50
EN
NOTE
Using the >PULSE< mode can save energy and extend battery life by up to 60 %,
if a particularly good visibility of the laser lines is not required.
7.1.3 Creating inclinations beyond the range of the automatic leveling
On:
> Switch off the IOX5 (move the sliding switch to the OFF position)
> Press and hold the >MODE< button for 4 sec. -> display >PULSE< will be lit.
To indicate that the self-leveling is switched off, the lines will blink every 4 seconds.
Off:
> Press and hold the >MODE< button for 4 sec. -> display >PULSE< will be off.
NOTE
If the laser line is not projected vertically to the surface, uneven areas can lead to
erroneous measurement results.
> Make sure that the laser line is projected vertically to the wall or to the detection
surface.
7.2 SOLA Li-Ion battery, charging station & charger
Before the initial startup, the SOLA Li-Ion battery must be fully charged.
> Plug the charger plug into the charging port of the Li-Ion Charger
> Connect the SOLA Li-Ion battery charger to a socket-outlet
> Insert the SOLA Li-Ion battery in the correct position.
> Depending on the charge state and the environmental conditions the charging time
will be between 3 and 5 hours
> After 10 charging cycles the battery will reach its full capacity.
> Ideally, the battery should always be fully charged. In urgent cases, the battery
can be removed from the charging station before the charging process has been fully
completed. This does not adversely affected the service life of the battery (no memory
effect).