background image

Handbuch / Manual  

21 

9  ARCNET Interfaces 

9.1  Coaxial Interface (-K) 

Connector type:

 BNC Socket, decoupled from device housing 

9.2  RS-485/EIA-485 Interface (-R) 

Important:

 To maintain the electro-magnetic compatibility (EMC) the 

shield of the cable connected to the D-sub DE9M plug must be solidly 
attached to the screen of the connector. 

Connector type:

 D-sub DE9F socket 

Pin assigment 

Pin 

Marking 

Description 

 

1,5 

GND_RS  Reference potential, 

supply 

DATA-A 

Data line A 

DATA-B 

Data line B  

2, 6-8 

NC 

reserved 

+5V_RS 

Is5 V Supply for 
RS485 Interface. The 
maximum current must 
not exceed 25 mA. 

Shield 

AGND 

Shield 

 
Insulation is implemented between RS485 pins 1 to 9 on one side and the 
shields of RS485 and USB on the other side. 

 

 

 

 

 

Summary of Contents for SH ARC-USB

Page 1: ...Handbuch Manual 1 ...

Page 2: ...Handbuch Manual 2 ...

Page 3: ...igen 9 4 ARCNET Schnittstellen 11 4 1 Koaxiale Schnittstelle K 11 4 2 RS 485 EIA 485 Schnittstelle R 11 4 3 RS485AC Schnittstellen RS485AC RJ45 BNC 12 4 4 Twisted Pair Schnittstelle TWP 13 4 5 LWL Schnittstellen LWLSMA LWLST LWLTOS 13 5 Was tun bei Problemen 15 6 Safety Instructions 16 6 1 Warnings and Instructions 16 6 2 Installation 16 6 3 To ensure electro magnetic compatibility 16 6 4 Water hu...

Page 4: ...IA 485 Interface R 21 9 3 RS485AC Interface RS485AC RJ45 BNC 22 9 4 Twisted pair Interface TWP 23 9 5 Fiber Optic Interfaces LWLST LWLSMA LWLTOS 23 10 Troubleshooting 24 11 Appendix 25 11 1 Technical Specifications 25 11 2 CE Declaration of Conformity 27 11 3 Contact 28 11 4 Warranty 28 11 5 Support 28 11 6 Order information 29 11 7 Literature 29 ...

Page 5: ...it a An den ARCNET Anschlüssen dürfen nur geschirmte Kabel mit geschirmten Steckern angeschlossen werden b Es dürfen nur Bitraten verwendet werden die von SOHARD für das gewählte Übertragungsverfahren spezifiziert sind c Bei modularen Geräten dürfen nur originale Schnittstellenmodule von SOHARD verwendet werden d PC Einbau Karten dürfen nur in PCs mit durchgehender Schirmung verwendet werden Unbel...

Page 6: ...terner Spannungsversorgung müssen geerdet sein Spannungsfreiheit ist gegeben wenn das Netzkabel vom Gerät abgezogen wird Geräte mit Netzanschluss dürfen nur mit Netzkabel mit Schutzleiter angeschlossen werden Die Versorgungskabel für Kleinspannungsgleichstromgeräte 24 VDC dürfen eine Länge von 30 m nicht überschreiten 1 9 Behebung von Schäden Geräte mit Gehäuse dürfen nur von SOHARD geöffnet werde...

Page 7: ...se oder die elektrischen Bauteile beschädigt sind oder e das Gerät nicht ordnungsgemäß funktioniert 1 10 Umkonfiguration von Schnittstellenmodulen Die Umkonfiguration von Schnittstellenmodulen darf nur von SOHARD vorgenommen werden ...

Page 8: ... Bauform Sie ist auch als PC Einbau Karte für die Verwendung in Low Profile PCs erhältlich 3 Inbetriebnahme 3 1 Änderung von Busterminierung und Sendeleistung Bitte beachten Sie dass das Gerät nur von SOHARD geöffnet werden darf siehe Sicherheitshinweise Bitte senden Sie ein Gerät ein falls Sie die Aktivierung des Bus Abschlusswiderstandes bei kupfergebundenen ARCNET Schnittstellen oder eine Änder...

Page 9: ...eunterseite haben lassen sich nur mit entsprechenden Treibern in Betrieb nehmen Geräte deren Seriennummer mit einer 5 beginnt benötigen die Treiberversion 4 5 Bei Verwendung des Treibers wird die Karte automatisch vom Betriebssystem erkannt und im System integriert 3 4 LED Anzeigen LED Beschreibung POWER grün Zeigt an dass die Versorgungsspannung anliegt USB grün Blinkt wenn die Firmware geladen w...

