Using the Radian IS
Chapter 4
RADIAN™IS
45
The following are the guidelines for setting schedules:
•
You can schedule data collection for up to seven days in a
one-week period, with up to 35 sessions per day.
•
The scheduler operates perpetually (For example, if an
event is scheduled to occur on a Monday, this event is
serviced every Monday that the system is in operation).
•
Start and stop times must be provided with a resolution of 1
minute.
•
The minimum time interval per data collection session is 5
minutes (300 seconds).
•
If you do not provide file names in advance, a unique file
name is automatically generated for each set of recorded
logs (see Table Auto-Generated File Name Convention, on
Page 49).
•
Only one schedule can be active at any time.
•
If there is sufficient time between sessions, the Radian IS
will power off to conserve power (See Section 4.1, Power
Supply and Control, Page 28).
•
When setting schedules, you may not specify overlapping
time intervals. All scheduled entries rely on day of the
week and time references.
4.5.2
Defining Data to be Collected
You can define what type of information should be collected
during a data collection session by using tools available in the
Sokkia Planning software to create configurations for the Radian
IS. The following sections give an overview of using
configurations. For more information, refer to your Planning
Reference Manual.