GEN Start Signal (Two-Wire)
•
The signal comes from a normally open relay that closes when the Gen
Start state is active
CANbus & RS485
•
To connect batteries to the Sol-Ark L12K-Tr via RJ45, you need to splice
the end connecting to the Sol-Ark L12K-Tr
•
Use the middle two conductors
•
RS485 is SunSpec draft 4 (will not work with draft 3)
Wi-Fi Antenna (Dongle)
Remote monitoring and software updates require an internet connection through the Wi-Fi dongle
Limiter Sensors (CT Sensors)
Diagram Below
•
Install sensors on incoming electrical service wires on L1 and L2 Limited to Home Mode (meter zero) and Peak
Shaving Modes require CT sensors
•
CT winding default ratio is 2000:1; however, this ratio is programmable
•
To ensure the sensors will fit, please check the wire size before ordering
Limiter Sensor Diagram
If CT data is wrong, reverse
CT direction and point the
arrow towards the grid