Page 10: ...Aktivität an STATUS rot Zeigt Zugriffe auf den ARCNET Controller an Die Anordnung von LEDs und Koaxial Schnittstelle ist bei der Low Profile PC Einbaukarte SH ARC USB K LP identisch Frontblende SH ARC USB außer SH ARC USB K Frontblende SH ARC USB K ...

Page 11: ...dete Kabel über einen Schirm verfügen der möglichst niederimpedant mit dem Gehäuse des D Sub Steckers verbunden werden muss Anschluss D Sub Buchse 9 polig Steckerbelegung Pin Bezeichn Bedeutung 1 5 GND_RS Bezugspotential Masse Versorgungsspannung 3 DATA A Datenleitung A 4 DATA B Datenleitung B 2 6 8 NC Reserviert 9 5V_RS Galvanisch getrennte 5 Volt für RS 485 Schnittstelle Die maximale Belastung d...

Page 12: ...ung stellen sich wie folgt dar Der resultierende Abschlusswiderstand beträgt dabei ca 114 Ohm 4 3 RS485AC Schnittstellen RS485AC RJ45 BNC Wichtiger Hinweis Zur Erhaltung der elektromagnetischen Verträglichkeit EMV muss das verwendete Kabel über einen Schirm verfügen der möglichst niederimpedant mit dem Steckergehäuse verbunden sein muss Anschluss RJ45 Buchse bzw BNC Buchse ...

Page 13: ...omagnetischen Verträglichkeit EMV muss das verwendete Kabel über einen Schirm verfügen der möglichst niederimpedant mit dem Steckergehäuse verbunden werden muss Anschluss RJ45 Buchse Belegung kompatibel zur SH ARC 66 von SOHARD Steckerbelegung Pin Transceiver Pin Bedeutung 4 PH_A Datenleitung A 5 PH_B Datenleitung B 1 3 6 9 unbeschaltet Reserviert 4 5 LWL Schnittstellen LWLSMA LWLST LWLTOS Anschlu...

Page 14: ...LWLSMA 2 FSMA Buchsen je eine für Senden und Empfangen TX muss mit RX bzw RX mit TX der Gegenstelle verbunden werden Anschluss TOSLINK Toshiba spezifische Buchse TODX296 für TX und RX Leitung Verwendbare Stecker TOCP200Q TOCP200X CF 2071 ...

Page 15: ...iche Ursachen Treiber nicht geladen oder nicht installiert Hardware defekt LED ACTIVITY zeigt Rekonfigurationen an Mögliche Ursachen Es ist nur ein Knoten im Netz Das Netzwerk ist nicht korrekt terminiert Bei RS 485 Verbindungen sind DATA A und DATA B vertauscht LED ACTIVITY leuchtet nicht Mögliche Ursachen Der ARCNET Controller arbeitet mit einer unzulässigen Bitrate Software arbeitet fehlerhaft ...

Page 16: ...3 To ensure electro magnetic compatibility a Only attach shielded cables and shielded connectors to the ARCNET connector b Only use bit rates which are specified by SOHARD for the actual transfer mode c Only use original interface modules by SOHARD for modular cards d PC cards may only be used in PC casings with intact and complete shielding Unused slots must be closed appropriately 6 4 Water humi...

Page 17: ...er cords with protective earth conductor Supply cables for devices with 24 VDC power supply must not exceed the length of 30 meters 6 9 Repair Device casings must only be opened by SOHARD This also applies to the interface modules and the corresponding slots in the casing The device must only be repaired by SOHARD The device must be sent for inspection or repair to SOHARD if a the power supply con...

Page 18: ...ulse signaling via coaxial cables SH ARC USB K has is more compact and lighter than the other devices of the product family It is also available as a PC card for use in low profile PCs 8 Commissioning 8 1 Switching bus termination and transmission power Please keep in mind that the device may only be opened by SOHARD cf Safety Instructions Please send the device in if you need the bus termination ...

Page 19: ...ed using the respective driver versions Devices with a serial no starting by 5 need the driver version 4 5 When SOHARD drivers are applied the device will be automatically detected by the system 8 4 LED Indicators LED Description POWER green Indicates presence of power supply from USB USB green Flashing when firmware download is complete and controller is running Slow flashing approx 1 2 Hz USB In...

