![Sol GreenWay GRNWY-125 Installation And Owner'S Manual Download Page 10](http://html.mh-extra.com/html/sol/greenway-grnwy-125/greenway-grnwy-125_installation-and-owners-manual_1312773010.webp)
10 GreenWay™ installation & operation manual 0410 MKTG-IM-GREEN-002
Solar Light System Test
Once all of the wires have been clicked together and the batteries are installed, perform a diagnostic test.
Press the “PUSH TO TEST” Button. This will indicate to the CPU to turn on the LED Luminaire(s) and
operate the lights at full intensity for 5 minutes. Several diagnostic LEDs will turn on & remain on for several
seconds. This is normal.
FIGURE 15
aiSUN™ SYSTEM TEST
Troubleshooting and Diagnostic LEDs
If the LED Luminaire turns on to full brightness, system operates OK and will automatically turn on & off with
sunset and sunrise.
If the LED Luminaire does not turn on as described, follow the Diagnostic LED table (below) to troubleshoot
the system.
If LED Luminaire does not turn on AND no Diagnostic LEDs are on, aiSUN™ is not powered, check battery
and fuse connections.
FIGURE 16
aiSUN™ TROUBLESHOOTING