Softrail AI3050S Sargas Manual Download Page 5

 

AI3050S Sargas AEI Reader

 

 

   

 

1  

March 25, 2018  

 

1. BRIEF OVERVIEW 

The AI3050S reader system was developed to provide an easy solution for installing an AEI 
reader beside a track.  The AI3050S AEI Reader houses a Sargas AEI Reader in a 
weatherproof enclosure.  This enclosure contains a 120 VAC to 12 VDC and a 120 VAC to 5 
VDC power supplies. 

The Sargas reader has a network interface and is capable of multiplexing between two 
antennas (one on each side of track).  It also has two digital inputs. 

The 120 VAC to 5 VDC power supply is used to supply power to the Sargas reader.  The 120 
VAC to 12 VDC power supply can be used to supply power to external sensors such as a 
presence detector or switch (turnout) position monitor. 

  

2. EQUIPMENT INSTALLATION 

2.1. Antenna Installation 

One or two external antennas can be connected to the AI3050S reader.  Normally two 
antennas are connected and are mounted on poles on opposite sides of the track.  They can 
be mounted across from each other (+/- 5 feet) and 11 feet from the center of the rail.  The 
center of each reader antenna should be 3 ½ feet above the top of the rail.  The antennas 
should be pointing toward the track. 

Please note for train speeds less than 25 mph there is a great deal of tolerance in the 
placement of the antennas.  They can be mounted vertically from one foot to 6 feet above the 
top of the rail and can be positioned 8 to 12 feet from the center of the rail. 

A conduit should be placed under the rail for the coaxial cable running from the controller to 
the antenna on the opposite side of the track. 

2.2. Reader Installation 

There are five main components in the AI3050S reader’s enclosure.  These are: 

  Sargas AEI RF Reader 

  Ethernet Terminal Block 

  Sensor Terminal Block 

  12 VDC Power Supply  

  5 VDC Power Supply  

 
Figure 1 shows the layout of the components. 

Summary of Contents for AI3050S Sargas

Page 1: ...AI3050S Sargas AEI Reader March 25 2020 Copyright 2018 Softrail All rights reserved...

Page 2: ...argas AEI Reader ii March 25 2018 Softrail 1098 Venetia Road Eighty Four PA 15330 Tel 888 872 4612 toll free US and Canada only Tel 724 942 1473 Fax 724 942 1480 E mail aei signalcc com Web Page www a...

Page 3: ...EF OVERVIEW 1 2 EQUIPMENT INSTALLATION 1 2 1 Antenna Installation 1 2 2 Reader Installation 1 3 Sargas Configuration Software 7 4 QT50R Presence Radar 8 5 Antenna and M GAGE Q7LMEB Installation 9 6 Sw...

Page 4: ...Ethernet Terminal Block 4 Figure 4 Sensor Terminal Block 5 Figure 5 Sargas URL 7 Figure 6 Sargas Status Display 7 Figure 7 Sargas Network Settings 8 Figure 8 QT50R Presence Radar 9 Figure 9 Back of th...

Page 5: ...be connected to the AI3050S reader Normally two antennas are connected and are mounted on poles on opposite sides of the track They can be mounted across from each other 5 feet and 11 feet from the ce...

Page 6: ...AI3050S Sargas AEI Reader 2 March 25 2018 Figure 1 AI3050S Reader Layout Ethernet Terminal Block AC Power Supplies 12 VDC 5 VDC Sensor Terminal Block Sargas AEI RF Reader...

Page 7: ...ure 2 Cable Connections Power is connected to the three terminals located under a clear plastic protective cover near the bottom left side of the mounting plate in the controller s enclosure see Figur...

Page 8: ...erminal connections Signal Wire Color Terminal TX White Green Stripe 1 TX Green 2 RX White Orange 3 RX Orange Stripe 6 Figure 3 Ethernet Terminal Block Sensor connections are made through the sensor t...

Page 9: ...etween terminals 1 and 3 digital input 0 will be reported as high and between 5 and 7 digital input 1 will be high If there is not a contact closure between the respective terminals the digital inputs...

Page 10: ...rs the following table shows the wiring connections Terminal Description Sensor Wire Color Sensor Pin 1 or 5 12 VDC Brown 1 2 or 6 Ground Blue 3 3 or 7 Digital Inputs Black 4 4 or 8 Digital Outputs Gr...

Page 11: ...he URL of the reader is printed on the side of the module In Figure 5 the Sargas URL is Sargas 45b229 If the Sargas Reader is directly connected to a PC add Iocal to the URL When prompted enter web as...

Page 12: ...of the rail on the same pole as the controller The front of the radar should be facing the track and pointing up at a 20 degree angle In the back of the unit there is a set of 8 dipswitches To open th...

Page 13: ...l A minimum of a 1 inch diameter conduit should be placed under the rail for the coaxial cable running from the controller to the antenna on the opposite side of the track Please note that the tags an...

Page 14: ...AI3050S Sargas AEI Reader 10 March 25 2018 Figure 9 Back of the Antenna Figure 10 Near Antenna with M GAGE Presence Detector M Gage Sensor...

Page 15: ...ailroad switch by monitoring the position of the railroad switch s throw rod A rod attached to the limit switch will be mounted so that it will move when the railroad switch s throw rod changes positi...

Page 16: ...hat you check our web page at www aeitag com to insure that you have the latest maintenance release of the program Technical support is free for the first year after purchase A maintenance agreement c...

Page 17: ...nstallation 1 9 installation antenna 1 M GAGE 9 QT50R 8 reader 1 M GAGE 6 9 network configuration 7 connection 4 presence detector 6 radar 8 Q7LMEB 6 QT50RAF 6 8 reader installation 1 Sargas reader 7...

Reviews: