5.4.2 Edit Options
22
Click
on system management interface to enter edit options setting interface.
A. Click
to enter production date
Date format
and expiration date format setting.
New format
Note: six common date formats default,
forty-four more formats addable for user.
The six default date formats not editable
Edit format
and cannot be deleted.
Delete format
Click
or
in date format setting
interface, new or edit date format, date
format edit interface appears.
Note:
Year/Month/Hour have 3 hex options:
decimal/26 hex/36 hex, before operating
first need to select hex and then the date
format.
Hex switch
1.
Year, options are:
---4-digit,
---last 2 digit,
---last 1 digit
2.
Month, options are:
---digit,
---Jan to Sep is 1-9, and then O/N/D,
---abbreviations,
---full English
3.
Hour, options are:
--24 hours system,
---12 hours system
B. Click
to enter special time
setting.
Date transition
time setting
see Appendix 1: Terms and
Definitions 4, 5.
Pre-zero in
date/time
Special time
setting
1) Date transition time setting: system default normal zero
o’clock as date transition time to next date,
users can set different time as date transition time.
2) Pre-zero in date/time: four options: OFF, empty preposition, empty postposition, centered without zero.
(e.g. 2012/05/09, 2012/_5/_2, 2012/5_/2_, 2012/5/2).
C. Click
to enter counter
setting .
Productio
n counter
Counter
pre-zero
Counter alarm
Counter reset
Counter setting
1) Production counter: setting extent: 0~99999999.
2) Pre-zeros: four options: OFF, empty preposition, empty postposition, centered without zero
(e.g. 0001,
1, 1
, 1).
3) Counter alarm: ON or OFF option. When counter alarm is turned ON, the machine will stop printing,
sound alarm and prompt message that print number reaches maximum value.
4) Counter reset: ON or OFF option. All counters will start from initial values if the counter reset is turned
ON. The printing value will continue with the last one if the counter reset is turned OFF.
Summary of Contents for Elfin IC