Page 20: ...Handbuch Manual 20 accessed The positions of the LEDs and the BNC socket of the SH ARC USB K and the SH ARC USB K LP correspond Front panel of SH ARC USB except K Front panel of SH ARC USB K ...

Page 21: ... DE9M plug must be solidly attached to the screen of the connector Connector type D sub DE9F socket Pin assigment Pin Marking Description 1 5 GND_RS Reference potential supply 3 DATA A Data line A 4 DATA B Data line B 2 6 8 NC reserved 9 5V_RS Isolated 5 V Supply for RS485 Interface The maximum current must not exceed 25 mA Shield AGND Shield Insulation is implemented between RS485 pins 1 to 9 on ...

Page 22: ...etic compatibility EMC the shield of the cable connected to the RJ45 plug must be solidly attached to the shield of the connector Connector type RJ45 socket RJ45 BNC socket BNC Pin assignment RJ45 Pin Marking Description 4 PHASE B Data line B 5 PHASE A Data line A 1 3 6 9 NC Reserved The center core of a BNC socket is PHASE A its shield is PHASE B ...

Page 23: ...ransceiver Pin Description 4 PH_A Data line A 5 PH_B Data line B 1 3 6 9 NC Reserved 9 5 Fiber Optic Interfaces LWLST LWLSMA LWLTOS LWLST connectors 2 x ST BFOC bayonet for transmission and reception respectively Connect TX to RX and vice versa LWLSMA connectors 2 x FSMA threaded for transmission and reception respectively Connect TX to RX and vice versa TOSLINK connector TOSHIBA specific socket T...

Page 24: ...red USB hub LED ARCNET not flashing Possible causes Driver not started or not installed Defective hardware LED ACTIVITY indicating RECON Possible causes Single node operation Invalid termination DATA A and DATA B interchanged or otherwise wrongly connected LED ACTIVITY inactive Possible causes Incorrect bit rate setting Software misoperation Defective hardware LED RESET continuously lighting or sp...

Page 25: ...8 1 2 5 W Logic protecting dipulse transceiver against invalid bit rate and transmission mode 19 531 39 063 78 125 156 25 312 5 625 kbit s 1 25 2 5 5 10 Mbit s 11 1 3 USB Functionality Compatibility Power supply USB 1 1 USB 2 0 5 V 500 mA max 11 1 4 Coaxial Interface K Data rate Input impedance Input threshold Line termination Output peak voltage Output signal shape Cabling Connector 2 5 Mbit s 10...

Page 26: ...ion Output peak voltage Ouput pulse shape Cabling Connector 2 5 Mbit s 10 Mbit s RJ45 120 ohm BNC 93 ohm Internal termination disabled by default 2 5 V typ Bipolarly alternating rectangular pulses RJ45 twisted pair wire with Z 120 ohm BNC coaxial cable with Z 93 ohm is recommended RJ45 Shielded RJ45 socket BNC BNC socket 11 1 7 Twisted pair Interface TWP Data rate Bus termination Output peak volta...

Page 27: ... 1 9 Optic Fiber Interface TOSLINK LWLTOS Data rate Optical input power Peak output power Peak power wavelength Connector 19 5 kbit s 2 5 Mbit s min 31 dBm max 14 dBm min 20 dBm max 14 dBm when coupled in 200 µm fiber four grades selectable very low low default medium high 800 nm TODX296 mating with CF 2071 TOCP200Q and TOCP200X 11 2 CE Declaration of Conformity The SH ARC USB product family meet ...

Page 28: ...49 0 911 97341 10 eMail info sohard de 11 4 Warranty Warranty is granted by SOHARD Embedded Systems according to our General Terms and Conditions 11 5 Support Read these instructions carefully before taking the device into operation Before contacting us please make sure the information you require is not given by this manual or by the FAQs on our website ...

Page 29: ...WLTOS 0 0195 2 5 optical TODX296 TOSLINK multi mode fibers SH ARC USB R 0 0195 10 RS 485 EIA 485 D sub twisted pair cable SH ARC USB RS485AC BNC 2 5 10 RS485AC BNC coaxial cable RG 62 SH ARC USB RS485AC RJ45 2 5 10 RS485AC RJ45 twisted pair cable SH ARC USB TWP 2 5 sine dipulse RJ45 twisted pair cable 1 Device with low profile slot bracket for use in low profile PCs 11 7 Literature Reference Docum...

Page 30: ...Handbuch Manual 30 ...

Page 31: ...Handbuch Manual 31 ...

Page 32: ...Handbuch Manual 32 ...

Reviews: