
> Position the device approx. 3 m in front of the plumb line.
> Switch on the iOX5 and project the vertical laser line
onto the plumb line.
If the deviation is greater than 4 mm, the device must be
readjusted. In this case, consult your dealer.